Hydrolevel Company HYDROZONE 6000 Series Installation Instructions And Operating Manual

Single zone switching relay

Advertisement

Quick Links

Model 6001
Single Zone
Switching Relay
120 VAC Input
Read these instructions completely before proceeding with the installation. Retain instructions for future reference.
WARNING
Electrical shock hazard. To prevent electrical shock, death or equipment damage, disconnect power supply before installing
or servicing control. Only qualified personnel may install or service this control in accordance with local codes and ordinance
WARNING
Frozen pipes/water damage. Central heating systems are prone to shut down as a result of power or fuel outages,
safety related fault conditions or equipment failure. Installation of freeze protection monitoring or other precautions is recom-
mended for unattended dwellings in climates subject to sustain below-freezing temperatures.
126 Bailey Road • North Haven, CT 06473 • (203) 776-0473 • FAX (203) 764-1711 • www.hydrolevel.com
Installation Instructions and
Operating Manual
• LED INDICATORS
• ZONE FAULT INDICATOR
• AUTOMATIC CIRCULATOR SHORT CYCLE PROTECTION
• AVAILABLE COMMON TERMINAL FOR SMART THERMOSTATS
• TEST BUTTON
• 10 VA TRANSFORMER TO PROVIDE THERMOSTAT POWER
• TWO SPDT RELAYS
• FUSED OUTPUTS WITH SPARES INCLUDED
• EXTRA L2 TERMINAL FOR EASE OF WIRING
Ratings
Output relays .......... 6 Amps per contact
Combined outputs .. 12 Amps
RWC input .............. 24 VAC, 10 VA
Fuses ...................... 16 A, slow blow

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYDROZONE 6000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hydrolevel Company HYDROZONE 6000 Series

  • Page 1 Installation Instructions and Operating Manual Model 6001 • LED INDICATORS Single Zone • ZONE FAULT INDICATOR Switching Relay • AUTOMATIC CIRCULATOR SHORT CYCLE PROTECTION 120 VAC Input • AVAILABLE COMMON TERMINAL FOR SMART THERMOSTATS • TEST BUTTON • 10 VA TRANSFORMER TO PROVIDE THERMOSTAT POWER •...
  • Page 2 MOUNTING INSTRUCTIONS 1. Position the enclosure against a flat wall surface or boiler jacket and mark the top center keyhole location A. 2. Start a screw in the marked location and hang the control on the screw. 3. Add screws to the lower right and lower left mounting holes B and tighten all three screws.
  • Page 3 INDIRECT TANK WIRING FOR PRIORITY WIRING — continued INDIRECT TANK WIRING FOR PRIORITY INDIRECT TANK THERMOSTAT POWER ZONE TEST LOAD 2 LOAD 1 L2 NEUTRAL FACTORY JUMPER 120 VAC L1 HOT INDIRECT CIRCULATOR BOILER CONTROL TERMINAL DESIGNATIONS Low Voltage/Thermostat R 24 VAC for the thermostat R terminal W 24 VAC for the thermostat W terminal C 24 VAC common for powered thermostats Note: A closed switch between R and W will...
  • Page 4 We warrant products manufactured by Hydrolevel Company to be free from defects Hydrolevel Company be liable for any other loss or damage, whether direct, indirect, in material and workmanship for a period of two years from the date of manufac- incidental or consequential.

This manual is also suitable for:

Hydrozone 600146-6001

Table of Contents