Table of Contents

Advertisement

Quick Links

USER MANUAL
(Rev. BETA-ENG)
www.axeltechnology.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OXYGEN 3000 PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for AxelTech OXYGEN 3000 PLUS

  • Page 1 USER MANUAL (Rev. BETA-ENG) www.axeltechnology.com...
  • Page 2: Table Of Contents

    OXYGEN 3000 PLUS · User Manual · ENG SUMMARY SUMMARY SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA ................4 PREFACE..............................4 SAFETY WARNINGS ..........................5 CONSIGNES DE SÉCURITÉ IMPORTANTES ....................7 ISTRUZIONI IMPORTANTI PER LA SICUREZZA ..................9 WICHTIGE SICHERHEITSHINWEISE....................... 12 INSTRUCCIONES IMPORTANTES DE SEGURIDAD ................. 14 UNPACKING AND INSPECTION 1.
  • Page 3 OXYGEN 3000 PLUS · User Manual · ENG FADER SETTINGS ..........................44 VJ PRO MODE ............................ 45 4.1.2. INPUTS ..........................46 MIC (MIC-1 TO MIC-10) ........................46 ADV. SETTINGS ..........................49 MIC AUTOMIX ........................... 54 MONO / STEREO ..........................54 USB-1, USB-2 .............................
  • Page 4: Safety Warnings/Istruzioni Per La Sicurezza

    OXYGEN 3000 PLUS · User Manual · ENG SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA SAFETY WARNINGS CONSIGNES DE SÉCURITÉ IMPORTANTES ISTRUZIONI IMPORTANTI PER LA SICUREZZA WICHTIGE SICHERHEITSHINWEISE INSTRUCCIONES IMPORTANTES DE SEGURIDAD (Rel. 6.2.0.2) PREFACE For your safety and to prevent the warranty from being accidentally invalidated, please...
  • Page 5: Safety Warnings

    OXYGEN 3000 PLUS · User Manual · ENG SAFETY WARNINGS The installation and servicing instructions in this manual are for use by qualified personnel only. Read All Instructions. All safety and operating instructions must be read before operating the product. They also must be retained for future reference, as it contains many useful hints for determining the best combination of equipment settings for Yr particular application.
  • Page 6 OXYGEN 3000 PLUS · User Manual · ENG This symbol alerts you to the presence of dangerous voltage inside the closure – voltage that may be sufficient to constitute a risk of shock. Do not perform any servicing other than that contained in the operating instructions. Refer all servicing to qualified personnel.
  • Page 7: Consignes De Sécurité Importantes

    OXYGEN 3000 PLUS · User Manual · ENG CONSIGNES DE SÉCURITÉ IMPORTANTES Lire ces consignes. Conserver ces consignes. Observer tous les avertissements. Suivre toutes les consignes. Ne pas utiliser cet appareil à proximité de l’eau. Ne pas obstruer les ouvertures de ventilation. Installer en respectant les consignes du fabricant.
  • Page 8 OXYGEN 3000 PLUS · User Manual · ENG Ce symbole indique la présence d'une tension dangereuse dans l'appareil constituant un risque de choc électrique. Ce symbole indique que la documentation fournie avec l'appareil contient des instructions d'utilisation et d'entretien importantes.
  • Page 9: Istruzioni Importanti Per La Sicurezza

    OXYGEN 3000 PLUS · User Manual · ENG ISTRUZIONI IMPORTANTI PER LA SICUREZZA Leggere le presenti istruzioni. Conservare queste istruzioni. Osservare tutte le avvertenze. Seguire scrupolosamente tutte le istruzioni. Non usare questo apparecchio in prossimità di acqua. Non ostruire alcuna apertura per il raffreddamento. Installare l’apparecchio seguendo le istruzioni.
  • Page 10 OXYGEN 3000 PLUS · User Manual · ENG Il prodotto non và aperto per nessun motivo, non và modificato o manomesso. E' vietato tentare qualsiasi tipo di riparazione. E' obbligatorio leggere il manuale utente prima di utilizzare il prodotto. Il prodotto deve essere utilizzato da persone adulte. Tenere il prodotto fuori dalla portata dei bambini Il prodotto và...
  • Page 11 OXYGEN 3000 PLUS · User Manual · ENG Questo simbolo indica la presenza di alta tensione all'interno dell'apparecchio, che comporta rischi di scossa elettrica. Questo simbolo indica la presenza di istruzioni importanti per l'uso e la manutenzione nella documentazione in dotazione all'apparecchio.
  • Page 12: Wichtige Sicherheitshinweise

