Zoeller 71 HD Series Owner's Manual
Zoeller 71 HD Series Owner's Manual

Zoeller 71 HD Series Owner's Manual

Submersible grinder units

Advertisement

Quick Links

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
NOTICE TO INSTALLER:
Instructions must remain with
installation.
Congratulations on the purchase of the Zoeller 71 Series submersible
grinder pump. Zoeller Grinder Pumps are designed for grinding and pumping
sanitary sewage from submersible lift stations. The pump is intended to grind
and pump reasonable quantities of disposable diapers, sanitary napkins, paper
towels, rubber materials, plastics, cigarette butts and other items normally
found in sanitary sewage applications. Since 1939, the name Zoeller has
represented the standard for submersible dewatering and sewage pumps.
The same high quality workmanship and easy maintenance design has
been incorporated into this line of heavy-duty submersible grinder pumps.
This Zoeller pump will provide years of trouble-free service when installed
according to the manufacturers' recommendations.

TABLE OF CONTENTS

Safety Instructions ........................................................................ 1
Limited Warranty ........................................................................... 2
Preinstallation Information..........................................................3
Electrical Data ............................................................................... 3
Typical Sewage Installation ......................................................4
Pump Wiring Instructions ........................................................ 5-6
Operation......................................................................................... 7
Maintenance .................................................................................. 7
Service Checklist .......................................................................... 8
OWNER'S INFORMATION
Model Number: _______________ Date Code: ______________
Serial Number: Pump 1_____________ Pump 2_____________
 Simplex  Panel P/N _____________________________
 Duplex  Rail System P/N ________________________
Job Name: ____________________________________________
Distributor: ____________________________________________
Sales Order Number: ____________________________________
Contractor: ____________________________________________
Date of Installation: _____________________________________
System Readings During Operation: Voltage_____ Amps______
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
Tel: (502) 778-2731 • 1 (800) 928-PUMP
OWNER'S MANUAL
71 HD SERIES SUBMERSIBLE GRINDER UNITS
© Copyright 2023 Zoeller
This manual incorporates the installation, operation, maintenance, and
service instructions into one document to aid in the ownership of a Zoeller
submersible wastewater product. Please read and review this manual before
installing the product. Follow the steps and procedures listed on ZM1074 for
a proper start-up. Many items contained within, when followed correctly,
will not only ensure a long and problem-free life for the pump, but also save
time and money during installation. Reference ZM1788 for repair manual on
71 Series Grinder Pumps. Should further assistance be necessary please
call our Product Support Department at 1-800-928-PUMP (7867).

SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION
AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH
THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the
manual, look for one of the following signal words
and be alert to the potential for personal injury or
property damage.
Warns of hazards that WILL cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
INDICATES SPECIAL INSTRUCTIONS WHICH ARE
VERY IMPORTANT AND MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS
PRIOR TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
SECTION: Z4.20.140
ZM1789
0123
Supersedes
1222
Visit our website:
zoellerengineered.com
F A M I LY O W N E D
AMERICAN
PROUD

Advertisement

Table of Contents
loading

Summary of Contents for Zoeller 71 HD Series

  • Page 1: Table Of Contents

    This manual incorporates the installation, operation, maintenance, and grinder pump. Zoeller Grinder Pumps are designed for grinding and pumping service instructions into one document to aid in the ownership of a Zoeller sanitary sewage from submersible lift stations. The pump is intended to grind submersible wastewater product.
  • Page 2: Limited Warranty

    16,000 7111 High Flow 20,000 7112 High Flow 24,000 *Zoeller Company does not recommend a simplex station on anything over two homes in order to maintain continuous service during unusual conditions. © Copyright 2023 Zoeller Co. All rights reserved. ®...
  • Page 3: Preinstallation Information

    3450 18.0 13.0 0.62 G7111 3450 BA7111* 3450 J7112 7-1/2 3450 25.3 18.4 0.44 F7112 7-1/2 3450 22.0 16.0 0.62 G7112 7-1/2 3450 11.0 BA7112* 7-1/2 3450 *Obsolete as of 1/2023 © Copyright 2023 Zoeller Co. All rights reserved. ®...
  • Page 4: Typical Sewage Installation

    (14) Install ring and cable for lifting pump from pit. (7) Vent gases and odors to the atmosphere through vent pipe per (15) Basin must be clean and free of debris after installation and Local and State codes. before operation. © Copyright 2023 Zoeller Co. All rights reserved. ®...
  • Page 5: Pump Wiring Instructions

    This resistance reading should indicate an open circuit. If VOM reading returns a reading other than open, then a problem exists with the sensor circuit wiring or cordage. If resistance readings show a problem with either test, then pump should be repaired by a Zoeller Authorized Service Station. CONTROL PANELS These pumps are nonautomatic and they require a control panel.
  • Page 6 All single phase models require start capacitor, run capacitor and relay in the circuit to start and operate properly. These components can be purchased separately or prewired in a Zoeller control panel. For components purchased separately use the diagram for installation and hookup.
  • Page 7: Operation

    OPERATION GENERAL Once the above has been verified proceed with the following checks: Zoeller pumps are lubricated and tested at the factory prior to shipment and require • Pump power cables properly connected to panel. minimum pre-start-up maintenance. • Float cables properly connected to panel.
  • Page 8: Service Checklist

    - Abrasive material & chemical, deteriorated impeller and pump housing If the above check list does not uncover the problem, consult the factory. Do not attempt to service or otherwise disassemble pump. © Copyright 2023 Zoeller Co. All rights reserved. ®...

This manual is also suitable for:

711071117112