NME654R & FME804R

FOR THE ELECTRICIAN

Connect the electrical power to the unit to the wires
in the junction box at the rear of the machine.
Check the nameplate (located on the back panel)
for the voltage requirements, and for the minimum
circuit ampacity. The machine requires a solid
chassis to earth ground wire.
Connect the ice machine to its own electrical circuit
so it is individually fused. Voltage variation must
remain within design limitations, even under
starting conditions.
GROUND
THE
CHASSIS

CONFORM TO ALL APPLICABLE CODES

TERMINAL STRIP
FOR REMOTE
CONDENSER
ICE MACHINE
JUNCTION BOX
POWER
SUPPLY
There is a separate junction box for the remote
condenser fan motor.
Install an interconnecting wire between the remote
condenser and the junction box at the back of the
ice machine.
The remote condenser must be wired to the ice
machine in accordance with local and national
electrical codes with a minimum of 18 Awg. wire
with an ground bonding wire connected to the
ground screws provided in both the condenser and
machine field wiring boxes. All outdoor wiring must
be in rainproof conduit.
All external wiring must conform to national,
state, and local electrical codes. The use of a
licensed electrician is required to perform the
electrical installation.
January 2000
Page 10
RAIN PROOF
CONDUIT