Download "Smart Life" app from Google play and app store:
Considering battery usage, RF data updates every 20 minutes. If shorten interval, pls use USB power and remove batteries. Follow B05, B06 operation.
Pls remove batteries when USB power is working.
NO | Icon | Description |
A | Turn ON/OFF | |
B |
| |
C |
| |
B |
| |
D |
|
Power on state, press to set minute.
Second press to set hour.
Third press to set week.
Press to change value.
Press again to confirm.
Power on state, long press for 3-5 seconds to do holiday mode setting. Press or to change "OFF" to "ON". Then press to switch days and temperature, press , to change value. Press again to confirm. If you want to close holiday mode, press
6 times period setting: 5+2 days(factory default),6+1 days, 7 days
Long press " " 3-5 seconds to do Programmable Mode Setting. Short press " " to switch and confirm. Press " " and "" to adjust value.
Power on state, long press "" 3-5 seconds to enter into first time period then set hour. press "" and " " to adjust hour, short press " " to confirm then set minutes, press "" and "" to adjust minutes, press "" to confirm then enter into temperature setting, press "" and "" to adjust value. Pls follow the steps of first time period to set second time period, thirdly time period......
After finish setting, stand for about 10 seconds, it will save setting then exit.
Wake up | Out door | Back home | Out door | Back home | Sleep | ||||||
6:00 | 20℃ | 8:00 | 15℃ | 11:30 | 15℃ | 13:30 | 15℃ | 17:00 | 15℃ | 22:00 | 15℃ |
Power off state, long press for 3-5 seconds to do advanced setting. Short press "" to switch and confirm. Press "" and "" to adjust options.
After finish setting, stand for about 5 seconds, it will save setting then exit.
NO | Description | Range | Default |
A1 | Temperature Calibration | -9-+9℃ | 0.5℃ |
A2 | Switching Differential of Built in Sensor | 0.5-2.5℃ | 1℃ |
A3 | Switching Differential of External Sensor | 1-9℃ | 2℃ |
A4 | Children Lock | 0:half lock 1:full lock | 0 |
A5 | Max temp of External Sensor |
| -- |
A6 | Min temp of External sensor (anti-freeze protection) |
| 5℃ |
A7 | Max Temp Setting | 1-10℃ | 5℃ |
A8 | Min Temp Setting | 20-70℃ | 35℃ |
A9 | Descaling function |
| 0 |
AA | Power off Memory |
| 0 |
AB | Weekly Programmable Function | P1: 5+2 days P2: 6+1 days P3: 7 days | P1 |
AC | Factory defaults | Display A o, long press until show the whole screen |
Power off state, long press for 3-5 seconds to do advanced setting. Short press "" to switch and confirm. Press "" and "" to adjust options.
After finish setting, standing for 5 seconds, it will save setting then exit.
Considering battery usage, RF data updates every 20 minutes. If shorten interval, pls use USB power and remove batteries. Follow B05, B06 operation.
NO | Setting Options | Data Setting Function | Factory Default |
B1 | IP code low setting | 00-FF | 00 |
B2 | IP code high setting | 01-FF | 01 |
B3 | IP matching code | Display"55" means IP match successfully. (When receiver is power-on, press thermostat successively) | 00 |
B4 | Sensor state | N1:single built-in sensor N3:both built-in sensor and external sensor. (when receiver with external sensor, this option is automatically recognized and cannot be changed) | N1 |
B05 | Minute interval of RF transmission | 1: 1-30 minutes 2:0 B06 | 20 min. |
B06 | Second interval of RF transmission | 3-30 seconds | 30 s |
Power-on light: green light
Load light/fault light: red light
RF matching light: orange light
(B3 IP matching code) When receiver is power-on, orange light is normally on within 10s. And light off when finish matching. When receiver is power-off, orange light is blinking within 10s.
Wifi matching light: blue light
When power on state, long press receiver button"push" to match wifi. Normally on is EZ mode. Blinking is AP mode. Successive blinking is matching.
RISK OF ELECTRICAL SHOCK
Please arrange professional technician to install the product according to drawings and instructions. Disconnect power supply before making any connection. Contact with components carrying hazardous voltage can cause electrical shock.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the BGL09RF-WIFI that isn't answered in the manual? Leave your question here.