Summary of Contents for Tyco Security Products DSC Neo Power Series
Page 1
TL880LT Dual Path Controller TL880LE Dual Path Controller WARNING: This manual contains information on limitations regarding product use and function and inform- ation on the limitations as to liability of the manufacturer. The entire manual should be carefully read. - 1 -...
Introduction Features Communicator ratings Communicator compatibility UL Installation Requirements Installation Tools and supplies required Step 1: Enable module Step 2: Connect the TL880LT/TL880LE Step 3: Verify installer code to activate Alarm.com module Step 4: Perform dual-path test (module registration) Step 5: Allow module to auto-program Panel settings Troubleshooting Module status information...
Page 3
ARNING NSTALLER LEASE AREFULLY Note to installers The warnings on this page contain vital information. As the only individual in contact with system users, it is the installer’s responsibility to bring each item in this warning to the attention of all users of this system. System failures This system has been carefully designed to be as effective as possible.
Page 4
Security and insurance Regardless of its capabilities, an alarm system is not a substitute for property or life insurance. An alarm system also is not a substitute for property owners, renters, or other occupants to act prudently to prevent or minimize the harmful effects of an emergency situation. Smoke detectors Smoke detectors that are a part of this system may not properly alert occupants of a fire for a number of reasons, some of which follow.
Position cables so that accidents cannot occur. This equipment must be installed and used within an environment that provides the pollution degree max 2 and over-voltages category II NONHAZARDOUS LOCATIONS, indoor only. The equipment is designed to be installed, serviced and/or repaired by Skilled Persons only; (skilled person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons).
in a trouble condition. 2-way audio capable when used with audio module HSM2955(R) - Refer to HSM2955(R) manual. Communicator ratings Model TL880LT TL880LE Power supply ratings 11.3V - 12.5V DC Input Voltage (provided by compatible DSC NEO control panel) Current consumption Standby Current (Average Value) 150mA Alarm (Transmitting) Current (Peak Value)
Installation NSTALLATION Follow these guidelines during installation. Before affixing the communicator to a wall, verify the LTE signal level at the installation location. On a keypad, press and hold the 5 key for 2 seconds to view the LTE signal level. An installation location with a sustained signal level of two or more bars is recommended.
Installation Mounted in Alarm Controller Cabinet PCL-422 TX+ TX- +12V Controller Board +12V A Red wire on alarm controller PCLink2 Header B Antenna access ports C Ethernet cable D Quad cables (100' / 30m maximum) E Red wire on PCL-422 PCLink Header F LTE Controller Board power terminals.
Installation 2: Connect power The maximum cable length permitted for the power connection is 100ft/30m. Connect the GND terminal on the TL880LT/TL880LE to the GND terminal on the PCL-422 Connect the +12V terminal on the TL880LT/TL880LE to the +12V terminal on the PCL-422 3: Connect the PC-Link cable Note: To ensure correct orientation, refer to items A and D in the wiring diagrams for the proper position of the red wire on the PC-link cable.
Installation press and hold [4] for two seconds. A Dual-Path test can also be completed through the Interactive Services menu. To perform the Dual-Path test, press [*][6] followed by the master code and [04]. The panel indicates when the test has completed by activating the siren output on medium volume for 2 seconds followed by full volume for 2 seconds.
Page 11
Installation Section Option Description 310 [007] Partition 7 account number 310 [008] Partition 8 account number 311 [001] Partition 1 Call Direction - Alarm/Restore 311 [002] Partition 1 Call Direction - Tamper/Restore 311 [003] Partition 1 Call Direction - Opening/Closing 312 [001] Partition 2 Call Direction - Alarm/Restore 312 [002]...
Page 12
Installation Section Option Value Description Master code is not changeable and must be OFF to ensure the module communicates the correct master code. Daylights saving time must be disabled to ensure panel time is accurate. Set according to Enables Duress Code changes from dealer's Alarm.com Alarm.com.