    OXYGEN 3000 PLUS · User Manual · ENG WICHTIGE SICHERHEITSHINWEISE Diese Hinweise LESEN. Diese Hinweise AUFHEBEN. Alle Warnhinweise BEACHTEN. Alle Anweisungen BEFOLGEN. Dieses Gerät NICHT in der Nähe von Wasser verwenden. KEINE Lüftungsöffnungen verdecken. Gemäß den Anweisungen des Herstellers einbauen.
  • Page 13 OXYGEN 3000 PLUS · User Manual · ENG Dieses Symbol zeigt an, dass gefährliche Spannungswerte, die ein Stromschlagrisiko darstellen, innerhalb dieses Geräts auftreten. Dieses Symbol zeigt an, dass das diesem Gerät beiliegende Handbuch wichtige Betriebs- und Wartungsanweisungen enthält. Vor Änderung der Netzspannung oder Sicherungswechsel Netzkabel trennen.
  • Page 14: Instrucciones Importantes De Seguridad

    OXYGEN 3000 PLUS · User Manual · ENG INSTRUCCIONES IMPORTANTES DE SEGURIDAD LEA estas instrucciones. CONSERVE estas instrucciones. PRESTE ATENCION a todas las advertencias. SIGA todas las instrucciones. NO utilice este aparato cerca del agua. NO obstruya ninguna de las aberturas de ventilación. Instálese según lo indicado en las instrucciones del fabricante.
  • Page 15 OXYGEN 3000 PLUS · User Manual · ENG Este símbolo indica que la unidad contiene niveles de voltaje peligrosos que representan un riesgo de choques eléctricos. Este símbolo indica que la literatura que acompaña a esta unidad contiene instrucciones importantes de funcionamiento y mantenimiento.
  • Page 16: Unpacking And Inspection

    OXYGEN 3000 PLUS · User Manual · ENG UNPACKING AND INSPECTION Your equipment was packed carefully at the factory in a container designed to protect the unit during shipment. Nevertheless, we recommend making a careful inspection of the shipping carton and the contents for any signs of physical damage.
  • Page 17: First Installation Recommendations

    OXYGEN 3000 PLUS · User Manual · ENG 1. F IRST NSTALLATION ECOMMENDATIONS POWER SUPPLY The apparatus is equipped with 2 standard XLR 4-pin connectors, namely primary and secondary, to facilitate a redundant power supply setup. It is worth noting that the second external power supply is OPTIONAL.
  • Page 18: Installation Note And First Step

    INSTALLATION NOTE AND FIRST STEP Best setup location OXYGEN 3000 PLUS should be installed avoiding direct sunlight, close proximity to radiators and air conditioning, dust, water, and chemicals. Choose a console location that permits a clear view of the indicators on the device and ensures sufficient heat dissipation of the device.
  • Page 19: First Connection

    OXYGEN 3000 PLUS · User Manual · ENG FIRST CONNECTION Connect a LAN cable to the OXYGEN LAN port on the back panel of the console. The device is automatically discoverable as a DHCP client in your network. Download the Oxygen Remoter setup file from the following URL: HTTPS://WWW.AXELTECHNOLOGY.COM/PUBLIC/OXYGENREMOTER/OXYGENREMOTERSETUP.EXE...
  • Page 20: Introduction

    OXYGEN 3000 PLUS · User Manual · ENG INTRODUCTION OXYGEN 3000 Plus x1 I/O Board OXYGEN 3000 Plus x2 I/O Board INTRODUCTION | FIRST CONNECTION...
  • Page 21 OXYGEN 3000 PLUS · User Manual · ENG  8, 12, or 16 faders broadcast digital console  Analog, digital, USB, AoIP, IP streaming inputs and outputs  Digital audio routing  AoIP interface Dante/AES67 (optional)  Audio Streaming Encoder/Decoder ...
  • Page 22: General Description

