5
Plug the VTech Wiring Harness into the Controller module and press the connector firmly to ensure it snaps into
place. Restore power to the PTAC/PTHP.
6
With the unit connected to power but in OFF mode, update the Auxiliary Control menu to enable "Wired
Thermostat" functionality:
1. Press the red Aux Set button.
2. Using the face controls, press Mode button until the first digit in the display shows MODE 6 (Remote
Thermostat).
3. Using the face controls, press the Up arrow to turn this option ON, then press again to select 6A (Auto
changeover thermostat).
4. Press the red Aux Set button again to save the setting and exit the configuration mode.
7
Now that the VTech Controller is wired to the Amana unit and it is configured to be controlled by a wired
thermostat, install the batteries into the thermostat. The LED on the controller will change from alternating Green/
Red, to solid green to indicate it has established communication.

IMPORTANT NOTE

The W960 thermostat comes preregistered to the controller.
Be sure not to mix the units when removing them from the
packaging. Additionally, avoid pressing the pairing button on
the controller as this can delete the registration requiring you
to re-pair the thermostat and controller.