Mounting Location

The 5400 series converter is designed for indoor use only! Do not mount in
engine compartment or other harsh environments; avoid areas where high levels of
dust, dirt, or moisture may occur.
The Parallax 5400 series power converter is of solid state design and does not
contain relays or mechanical devices that produce arcs or sparks, but in the unlikely
event that an electronic component would fail, Parallax does not recommend mounting
the power converter in battery compartments or in areas where flammable materials
are stored.

Wire Routing

In order to minimize radio and T.V. interference, avoid routing supply and output
wiring across fan intake or adjacent to ventilation slots of the converter.

Mounting Position

The 5400 series converters require horizontal mounting. Do not mount vertically or
upside down. Allow adequate ventilation for fan intake and exhaust. Mount the 5400
series converter utilizing the mounting holes in the front and rear flanges and using
fasteners appropriate for the mounting surface.

Input Supply Requirements

Connect to a 120VAC 60HZ 3-wire grounded supply with no larger than 20 ampere
circuit protection.

Mounting Clearances

Provide a minimum of three inches on all sides of the converter. Do not mount in
zero clearance compartments; overheating and thermal shut down will result.
011-5400-100 Rev. A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PARALLAX POWER SUPPLY PARAMODE 5400 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Connecticut Electric PARALLAX POWER SUPPLY PARAMODE 5400 Series

  • Page 1 Mounting Location The 5400 series converter is designed for indoor use only! Do not mount in engine compartment or other harsh environments; avoid areas where high levels of dust, dirt, or moisture may occur. The Parallax 5400 series power converter is of solid state design and does not contain relays or mechanical devices that produce arcs or sparks, but in the unlikely event that an electronic component would fail, Parallax does not recommend mounting the power converter in battery compartments or in areas where flammable materials...
  • Page 2 battery. In hot climates the output voltage of the converter will automatically be 5400 Series lowered, which will aid in reducing excessive out-gassing of the battery caused by the battery requiring a lower “float” voltage. Owner’s Manual Also with the addition of the TempAssure module and sensor cable, the 5400 series converter will automatically start out in a “boost”...

Table of Contents