    OXYGEN 3000 PLUS · User Manual · ENG 2. GENERAL DESCRIPTION DIMENSIONS (8 P HYSICAL FADERS GENERAL DESCRIPTION | DIMENSIONS (8 Physical faders)
  • Page 23: Dimensions (12 Physical Faders)

    OXYGEN 3000 PLUS · User Manual · ENG DIMENSIONS (12 P HYSICAL FADERS GENERAL DESCRIPTION | DIMENSIONS (12 Physical faders)
  • Page 24: Dimensions (16 Physical Faders)

    OXYGEN 3000 PLUS · User Manual · ENG DIMENSIONS (16 P HYSICAL FADERS GENERAL DESCRIPTION | DIMENSIONS (16 Physical faders)
  • Page 25: Talkbox Dimensions

    OXYGEN 3000 PLUS · User Manual · ENG TALKBOX DIMENSIONS GENERAL DESCRIPTION | TALKBOX DIMENSIONS...
  • Page 26: Input Connections

    OXYGEN 3000 PLUS · User Manual · ENG INPUT CONNECTIONS 1. AOIP – LAN DANTE (OPTIONAL). 7. MIC 2, MIC 3 16 or 32 Stereo digital audio inputs over Ethernet. If the MIC input over the RJ45 connector includes 2 GPI and 1 DANTE board was not purchased with the device these GPO on each connector.
  • Page 27: Output Connections

    OXYGEN 3000 PLUS · User Manual · ENG OUTPUT CONNECTIONS 1. AOIP – LAN DANTE (OPTIONAL). 7. ANALOG OUTPUT (OUT 3, OUT 4) 16 or 32 Stereo digital audio outputs over Ethernet. If the 2 Stereo analog audio outputs over RJ45 connectors.
  • Page 28: Talkbox Connections

    OXYGEN 3000 PLUS · User Manual · ENG TALKBOX CONNECTIONS 1. Power Supply 6. Mic Light 12VDC 1A 2 PIN Screw Connector - (12VDC output). 2. ON AIR Light relay 7. Mic Input DC relay normally opens NO. XLR Female Connector.
  • Page 29: Surface

    OXYGEN 3000 PLUS · User Manual · ENG 3. SURFACE 1. CHANNEL CONTROLS The console offers 16 physical channel strips and an additional 8 virtual channels, affording complete control over the primary parameters of the channel. It features an integrated LCD screen for configuring the channel and adjusting the pre-fader audio levels.
  • Page 30: Channel Controls

    OXYGEN 3000 PLUS · User Manual · ENG 3.1. CHANNEL CONTROLS CHANNEL DISPLAY CHANNEL DISPLAY is used to display the status input source and the PRE-FADER audio level and the channel configuration. [MORE INFO ] GAIN knob for the adjustment of the input source level and for source switching between the primary source (CH-A) and the secondary source (CH-B) by pressing on the knob.
  • Page 31: Channel Display

    OXYGEN 3000 PLUS · User Manual · ENG 3.1.1. CHANNEL DISPLAY provides visual feedback on the status of the input source and the PRE-FADER audio level and the channel configuration. It is contained much useful information about the source configuration such as PRE-AMP, Gain, Pre-Fader Listen, signal type, Phantom, speaker cutting ��, on-air light, and much...
  • Page 32: F1 & F2

    OXYGEN 3000 PLUS · User Manual · ENG 3.1.3. F1 & F2 These are 2 configurable buttons that can be set in the physical channel to enable/disable many features such as (TalkBack, COMPRESSOR, DUCKING, and EQ).  In the CALL LINE sources such as "TELEPHONE, TELCO, OR BLUETOOTH" this button can be set as TELEPHONE for the incoming call signal, hook, and drop the call.
  • Page 33: Fader

    OXYGEN 3000 PLUS · User Manual · ENG When a channel switches from ON to OFF or standby status, the related LEDs switch from ON Colour to standby color. this function allows us to understand the channel and BUS's status.
  • Page 34: On/Start

    OXYGEN 3000 PLUS · User Manual · ENG 3.1.7. ON/START This button to enable/disable the channel (ON/OFF), the OFF status mutes the channel automatically, and the RGB LEDs under the buttons have three different statuses: 1) LED OFF - OFF status - the channel is MUTE.
  • Page 35 OXYGEN 3000 PLUS · User Manual · ENG Going to MENU / AUDIO / OUTPUTS / MONITOR / SETTINGS can change the PFL MODE between SINGLE PFL SUM PFL and with the SUM PFL you can listen to more than one PFL at the same time.
  • Page 36: Special Function Buttons

