MAINTENANCE AND CLEANING
1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can "see". At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
PULL UP TO
REMOVE PROBE
RESERVOIR
CLEAN THE
WATER LEVEL
PROBE
///////////////////////////////////////////
CAUTION: THE TIP IS
MADE OF GLASS
//////////////////////////////////////////
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
3. The bearing in the breaker should also be
checked at least two times per year.
Electrical shock hazard.
Electrical shock can
cause personal injury.
Disconnect power before
beginning to service
components.
August 1993
A. Check the bearing by:
removing the ice chute cover
unscrewing the ice sweep
removing the water shed
unscrewing the breaker cover.
unscrewing the auger stud
Inspect the assembly, looking for wear.
ICE LEVEL SENSORS:
SLIDE TO REMOVE
CLEAN THE
LIGHT SENSORS
See Removal and Replacement to replace
bearing or seals. Reverse to reassemble.
4. Check and tighten all bolts and screws.