Troubleshooting ROUBLESHOOTING Module status information Module status information for verifying and troubleshooting the module connection status or errors can be found through the Interactive Services menus. To access these, press [*][8][Installer Code][851]. See the fol- lowing table for potential module states. Status Description Idle...
Page 14
Troubleshooting Status LEDs L1 L2 L3 L4 L5 LED functions Function General & Cellular Error LED. Flashes 1 to 8 times in an 8-second interval to indicate specific error. See section “LED L1 (red)” for errors and common fixes. Broadband Errors & Panel Communication. Flashes 2 to 8 times in an 8-second interval to indicate a specific error on the broadband path.
Page 15
Troubleshooting Number of Error and solution flashes The module is registered on the LTE network but cannot connect with Alarm.com. Power down the module, wait one minute, restore power and perform a communications test. Verify signal strength and try a different location for the module/antenna. If the problem persists, contact Alarm.com Technical Support.
Troubleshooting LED L5 (yellow) LED L5 indicates Z-Wave state and errors. See the table below for more information. Number of flashes Device status or error Successfully added/removed node (last 60 seconds) Delete Mode Add node attempt failed (last 60 seconds) because device already in network Add Mode Replicate Mode Learn Mode Error (lasts 60 seconds)
Troubleshooting the radio has 3 out of 5 bars or 13/31 and is connected to the network. Radio: 123__ 13 Connected Guidelines for optimal wireless signal strength: Install the module above ground level, as high up as possible within the structure. Install the module near or adjacent to an exterior-facing wall of the structure.
Interactive Service Menu NTERACTIVE ERVICE Interactive menus The “Interactive Services” menu can be used to access information about the TL880LT/TL880LE module, install or remove Z-Wave devices and configure or troubleshoot other interactive features. The menu will time out after 20 minutes. Refer to the following tables for the menu options. Installer programming Press [*][8][Installer Code][851] to enter Interactive Services menu.
Page 19
Interactive Service Menu Menu Description --SN See Installer Programming section ---SIM card See Installer Programming section ---Version See Installer Programming section ---Advanced - Network See Installer Programming section --Z-Wave Setup See Installer Programming section ---Number of Z-Wave Devices See Installer Programming section ---Add Z-Wave Device See Installer Programming section ---Remove Z-Wave Device...
until a valid purchase order is received from the Customer and a Limited Warranty Return Merchandise Authorisation number (RMA) is issued by DSC's Customer Service. Digital Security Controls warrants the original purchaser that for a Digital Security Controls’s liability for failure to repair the product period of twelve months from the date of purchase, the product shall be under this warranty after a reasonable number of attempts will be lim- free of defects in materials and workmanship under normal use.
Page 21
Software Product Transfer - You may transfer all of Your rights Software and any related Hardware) and Digital Security Controls, a division of Tyco Safety Products Canada Ltd. (“DSC”), the man- under this EULA only as part of a permanent sale or transfer of the ufacturer of the integrated security systems and the developer of the HARDWARE, provided You retain no copies, You transfer all of the software and any related products or components (“HARDWARE”)
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A - Connect the equipment into an outlet on a circuit different from that to PARTICULAR PURPOSE) AND OF ALL OTHER OBLIGATIONS which the receiver is connected. OR LIABILITIES ON THE PART OF DSC. DSC MAKES NO - Consult the dealer or experienced radio/television technician for help.
Page 23
HS2128/HS2064/HS2032/HS2016. The TL880LE can be used in com- mercial burglary applications up to Security Level IV. For ULC Listed installations refer also to ULC Installation Guide P/N 29002157. Notes for using Private, Corporate and High Speed Data Networks when using TL880LE: Network access and domain access policies shall be set to restrict unauthorized network access, and "spoofing"...
Need help?
Do you have a question about the DSC Neo Power Series and is the answer not in the manual?
Questions and answers