Page - Training Chapter 5 Page - Maintenance 13-16 - Servicing and Maintenance Activities 17-18 - Troubleshooting 18-19 Chapter 6 Page - Pictures 20-21 FIREBULL® is a registered trademark of Enforcer One, LLC Enforcer One, LLC Page 2 Copyright 2020...
Page 3
Enforcer One, LLC , this warranty shall be void and Enforcer One, LLC shall have no obligation to repair or replace the failed product. Fluorine Free Foam products will void the The use of any foam product other than FIREBULL ®...
Page 4
MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. No person or entity is authorized to bind Enforcer One, LLC to any other warranty obligation or liability to distributer, purchaser or any third party for any loss of profits, economic loss, indirect, incidental, punitive, special or consequential damages whatsoever and howsoever caused.
Page 5
Enforcer One, LLC product(s) are in-use. DO NOT attempt to use this or any Enforcer One, LLC line of product(s) in the event that the fire represents a situation that is beyond the capabilities of the Operator and/or the Equipment.
Premix Tank through a regulator and hose assembly. Discharge hose include one 300’ section of 1” Booster Hose on a hose reel with pistol grip style nozzle. Enforcer 200 also includes one 50’ section of 1.5” lay flat hose with pistol grip style nozzle. The Enforcer 200 can discharge both hoses simultaneously.
FIREBULL® Fluorine Free Foam Products 3-2. a. Enforcer 3 Backpack should only be used with FIREBULL® Fluorine Free Foam products mixed at a 1%, 3% or 6% solution for low, medium and high expansion. b. It is recommended that a FIREBULL® Freeze Protected Fluorine Free Foam Product be used when positioning the unit outside during extended subfreezing weather.
Disconnect fill tower Cap check liquid level. b. Fill up the Premix Tank if low. _______ 4. Check the tire condition. Note any other Problems: FIREBULL® is a registered trademark of Enforcer One, LLC Enforcer One, LLC Page 8 Copyright 2020...
3. Close the Air Cylinder Valve. 4. Open Nozzle valve to depressurize the hose line. 5. Open the Depressurizing Valve to depressurize the Premix Tank. 6. Secure discharge hose. FIREBULL® is a registered trademark of Enforcer One, LLC Enforcer One, LLC Page 9 Copyright 2020...
Chapter 4 Training Training Program 4-1. a. Training on the Enforcer 200 should be conducted or reviewed annually for all operators b. Maintenance personnel should complete initial training and refresher training as required c. Trainers should be thoroughly familiar with the system, fire behavior, hazard identification, and basic firefighting techniques d.
Technical Assistance 5-2. Maintenance personnel should contact Enforcer One whenever any problem arises that cannot be solved using the information in this manual or when unusual situations are encountered or expected. FIREBULL® is a registered trademark of Enforcer One, LLC...
Page 12
Enforcer 200 Maintenance Log Preventative Maintenance Checks and Services (PMCS) Refer to Chapter 5 – Maintenance for specific activities Maintenance Date Performed By Notes/Comments Activity Completed FIREBULL® is a registered trademark of Enforcer One, LLC Enforcer One, LLC Page 12 Copyright 2020...
Page 13
Visual Inspection Air Regulator Every 2 years Inspection Air Cylinder Every 5 Years Hydrostatic Test Premix Cylinder Every 5 Years and Discharge Hose Hydrostatic Test FIREBULL® is a registered trademark of Enforcer One, LLC Enforcer One, LLC Page 13 Copyright 2020...
Page 14
Unscheduled Maintenance Maintenance Activity Date Performed Comments/Notes Completed FIREBULL® is a registered trademark of Enforcer One, LLC Enforcer One, LLC Page 14 Copyright 2020...
Page 15
Important Note: The Premix Tank Manifold should be tightened by hand. Do not use any wrenches or Teflon tape or thread sealant on any of the Premix tank fittings. FIREBULL® is a registered trademark of Enforcer One, LLC Enforcer One, LLC Page 15...
32 degrees Fahrenheit. FIREBULL® should be used in the concentrate form in cold or freezing temperature conditions. FIREBULL® Fluorine Free Foam is a solution made by Enforcer One, LLC. The Pre-Mix solution is already mixed, this means Water and Foam, no need for mixing onsite. Maintenance personal should open the Pre-Mix bucket and fill the Enforcer unit full of the Pre-Mix solution.
Page 17
Storage and Protection 5-8. a. The Enforcer 200 does not have any special storage requirements if stored inside. b. A protective cover is recommended and should be used if the equipment is stored outside as this will reduce sun damage to hoses and gauges.
Need help?
Do you have a question about the FIREBULL 200 and is the answer not in the manual?
Questions and answers