Zoeller 840 Owner's Manual

Zoeller 840 Owner's Manual

Submersible grinder units
Hide thumbs Also See for 840:

Advertisement

NOTICE TO INSTALLER: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
MODELS 840, 841 & 842 SUBMERSIBLE GRINDER UNITS
Congratulations on the purchase of a Zoeller
grinder pump. Since 1939, the name Zoeller
the standard for submersible dewatering and sewage pumps.
The same high quality workmanship and easy maintenance
design has been incorporated into this line of heavy-duty
submersible grinder pumps. This Zoeller
years of trouble-free service when installed according to the
manufacturer's recommendations.
This manual incorporates the installation, operation,
maintenance, and service instructions into one document to

Table of Contents

Safety Instructions ....................................................................... 1
Limited Warranty and Application .............................................. 2
Preinstallation Checklist .............................................................. 3
General Information ..................................................................... 4
Pump Wiring Instructions ............................................................ 5
Typical Indoor Prepackaged System .......................................... 6
Indoor Prepackaged Installation Instructions ........................... 7
Typical Outdoor Prepackaged System ....................................... 8
Operation ..................................................................................... 10
Cutter Maintenance .................................................................... 11
Service Checklist ........................................................................ 12
Owner's Information
Model Number: ______________ Date Code: _______________
 Simplex
 Packaged System
Job Name: ____________________________________________
Distributor: ____________________________________________
Date of Purchase: _________ Zoeller S/O No.: ______________
Contractor: ____________________________________________
Date of Installation: ____________________________________
System Readings During Start-up: Voltage _____ Amps _____
MAIL TO: P .O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
OWNER'S MANUAL
submersible
®
has represented
®
pump will provide
®
Duplex
Field Assembled System
© Copyright 2018 Zoeller
aid in the ownership of a Zoeller
product. Please read and review this manual before installing
the product. Follow the steps in this manual for a proper start-
up. Many items contained within, when followed correctly,
will not only ensure a long and problem-free life for the pump,
but also save time and money during installation. Reference
FM1308 for model 840, FM2445 for model 842 and FM2180
for model 841 replacement parts. Should further assistance
be necessary please call our Technical Service Department at
1-800-928-PUMP (7867).

Safety Instructions

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION
AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH
THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the
manual, look for one of the following signal words
and be alert to the potential for personal injury or
property damage.
Warns of hazards that WILL cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury
CAUTION
or property damage.
INDICATES SPECIAL INSTRUCTIONS WHICH ARE
VERY IMPORTANT AND MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS
PRIOR TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
PUMPS WITH THE "UL" MARK AND PUMPS WITH THE "US"
MARK ARE TESTED TO UL STANDARD UL778. CSA CERTIFIED
PUMPS ARE CERTIFIED TO CSA STANDARD C22.2 NO. 108.
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
1
FM2168
0318
Supersedes
0615
Visit our web site:
zoellerpumps.com
submersible wastewater
®

Advertisement

Table of Contents
loading

Summary of Contents for Zoeller 840

  • Page 1: Table Of Contents

    Reference ® years of trouble-free service when installed according to the FM1308 for model 840, FM2445 for model 842 and FM2180 manufacturer’s recommendations. for model 841 replacement parts. Should further assistance This manual incorporates the installation, operation, be necessary please call our Technical Service Department at 1-800-928-PUMP (7867).
  • Page 2: Limited Warranty And Application

    For applications where a lift station would handle between 15 and 60 homes, consider the 71 Series grinder pump, which is available through Zoeller Engineered Products. For applications where a lift station would handle more than 60 homes, a solids handling type pump should be considered.
  • Page 3: Preinstallation Checklist

    1. Make sure pump connection contains a ground terminal. The 1. Make sure the power source is capable of handling the electrical power cord on all Zoeller Grinder Pumps contains a green conductor requirements of the grinder pump, as indicated on the nameplate.
  • Page 4: General Information

    4. A properly sized disconnect switch, supplied by others, shall be installed on the service side of the pump and control panel. 4. The 840, 841 and 842 Grinder Pumps are dual seal and have seal leak probes. Single phase units have an internal thermal overload.
  • Page 5: Pump Wiring Instructions

    OVERLOAD RUN CAPACITOR START RELAY L1 L2 AUXILIARY WINDING RUN CAPACITOR START CAPACITOR MAIN WINDING SK2399 SK2400 THREE PHASE FIGURE 4. MODELS 840, 841 & 842 LEAD IDENTIFICATION WIRING DIAGRAM 208V/230/460V SENSOR POWER 18-4 3ø POWER CORD CORD 14-4 18-5...
  • Page 6: Typical Indoor Prepackaged System

    60” 24” NOMINAL SK1695 All installations must comply with all applicable electrical and plumbing codes, including but not limited to the National Electrical Code, local, regional and/or state plumbing codes, etc. © Copyright 2018 Zoeller Co. All rights reserved. ®...
  • Page 7: Indoor Prepackaged Installation Instructions

    Connect the float switch and pump cords. 3. Remove the unit from the packing. Indoor prepackaged systems are preassembled at the Zoeller Company and require a minimum 10. Clean any debris out of the basin. Fill the basin with water and of field assembly work.
  • Page 8: Typical Outdoor Prepackaged System

    FIBERGLASS AFD SK3110 24" MIN. All installations must comply with all applicable electrical and plumbing codes, including but not limited to the National Electrical Code, local, regional and/or state plumbing codes, etc. © Copyright 2018 Zoeller Co. All rights reserved. ®...
  • Page 9: Outdoor Prepackaged Installation Instructions

    2. Remove the unit from packing. Prepackaged outdoor systems on more specific requirements. are preassembled at the Zoeller Company and require a minimum 8. PVC or HDPE discharge piping is connected to the 2” threaded of field assembly work. Float switches are set and tethered for fitting located in the basin sidewall.
  • Page 10: Operation

    Operation GENERAL Zoeller pumps are lubricated and tested at the factory prior to • Pump power cables and control floats properly installed and shipment and require minimum pre-start-up maintenance. voltage verified. • Conduit connections to panel and junction box are properly Maximum operating temperature of pump liquid for grinder pumps sealed.
  • Page 11: Cutter Maintenance

    Add oil if required. Use insulating oil supplied by the factory. (Model 840 components shown) Grind the Star Cutter and Disc seen here to a 32 microfinish. Surfaces must be flat to within 0.001" T.I.R. Gap must be between 0.004"...
  • Page 12: Service Checklist

    If the above checklist does not uncover the problem, consult the factory. Do not attempt to service or otherwise disassemble pump. Service must be performed by Zoeller Authorized Service Stations. Go to www.zoellerpumps.com/servicestations to find the Authorized Service Station in your area.

Table of Contents