Siemens SITRANS LG270 Operating Instructions Manual page 16

Guided wave radar
Table of Contents

Advertisement

Mounting in the vessel
insulation
16
1
2
Fig. 6: Fasten the probe
1
Coax probe
2
Retaining sleeve
Instruments for a temperature range up to +250 °C (482 °F) have a
spacer between process fitting and electronics housing. This spacer
is used to thermally decouple the electronics from the high process
temperatures.
Information:
The spacer may be incorporated in the vessel insulation up to max.
50 mm (2 in). Only then is a reliable temperature decoupling guaran-
teed.
Fig. 7: Mounting the instrument on insulated vessels.
1
Temperature insulation
2
Ambient temperature on the housing
SITRANS LG270 - Operating Instructions