Advertisement

Quick Links

I N S T R U C T I O N M A N U A L
COMBI
Codes:
COMBI325
COMBI325RODI
COMBI325TR
Available Varitations:
- 325Ltr and 500Ltr tank options
- Water Delivery, Reverse osmosis
with DI, RODI and Mobi™ trolley
with DI
English
INSTR-COMBI
These instructions identifies a risk situation
which could lead to serious injury. MUST
read before operating the COMBI®
tank system.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMBI COMBI325 and is the answer not in the manual?

Questions and answers

Summary of Contents for Streamline COMBI COMBI325

  • Page 1 I N S T R U C T I O N M A N U A L COMBI ™ Codes: COMBI325 COMBI325RODI COMBI325TR Available Varitations: - 325Ltr and 500Ltr tank options - Water Delivery, Reverse osmosis with DI, RODI and Mobi™ trolley with DI English These instructions identifies a risk situation...
  • Page 2: Table Of Contents

    Adjusting the calibration on the controller Maintenance & Replacing Filters TDS Meters Prefilters - Usage and Replacing De-ionising (DI) resin filter Reverse Osmosis Membrane Filters The Pump Disposal of System and Filters Why Streamline® Warranty Information W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 3: General Responsibilities

    General Responsibilities These operating instructions allows you to use the Combi™ tank system safely and efficiently. The instructional booklet must be read before setting up, starting or using your streamline® equipment. It is an integral part of the product itself.
  • Page 4 Pure Water Flow 5.2 Lpm Per Pump 5.2 Lpm Per Pump 5.2 Lpm Per Pump (optimum output) Operating Time Approx. 8hrs per user Approx. 8hrs per user Approx. 8hrs per user W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 5 - Pre Filtration - Reverse Osmosis Membrane - DI Resin vessel - Waste Water Regulator TR Trolley - 100psi Shurflo Pumps - Digital Flow Controller - DI Resin vessel fitted to Trolley W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 6: Electrical Specifications & Safety

    If in doubt, consult a qualified electrician. The correct plug should be fitted by a qualified electrician. VARITECH SYSTEMS Ltd, the manufacturer of STREAMLINE® declines all liability for damage to persons, animals or things caused by faulty or incorrect connection.
  • Page 7: Safety Precautions

    • Do not use the Combi™ with telescopic poles in the vicinity of power lines, junction boxes, power sockets – Please read STREAMLINE® OVA8® operating instructions • Do not attempt to modify the Combi™ as this could cause a safety hazard or system breakdown •...
  • Page 8 Additional protective equipment such as a dust mask, non-skid safety shoes, hard hat or hearing protection may be required depending on the safety regulations in the operator surroundings. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 9 Never use the Combi™ system with a damaged cable. Mechanical Hazards • To avoid all mechanical hazards, ensure the Combi™ system is safely secured in position before filling the water tank. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 10: Operating The Combi™ System

    Combi™ System. Packaging (bags, boxes, nails, tape etc.) should be kept out of reach of children as they may represent a potential hazard. Packaging can be recycled according to your local legislation. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 11: Storage Of Your System

    It is important for all filters to not be allowed to dry out when not in use. Important The unit must be protected from freezing. The following procedures should be followed to protect the unit from bacteria fouling and damage from freezing; W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 12: About Your System

    About your system No Filtration Hose Reel Pump Controller 1 Pump Controller 2 Battery Hatch Outlet 2 Outlet 1 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 13 COMBI ™ COMBI-RODI Hose Reel DI Filter Water Inlet Pressure Reverse Osmosis Waste Adjustment Valve Carbon Filter Sediment Filter Water Inlet Outlet 2 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 14 COMBI-TR Hose Reel Streamline Trolley W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 15 COMBI ™ W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 16 The reverse osmosis (RO) membrane filters remove up to 98% of the impurities in the water, before it reaches the de-ionising (DI) resin filter where the water is polished and reaches a 000ppm result. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 17 8 hours continual usage. Important Only use the Streamline® charger supplied with your Combi™ system. If misplaced, contact your dealer of manufacture immediately. The charger will never over heat. This has a safety function to prevent the battery from over charging.
  • Page 18 Connect the water inlet connection to the mains water via bumper port connection (if supplied) with 10mm pipe. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 19 Ensure that the ‘waste water regulator valve’ for the Reverse Osmosis filter is fully open (turn anti-clockwise). iv. Switch on the mains water, and allow all air to pass through the filter system W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 20 Pure outlet to the hose reel or directly to waterfed pole via mounted Hosereel this is ready for use. ii. Switch the flow controller on by pressing the button. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 21 If you are cleaning windows on a warm day, the rinsing procedure must be done meticulously, as warm, direct sunlight can cause spotting due to insufficient rinsing. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 22: Turning Your Combi™ System Off

    The COMBI™ system is designed for a single or double operator use. Press and hold the button on the STREAMLINE® flow controller, switching off the Shurflo pump ii. Remove all hoses and safely store and wind hoses in. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 23: Malfunctions & Troubleshooting

    Check for any blockages in membrane Raise the calibration on the controller Contact service centre v. Controller flashing ‘BAT’ constantly Plug in battery charger immediately before the battery is flat Contact service centre W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 24: Controller Troubleshooting

    ECOSTREAM® system, start your vehicle engine which will then start the charging process. Adjusting the calibration on the controller The Streamline® controller can automatically shut down the pump automatically This is known as ‘dead-end’ and labelled ‘dE’ on the controller.
  • Page 25 Setting calibration higher than necessary places extra strain on both the pump and the controller in a dead-end situation. This can result in damage to both the pump and your controller. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 26: Maintenance & Replacing Filters

    • Complete a check on all membranes to ensure performance is still acceptable Warning Ensure the Combi™ system is not operating or under pressure when maintenance or filter replacements are being undertaken. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 27: Tds Meters

    2. The TDS meter, which measures the the IN Reverse Osmosis filtered water (out). If the Reverse Osmosis (out) reading is above 40ppm, a replacement RO membrane is needed. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 28 - Sediment prefilter - Carbon Block prefilter Ensure you safely and securing tighten up the housing to ensure the system is safe under operating pressure PRODUCT CODE: KIT02310-CLK W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 29 Ensure you safely and securing tighten up the housing to ensure the system is safe under operating pressure. Warning Disposing of resin beads can create a slippery surface. Care needed to dispose of resin beads effectively. Remove all over spill immediately W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 30 5. Reassemble the stainless steel membrane housing, and clamp back into position be fore attaching the inlet, outlet and waste water hose connections W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 31 The COMBI™ system is classified as special waste. It must be taken apart and divided into uniform sections which should be disposed of according to current legislation. Do not use the components removed as spare parts. All filters are disposable as unharmful general waste. W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 32 • Streamline® is backed by a comprehensive range with massive stocks providing you with a ‘one stop shop’ for all your requirements. Manufatured Checked &...
  • Page 33 This warranty constitutes the exclusive remedy replace normal maintenance items. THIS LIST of any purchaser of a Streamline® unit and is in IS NOT EXHAUSTIVE. lieu of all other warranties, express or implied, including without limitation any implied If Streamline®...
  • Page 34 Notes W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 35 COMBI ™ W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830...
  • Page 36 Hamilton House, 8 Fairfax Road, Heathfield Industrial Estate, Newton Abbot Devon, TQ12 6UD United Kingdom Telephone: +44 (0) 1626 830 830 Email: sales@streamline.systems INSTR-COMBI Visit www.streamline.systems...

This manual is also suitable for:

Combi combi325rodiCombi combi325tr

Table of Contents