ATE RTE-140 Instruction And Operation Manual

Refrigerated bath/circulator with analog/digital controller

Advertisement

Quick Links

®
Advanced Test Equipment Rentals
www.atecorp.com 800-404-ATEC (2832)
R R R R R TE-140 Refrig
TE-140 Refrig
TE-140 Refrig
TE-140 Refrig
TE-140 Refrigerated
Bath/Cir
Bath/Cir
Bath/Cir
Bath/Cir
Bath/Circulator
With Analog/Digital Contr
With Analog/Digital Contr
With Analog/Digital Contr
With Analog/Digital Contr
With Analog/Digital Controller
Instruction and Operation Man
Instruction and Operation Manual
Instruction and Operation Man
Instruction and Operation Man
Instruction and Operation Man
erated
erated
erated
erated
culator
culator
culator
culator
oller
oller
oller
oller
Thermo NESLAB Manual P/N 000022
Rev. 11/17/00
ual
ual
ual
ual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTE-140 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATE RTE-140

  • Page 1 ® Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R R R R R TE-140 Refrig TE-140 Refrig TE-140 Refrig erated erated TE-140 Refrig TE-140 Refrigerated erated erated Bath/Cir Bath/Cir culator culator Bath/Cir Bath/Cir Bath/Circulator culator culator With Analog/Digital Contr With Analog/Digital Contr oller oller With Analog/Digital Contr...
  • Page 2: Table Of Contents

    R R R R R TE-140 Refrig TE-140 Refrig TE-140 Refrigerated Bath/Cir TE-140 Refrig erated Bath/Cir erated Bath/Cir erated Bath/Circulator culator culator culator TE-140 Refrig erated Bath/Cir culator Instruction and Operation Man Instruction and Operation Man Instruction and Operation Manual Instruction and Operation Man Instruction and Operation Man T T T T T ab...
  • Page 3: Preface

    Preface Preface Preface Preface Preface Compliance Compliance Compliance Compliance Compliance Products tested and found to be in compliance with the requirements defined in the EMC standards defined by 89/336/EEC as well as Low Voltage Directive (LVD) 73/23/EEC can be identified by the CE label on the rear of the unit. The testing has demonstrated compliance with the following directives: LVD, 73/23/EEC Complies with UL 3101-1:93...
  • Page 4: Warnings

    Section I Saf Section I Saf Section I Saf Section I Saf Section I Safety Warnings Warnings Warnings Warnings Warnings Make sure you read and understand all instructions and safety precautions listed in this manual before installing or operating your unit. If you have any questions concerning the operation of your unit or the information in this manual, contact our Sales Department.
  • Page 5: Description

    Description Description Description Description The RTE-140 Refrigerated Bath/Circulators are designed to provide tempera- ture control for applications requiring a fluid work area or pumping to an external system. Units consist of a non-CFC air-cooled refrigeration system, circulation pump, seamless stainless steel bath, work area cover, and a temperature controller.
  • Page 6: Site

    Section III Installation Section III Installation Section III Installation Section III Installation Section III Installation Site Site Site Site Site The indentations on the sides of the unit are designed to function as handles. Lift the unit by the handles and locate it on a sturdy table or bench top. Ambient temperatures should be inside the range of +50°F to +104°F (+10°C to +40°C).
  • Page 7: Plumbing Requirements

    Plumbing Requirements Plumbing Requirements Plumbing Requirements Plumbing Requirements Plumbing Requirements Ensur Ensur Ensure the unit is off before connecting tubing to the unit. Ensur Ensur e the unit is off before connecting tubing to the unit. e the unit is off before connecting tubing to the unit. e the unit is off before connecting tubing to the unit.
  • Page 8 Circulating to an open container Circulating to an open container Circulating to an open container Circulating to an open container Circulating to an open container Levelling Device Outlet Inlet Bath (Rear View) Open Container A stainless steel leveling device is available to aid circulation to an open vessel.
  • Page 9: Fluids