    OXYGEN 3000 PLUS · User Manual · ENG 3.2. SPECIAL FUNCTION BUTTONS 3.2.1. SNAPSHOTS Here we have 4 buttons and each button can be set to recall a specific CHANNELS snapshot that you've saved. Snapshot functionality allows you to save 10 presets for CHANNELS and can select which parameter to recall from the snapshot (EQ, COMPRESSOR, BUS ASSIGNMENT, FADER, PRE-MIC LEVEL, CHANNEL ON/OFF) and much more.
  • Page 37: Talkback

    OXYGEN 3000 PLUS · User Manual · ENG 3.2.3. TALKBACK The talkback system is a system used to facilitate communication between the mixing engineer or producer and the performers or other personnel in the studio. The mixing engineer or producer can use the talkback button on the mixing...
  • Page 38 OXYGEN 3000 PLUS · User Manual · ENG MODE: 1SEL, 1SEL+PFL, 2SEL or 2SEL+PFL PFL (pre-fader listen): This mode allows you to listen in speakers to the audio of the single channel before the intervention of the fader. 1SEL (one selection): This option allows you to listen in speakers to only ONE ④...
  • Page 39 OXYGEN 3000 PLUS · User Manual · ENG the closing command of the loudspeakers. That is possible to choose one or more microphones to cut the loudspeaker output of the CR “Control Room” by following this path: MENU / AUDIO / INPUTS / MIC / SPK-CUT (OFF, ST, CR, CR+ST) When you select CR, press down the knob to confirm the selection and the CR will show up in yellow color.
  • Page 40: Menu Control

    OXYGEN 3000 PLUS · User Manual · ENG 3.4. MENU CONTROL BUTTONS & DISPLAY 7" TFT COLOR DISPLAY 7’’ - 800X480 RESOLUTION The display is used to control the mixer setting and monitor all the parameters and it has its own configuration menu.
  • Page 41 OXYGEN 3000 PLUS · User Manual · ENG BUTTONS FOR THE MENU NAVIGATION 1) The MENU button switches from HOME to MENU. With this button, you can recall the mixer configuration menu. Buttons 2 and 3 (>> and <<) allow you to move between pages of parameters/functions on the same menu level.
  • Page 42: Outputs Display

    OXYGEN 3000 PLUS · User Manual · ENG MENU display parts 1. In this part of the display can see some useful elements and information depending on the location of the MENU. 2. From here you can browse all lists available in the menu.
  • Page 43: Menu

    OXYGEN 3000 PLUS · User Manual · ENG 4. MENU 4.1. AUDIO 4.1.1. SETTINGS INPUT MODE This menu allows you to configure the inputs or sources of the mixer to work in different modes, such as stereo or two mono channels.
  • Page 44: Surface Mode

    OXYGEN 3000 PLUS · User Manual · ENG SURFACE MODE SOURCE SEL ALWAYS ALLOWED: you can always switch between A/B channel sources whenever it’s pressed the GAIN knob. FADER SETTINGS FADER THRESHOLD The setting of this threshold parameter allows you to establish the minimum threshold of each fader, so that above it the channel is ON, and below it, the channel is OFF.
  • Page 45: Vj Pro Mode

    OXYGEN 3000 PLUS · User Manual · ENG VJ PRO MODE If you have the Axel Technology VJPRO Console software this will be the console Channel controllers of VJPRO. CTRL-SOURCE: The DJPro (Radio side) audio source is rooted automatically in the PGM. We suggest you select USB AUDIO-1.
  • Page 46: Inputs

    OXYGEN 3000 PLUS · User Manual · ENG 4.1.2. INPUTS You can set Input source parameters from the menu MENU / AUDIO / INPUTS by PUSH/RUTATE the knobs as in the following steps. From this level of the menu, you choose which input source you like to customize.
  • Page 47 OXYGEN 3000 PLUS · User Manual · ENG NAME: This parameter allows the assignment of a LABEL to the various input sources. It is not possible to have a LABEL of more than 8 characters. To change the microphone name and sign it as you like, it’s so easy way just rotate and push the knobs.
  • Page 48 OXYGEN 3000 PLUS · User Manual · ENG PHANTOM 48V: This option allows you to turn the phantom power 48V ON/OFF for use with microphones (if the microphone requires it, such as a condenser microphone). The Phantom is shown in the channel Set Panel.
  • Page 49: Adv. Settings

