WARNING
Make certain power is OFF before starting installation
or attempting any maintenance.
WARNING
Risk of fire/electric shock. If not qualified, consult an
electrician.
WARNING
Risk of Electric Shock – Disconnect power at fuse or
circuit breaker before installing or servicing.
WARNING
Risk of Personal Injury – Fixture may become damaged
and/or unstable if not installed properly.
Do not mount luminaire within 6" of a
combustible surface.
Do not handle luminaire by the glass. Do not
touch LEDs.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the
attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the
housing to assure you have received the correct material.
SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and
ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under
installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited
ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not
expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photocontrol
or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow
blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following
recommendations.
WARNING
Risk of Burn – Disconnect power and allow fixture to
cool before servicing.
N
ote:
These instructions do not claim to cover all
details or variations in the equipment, procedure,
or process described, nor to provide directions
for meeting every possible contingency during
installation, operation or maintenance. When
additional information is desired to satisfy a
problem not covered sufficiently for user's purpose,
please contact your nearest representative.
This lighting fixture has been shipped complete
N
ote:
with one of several mounting options. Please follow
the installation instructions specific to the catalog
part that you ordered.
Care must be taken not to set lighting fixture down
N
ote:
on optical lenses or lift the fixture in the lens area.
N
ote:
Specifications and dimensions subject to change
without notice.
Brand Logo
reversed out of
black
INS #
INS #

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NFFLD L Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cooper Lighting Solutions NFFLD L Series

  • Page 1 Brand Logo reversed out of black IB506004EN INS # INS # Installation Instructions - NFFLD-L/UFLD-L Instructions d’installation - NFFLD-L/UFLD-L Instrucciones de instalación - NFFLD-L/UFLD-L WARNING WARNING Make certain power is OFF before starting installation Risk of Burn – Disconnect power and allow fixture to or attempting any maintenance.
  • Page 2: Installation

    Center Bolt Cover Plate Screws (3) Trunnion Bracket Center Bolt Set Screws (4) 2-5/16” (59mm) Cover Plate 3-13/16” (2) 9/16” (97mm) (15mm) Lock Nuts (4) 9-5/16” Pole 7/8” (23mm) (237mm) Figure 1. Figure 2. COOPER LIGHTING SOLUTIONS IB506004EN Installation instructions...
  • Page 3 Refer to wiring diagrams for power connection. (Figure 4.) Ground Green Figure 4. Yoke Connector Center Bolt Mounting Block Yoke Bracket 7/8” (23mm) (2) 9/16” (15mm) 2” (51mm) 3-13/16” (97mm) 19” (485mm) Figure 3. COOPER LIGHTING SOLUTIONS IB506004EN Installation instructions...
  • Page 4 Align visor on top of lens clips matching the (4) existing holes. (Figure 7 .) Use the existing (4) 10-24 Philips head screws to secure visor. To remove visor follow steps 1-3 in reverse order. Figure 5. Figure 7. COOPER LIGHTING SOLUTIONS IB506004EN Installation instructions...
  • Page 5 à proximité de surfaces bloquant la circulation de l'air dans un rayon de 15,2 cm (6 po). Les résultats seront meilleurs si le luminaire est installé et entretenu selon les recommandations suivantes. COOPER LIGHTING SOLUTIONS IB506004EN Instructions d’installation...
  • Page 6: Outillage Nécessaire

    Support du tourillon Boulon central recouvrement (4) vis 59 mm d'ajustement (2-5/16 po) Plaque de recouvrement 97 mm (2) 15 mm (3-13/16 (9/16 po) (4) écrous de blocage 237 mm Pôle 23 mm (7/8 po) (9-5/16 po) Figure 1 Figure 2 COOPER LIGHTING SOLUTIONS IB506004EN Instructions d’installation...
  • Page 7 Faites pivoter le luminaire jusqu'à la position désirée et serrez les boulons centraux à 102 Nm (75 pi-lb). Connecteur du berceau Boulon central Bloc de montage 23 mm Support du berceau (7/8 po) (2) 15 mm (9/16 po) 51 mm (2 po) 97 mm (3-13/16 po) 485 mm (19 po) Figure 3 COOPER LIGHTING SOLUTIONS IB506004EN Instructions d’installation...
  • Page 8 étapes 1 à 3 dans l'ordre inverse. Utilisez les (4) vis hexagonales 10-24 pour fixer fermement la visière. Pour retirer la visière, suivez les étapes 1 à 3 dans l'ordre inverse. Figure 5 Figure 7 COOPER LIGHTING SOLUTIONS IB506004EN Instructions d’installation...
  • Page 9 No instale la luminaria cerca de materiales combustibles, ni la ubique junto a menos de 6 pulgadas (15 cm) de superficies que bloqueen el flujo del aire. Se obtendrá un mejor resultado si se la instala y se le realiza el servicio de mantenimiento de acuerdo con las siguientes recomendaciones. COOPER LIGHTING SOLUTIONS IB506004EN Instrucciones de instalación...
  • Page 10: Instalación

    (4) tornillos 2-5/16” de sujeción (59 mm) Placa de la cubierta 3-13/16” (2) 9/16” (97 mm) (4) tuercas de (15 mm) sujeción Poste 9-5/16” 7/8” (23 mm) (237 mm) Figura 2. Figura 1. COOPER LIGHTING SOLUTIONS IB506004EN Instrucciones de instalación...
  • Page 11 Conexión a tierra Verde Figura 4. Conector de alimentación Perno central Bloque de montaje Soporte del reflector 7/8” (23 (2) 9/16” (15 mm) 2” (51 mm) 3-13/16” (97 mm) 19” (485 Figura 3. COOPER LIGHTING SOLUTIONS IB506004EN Instrucciones de instalación...
  • Page 12 (Figura 7 .) del 1-3 en orden inverso. Use los (4) tornillos de cabeza Phillips 10-24 para sujetar el visor. Para quitar el visor, siga los pasos 1-3 en orden inverso. Figura 5. Figura 7. COOPER LIGHTING SOLUTIONS IB506004EN Instrucciones de instalación...
  • Page 13 Veuillez consulter le site www.cooperlighting.com/legal pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com/legal para conocer nuestros términos y condiciones. Cooper Lighting Solutions 1121 Highway 74 South Cooper Lighting Solutions is a Peachtree City, GA 30269 registered trademark. P: 770-486-4800 All trademarks are property www.cooperlighting.com...

This manual is also suitable for:

Ufld l seriesNffldlc75tNffldlc75s

Table of Contents