    Drain Drain Drain Drain Drain Ensure the temperature of the bath fluid is safe before draining the unit. Ensure the temperature of the bath fluid is safe before draining the unit. Ensure the temperature of the bath fluid is safe before draining the unit. Ensure the temperature of the bath fluid is safe before draining the unit.
  • Page 10: Controllers

    Section IV Contr Section IV Contr Section IV Contr Section IV Contr Section IV Controller oller oller oller ollers s s s s Controllers Controllers Controllers Controllers Controllers Two standard temperature controllers are available with the unit: Analog and Digital. This section explains the installation and operation of the controllers. Start Up Start Up Start Up...
  • Page 11: Shut Down

    Digital Temperature Adjustment Digital Temperature Adjustment Digital Temperature Adjustment Digital Temperature Adjustment Digital Temperature Adjustment To display the temperature setpoint, press the DISPLAY switch. To adjust the setpoint, press and hold the DISPLAY switch and turn the COARSE and FINE dials until the temperature setpoint is indicated on the LED display. NOTE: NOTE: NOTE: Inadvertent movement of the COARSE and FINE dials, regardless of...
  • Page 12: High Temperature/Low Liquid Level Safety

    High Temperature/ High Temperature/ High Temperature/ High Temperature/ High Temperature/ Low Liquid Low Liquid Low Liquid Low Liquid Low Liquid Level Safety Level Safety Level Safety Level Safety Level Safety To protect your application, the adjustable High Temperature/Low Liquid Level Safety (HIGH TEMP/LOW LEVEL) ensures the heater will not exceed temperatures which can cause serious damage to your unit.
  • Page 13: 15-Pin Accessory Connector

    15-Pin Accessory 15-Pin Accessory 15-Pin Accessory 15-Pin Accessory 15-Pin Accessory Connector Connector Connector Connector Connector Digital units are equipped with a 15 pin D-subminiature female receptacle on the right side of the power box. An ENABLE/DISABLE switch is located just below the receptacle.
  • Page 14: Maintenance

    Section Section V Maintenance Section V Maintenance V Maintenance V Maintenance Section Section V Maintenance To avoid electrical shock, disconnect the mains cord prior to remov- To avoid electrical shock, disconnect the mains cord prior to remov- To avoid electrical shock, disconnect the mains cord prior to remov- To avoid electrical shock, disconnect the mains cord prior to remov- To avoid electrical shock, disconnect the mains cord prior to remov- ing any access panels or covers.
  • Page 15: Reservoir Cleaning

    Reservoir Cleaning Reservoir Cleaning Reservoir Cleaning Reservoir Cleaning Reservoir Cleaning Routine cleaning can be achieved by simply sponging down the seamless stainless steel tank with tap water. (Dish washing detergent may be used but the tank must be thoroughly rinsed.) To gain access to the entire reservoir the pump box and reservoir cover should be removed.
  • Page 16: Checklist

    Section Section Section Section Section VI VI VI VI VI T T T T T r r r r r oub oubleshooting leshooting leshooting leshooting leshooting Checklist Checklist Checklist Checklist Checklist Unit will not start Unit will not start Unit will not start Unit will not start Unit will not start Make sure the voltage of the power source meets the specified voltage,...
  • Page 17 A A A A A PPENDIX PPENDIX PPENDIX PPENDIX PPENDIX NEScom SOFTW NEScom SOFTW NEScom SOFTWARE NEScom SOFTW NEScom SOFTW The Thermo NESLAB Communications Software is a user friendly software that allows you to automate your temperature control process. The software includes a 3½"...
  • Page 18: Warranty

    WARRANTY Thermo NESLAB Instruments, Inc. warrants for 12 months from date of shipment any Thermo NESLAB unit according to the following terms. Any part of the unit manufactured or supplied by Thermo NESLAB and found in the reasonable judgment of Thermo NESLAB to be defective in material or workmanship will be repaired at an authorized Thermo NESLAB Repair Depot without charge for parts or labor.