    OXYGEN 3000 PLUS · User Manual · ENG TB MIC: OFF: the microphone is not a Talkback mic. This selection can disable the microphone to disconnect it from the talkback connection. From CR to ST: talk with the Studio using this microphone.
  • Page 50 OXYGEN 3000 PLUS · User Manual · ENG MODE: This function has been added to prevent unauthorized people from activating or deactivating the equalizer. UNLOCKED: that is mean the equalizer is free and can activate or deactivate the equalizer from the F button on the surface.
  • Page 51 OXYGEN 3000 PLUS · User Manual · ENG BASS, BASS-MID, MIDDLE, MID-HIGH, HIGH: In OXYGEN the Parametric equalizers allow the adjustment of multi-band frequency equalizers which allow you to control the three primary parameters: AMPLITUDE, CENTER FREQUENCY, and BANDWIDTH. The amplitude of each band can be controlled by the GAIN knob.
  • Page 52 OXYGEN 3000 PLUS · User Manual · ENG DYN. COMP.: Dynamic range compression (DRC) or simply compression is an audio signal processing operation that reduces the volume of loud sounds or amplifies quiet sounds thus reducing or compressing audio signals in DYNAMIC RANGE.
  • Page 53 OXYGEN 3000 PLUS · User Manual · ENG PAN: This parameter changes the Input PAN. The parameter has a 1.0 dB step. N.B.: When you adjust the BAL/PAN parameter, you have a real-time change of the parameter value and a real-time perception of the BAL/PAN change. The Graphics will become white to indicate the parameter change, and they will become yellow again after the confirmation.
  • Page 54: Mic Automix

    OXYGEN 3000 PLUS · User Manual · ENG MIC AUTOMIX An automatic microphone mixer automatically reduces the strength of a microphone's audio signal when it is not being used. Automixers reduce extraneous noise picked up when several microphones operate simultaneously.
  • Page 55 OXYGEN 3000 PLUS · User Manual · ENG To change the source type from MONO to STEREO or on contrary you need to follow these steps: - MENU: MAIN / AUDIO / SETTING / INPUT MODE From this level of the menu, you choose which input MONO/STEREO source you like to customize.
  • Page 56: Usb-1, Usb-2

    OXYGEN 3000 PLUS · User Manual · ENG USB AUDIO 2 USB audio interface per each board The USB audio interface allows you to directly connect the PC to the Oxygen console, with no need for audio cards. in fact, the PC detects the console as a digital audio card with 2 stereo inputs and 2 stereo outputs for simultaneous playout and recording (Bidirectional).
  • Page 57: Digital Aes/Ebu

    OXYGEN 3000 PLUS · User Manual · ENG DIGITAL AES/EBU OXYGEN Digital Mixing Console has included digital audio input sources. The digital audio can connect to any digital audio source via AES/EBU. Stereo Input - XLR Female - Balanced Digital Connection (110Ω)
  • Page 58: Phone / Telco / Bt (Bluetooth)

    These three different kinds of implementations were been grouped all together. In fact, they have similarities on the source side. 3 kind of telephone connection is available on the full version of the OXYGEN 3000 Plus Digital console: 2x TELEPHONE (internal telephone...
  • Page 59: Integrated Hybrid Line

    OXYGEN 3000 PLUS · User Manual · ENG F button MODE: From here, you can change the way the F button communicates with the external hybrid and can select one of three choices available (NONE, GPIO, DEVICE) NONE: no action.
  • Page 60: External Telco Device

    OXYGEN 3000 PLUS · User Manual · ENG EXTERNAL TELCO DEVICE A phone call could be managed by an external TELCO DEVICE. To use the device with the console you have to connect the external hybrid to:  the RJ45 connector to the related port labeled as TELCO I/O GPIO.
  • Page 61: Additional Telco Lines

