Hilti NCV 10-22 Manual page 13

Hide thumbs Also See for NCV 10-22:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
3. Hook the strain relief to the waist belt.
6.3
Activating power outlet
▶ Activate the operating switch to establish the electricity supply to the power outlet.
▶ The green LED indicates that the power outlet is activated.
▶ The orange LED indicates a low battery charge.
6.4
Operating internal vibrator
▶ To operate the internal vibrator correctly, follow the directions in its operating instructions.
6.5
Deactivating power outlet
When you stop working with the internal vibrator, always also deactivate the power outlet of the NCV 10­22.
▶ Deactivate the operating switch to switch off the electricity supply to the power outlet.
▶ The LEDs go out.
The power outlet of the NCV 10­22 is deactivated automatically after 30 minutes of non-use.
7
Care and maintenance
WARNING
Risk of injury with battery inserted !
▶ Always remove the battery before carrying out care and maintenance tasks!
Care of the product
Carefully remove stubborn dirt.
Carefully clean the air vents, if present, with a dry, soft brush.
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Use a dry, clean cloth to clean the contacts of the product.
Care of the Li­ion batteries
Never use a battery with clogged air vents. Clean the air vents carefully using a dry, soft brush.
Avoid unnecessary exposure of the battery to dust and dirt. Never expose the battery to high levels of
moisture (e.g. by being dipped in water or left in the rain).
If a battery has been soaked by moisture, treat it as a damaged battery. Isolate it in a non-flammable
container and consult Hilti Service.
Keep the battery free of extraneous oil and grease. Do not permit dust or dirt to accumulate unnecessarily
on the battery. Clean the battery with a dry, soft brush or a clean, dry cloth. Do not use cleaning agents
containing silicone as these can attack the plastic parts.
Do not touch the contacts of the battery and do not remove the factory-applied grease from the contacts.
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Maintenance
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
Do not use the product if signs of damage are found or if parts malfunction. Immediately have the product
repaired by Hilti Service.
After cleaning and maintenance, install all guards and protective devices and check that they are in full
working order.
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare
parts, consumables and accessories approved by Hilti for use with your product can be found at your
Hilti Store or online at: www.hilti.group
*2370142*
9
9
2370142
English
7

Advertisement

Table of Contents
loading

Table of Contents