    OXYGEN 3000 PLUS · User Manual · ENG To manage TELCO 1 GPO signal set the TELCO 1 HOOK by the following submenu: MAIN / GENERAL / GPIO / GPO / TELCO 1 ADDITIONAL TELCO LINES It is possible to use 4 more additional TELCO lines (TELCO 2 / TELCO 3 / TELCO 4 / TELCO 5) by setting the console with the correct parameters.
  • Page 62 OXYGEN 3000 PLUS · User Manual · ENG ADDITIONAL TELCO OUTPUT clienfeed / N-1 logic OUT-2 (ANALOG-OUT-2) source could be configured as 2 different TELCO mono outputs: TELCO 2: ANALOG-OUT-2-L TELCO 3: ANALOG-OUT-2-R to use the 2 above signals as 2 separate telco output lines please set the related parameter as follow: MAIN / AUDIO / OUTPUTS / ANALOG / OUT-2 / source N-1 T2/T3: TELCO 2 caller and TELCO 3 caller can hear each other.
  • Page 63: Bluetooth

    OXYGEN 3000 PLUS · User Manual · ENG Bluetooth Oxygen has a Bluetooth connection. This allows airing the calls made via Skype, Teams, Whatsapp, or normal phone calls by a Smartphone and Tablet. Oxygen has two modes of Bluetooth connection: Mono Bidirectional to support phone calls.
  • Page 64: Tone Gen

    OXYGEN 3000 PLUS · User Manual · ENG TONE GEN. OXYGEN Digital Console comes with a built-in audio tone generator. The tone range is 30 Hz - 20 kHz and you can select it by following these steps: - MENU: MAIN / AUDIO / INPUTS / TONE GEN.
  • Page 65: Analog & Digital Outputs

    OXYGEN 3000 PLUS · User Manual · ENG You can set output parameters from the MENU: MAIN / AUDIO / OUTPUTS by PUSH/RUTATE the knobs as in the following steps. From this level of the menu, you choose which output you like to customize.
  • Page 66: Monitor (Spk & Hdp)

    OXYGEN 3000 PLUS · User Manual · ENG GAIN This cursor adjusts the output GAIN of the current DANTE output. The parameter has a 0.1 dB step for a minimum of -6.0 dB to a maximum of +6.0 dB. The default value is 0.0 dB.
  • Page 67: Channels

    OXYGEN 3000 PLUS · User Manual · ENG TALKBACK Control Room (CRM) Loudspeaker (SPK) and Headphone (HDP) (OFF, ON) Here you can disable/enable the TALKBACK communications in control room speakers. Normally the talkback is used to communicate between the mixer man and the people in the studio via headphones or speakers or vice-versa.
  • Page 68: Snapshot

    OXYGEN 3000 PLUS · User Manual · ENG 4.2. SNAPSHOT This function is useful to save and recall the settings. These settings are saved in the internal memory and it is not exportable. ] [MORE INFO SNAPSHOT: it’s able to save ten different PRESETS by selecting the position of the new save from 1 to 10 before saving it.
  • Page 69: Communications

    OXYGEN 3000 PLUS · User Manual · ENG 4.3.2. COMMUNICATIONS From the GENERAL SET part of the menu, you can set the communication parameters like IP, DNS, Date & Time, Time zone, and NTP server. The high flexibility in OXYGEN Digital console design gives you the full ability to set this terrific console as you like and as your audio projects are needed.
  • Page 70: Access Code

    OXYGEN 3000 PLUS · User Manual · ENG TIME ZONE From this parameter, you can set the TIME ZONE. You can set the right Offset to the UTC time. Network Time Protocol. This section contains all the settings related to NTP features. it is, in fact, possible to connect the device to an NTP server, and in this way, the device will synchronize its own date and time with the server.
  • Page 71: Light & Display

    OXYGEN 3000 PLUS · User Manual · ENG 4.3.4. LIGHT & DISPLAY From the following menu sub-sections, you can set the led colors and the led brightness. It is also possible to choose between the different HDMI output layouts available.
  • Page 72: Smart Keys

    OXYGEN 3000 PLUS · User Manual · ENG The Oxygen console allows you to set and manage 2 different kinds of outcoming IP commands:  The first SMART KEY kind could be managed by Oxygen FUNCTIONS buttons.  the second TRIGGER kind could be managed by OXYGEN channel sliders and related ON/OFF buttons.
  • Page 73: Service

    OXYGEN 3000 PLUS · User Manual · ENG 4.4. SERVICE 4.4.1. CONFIGURATION One of the characteristics of OXYGEN is that all settings can be saved on an external memory stick and can be called again when needed, and the settings can also be exported from one mixer to another.
  • Page 74: Software

    OXYGEN 3000 PLUS · User Manual · ENG 4.4.2. SOFTWARE UPGRADE MIXER FIRMWARE UPGRADE must connect the OXYGEN to the internet. To do this using the DHCP or static IP address, go to: MENU / GENERAL SET. / COMMUNICATIONS / TCP-IP / ADDRESS-1 or 2 / DHCP ]...
  • Page 75: Logs

    OXYGEN 3000 PLUS · User Manual · ENG VERSION FIRMWARE From the following section, you can read the parameters related to the firmware version. 4.4.3. LOGS the log file is a file that records events that occur in an operating system or other software runs.
  • Page 76: Surface Lock

    OXYGEN 3000 PLUS · User Manual · ENG 4.4.6. SURFACE LOCK This refers to a mode of operation in OXYGEN digital audio mixers where the surface of the mixer is locked, preventing any accidental or unauthorized changes to the mix settings.
  • Page 77: 187-Rj45-Mic

    OXYGEN 3000 PLUS · User Manual · ENG + 187-RJ45-MIC + 187-RJ45-MIC | SERVICE...
  • Page 78: 188-Rj45-Telco

    OXYGEN 3000 PLUS · User Manual · ENG + 188-RJ45-TELCO + 188-RJ45-TELCO | SERVICE...
  • Page 79: 189-Rj45-Line-In

    OXYGEN 3000 PLUS · User Manual · ENG + 189-RJ45-LINE-IN + 189-RJ45-LINE-IN | SERVICE...
  • Page 80: 190-Rj45-Line-Out

    OXYGEN 3000 PLUS · User Manual · ENG + 190-RJ45-LINE-OUT + 190-RJ45-LINE-OUT | SERVICE...
  • Page 81: Tech Specs

    OXYGEN 3000 PLUS · User Manual · ENG TECH SPECS Analog Balanced Microphone Inputs Connector RJ45 & XLR Balanced – EMI Suppressed Input Impedance 2,4 KΩ Nominal Input Level (sensitivity) -9/-66 dBu Max Input Level (clipping point) +9 dBu A/D conversion...
  • Page 82 OXYGEN 3000 PLUS · User Manual · ENG Digital Input Connector Balanced on 1 XLR – EMI Suppressed Input Impedance 110 KΩ Standard AES3 Audio Sample Rate 32/44.1/48/96/192 KHz with SRC Resolution 24 bit Dynamic Range (Converter Values) 124 dB...
  • Page 83 OXYGEN 3000 PLUS · User Manual · ENG Dante I/O Physical Connector Mini-PCI Power 3.3VDC @ 2W max Sample Bit Depth 16, 24 or 32 bits per sample Sample Rates (16x16 Versions) 44.1/48/88.2/96 kHz Sample Rates (32x32 Versions) 44.1/48/88.2/96 kHz...
  • Page 84 OXYGEN 3000 PLUS · User Manual · ENG Digital Output Connector Balanced on 1 XLR – EMI Suppressed Input Impedance 110 Ω Standard AES3 Audio Sample Rate 32/44.1/48/96/192 KHz Resolution 24 bit Dynamic Range (Converter Values) 124 dB PSTN Interface...
  • Page 85: Weee Directive - Informativa Raee

    OXYGEN 3000 PLUS · User Manual · ENG WEEE DIRECTIVE – INFORMATIVA RAEE In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to the point of sale or to your local municipal collection point for recycling.
  • Page 86: Warranty

    OXYGEN 3000 PLUS · User Manual · ENG EU:n sähkö- elektroniikkalaiteromudirektiivin (2002/96/EY) mukaisesti tätä elektroniikkalaitetta ei saa laittaa lajittelemattoman yhdyskuntajätteen sekaan. Hävitä laite palauttamalla se ostopaikkaan tai viemällä se elektroniikkaromun keräyspisteeseen. De acordo com a Directiva Europeia 2002/96/EC sobre resíduos sólidos de equipamento eléctrico e electrónico (WEEE), este produto eléctrico não pode ser deitado fora juntamente...

Table of Contents