Advertisement

Quick Links

Pacific
Towel rail
Models:
RFTR780
RFTR920
RFTRC920
RFTRC1320
NOTE
A qualified electrician must carry out the electrical installation of this towel rail. The electrical
installation must comply with current UK regulations. Any claim on the warranty could be invalid
if these requirements have not been met.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pacific RFTR780 and is the answer not in the manual?

Questions and answers

Summary of Contents for ATC Pacific RFTR780

  • Page 1 Pacific Towel rail Models: RFTR780 RFTR920 RFTRC920 RFTRC1320 NOTE A qualified electrician must carry out the electrical installation of this towel rail. The electrical installation must comply with current UK regulations. Any claim on the warranty could be invalid if these requirements have not been met.
  • Page 2: Table Of Contents

    CONTENT IMPORTANT INFORMATION ..........TECHNICAL DATA .
  • Page 3: Important Information

    IMPORTANT INFORMATION • Caution: parts of this product may become very hot and cause burns. You have to lend special attention in the presence of children and vulnerable people. • Children under 3 years of age should be kept away from this appliance unless they are under continuous supervision.
  • Page 4: Technical Data

    TECHNICAL DATA Power Dimensions (mm) Net Weight MODEL Color Shape Nº tubes HxWxD (kg) RFTR780W White Straight 860 x 500 x 120 RFTR920W White Straight 1000 x 500 x 120 RFTRC920W White Curved 1020 x 500 x 90 RFTRC1320W White Curved 1400 x 500 x 90 GENERAL INFORMATION...
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS ATTENTION! PLACE ALWAYS IN THE CORRECT POSITION LOCATION OF THE TOWEL RAIL It is essential to mount the towel rail with the control box on the lower right hand side. To avoid risks this appliance must be installed with the lowest heated rail at least 600mm above the floor. In bathrooms, the towel rail must never be installed in such a way that the switches and other control devices can be touched by a person in the bathtub or shower.
  • Page 6: Components

    COMPONENTS The components for fastening the towel rail to a wall are supplied in a bag together with the appliance. There are four support assemblies, each consisting of the following components: (A) 1 plastic tube Ø28 x 65mm + screw M5 (B) 1 plastic tube Ø20 x 55mm with threaded inserts (C) 1 screw M6 (D) 1 plastic retainer (conic 15º)
  • Page 7: Operating Instructions

    OPERATING INSTRUCTIONS Switching ON: Once the towel rail has been mounted on The control is based on six buttons and a TFT display. the wall and correctly connected to the mains electricity power supply, press the main On/Off Current time Set point temperature button on the left side of the towel rail control.
  • Page 8: Manual Programming

    MANUAL PROGRAMMING SET PROGRAM TEMPERATURES To assist with programming the TFT screen is To amend the temperature set points used in backlit and will stay illuminated for approximately the program mode, press and hold the CONFIG 10 seconds after the last button is pressed. (To button until the following screen appears: change the backlight time, see the section on CONFIG...
  • Page 9: Entering A Program

    Select TIME and press OK. Once correct PROGRAM The current set time is shown on the display, to selected, select “add Wednesday COPY change time move the underline to the hours and period” and press OK. The mode 00:00 23:59 press OK.
  • Page 10: Boost

    To make sure your program is running Press To open the DISPLAY menu, press and the OK/MODE button until is shown at the hold CONFIG until the menu appears, select bottom of the screen. SETTINGS and press OK, finally select DISPLAY and press OK.
  • Page 11: Programming With App

    PROGRAMMING WITH APP The screen will change to show the Lock screen and any button presses will be ignored and the To programme a towel rail with a locked screen displayed. Gateway the heater must be paired to the To unlock the keypad press and hold the + Gateway.
  • Page 12 The Open window setting EASY Mode is a simple EASY mode Open Window will turn the heating of the mode of operation where towel rail off if the unit detects by only the + and – buttons a rapid drop in temperature on the towel rail operate to over a short period of time.
  • Page 13: Password

    PASSWORD RUNBACK MODE The Password Function of the towel rail serves The towel rail comes with a Runback mode for a number of functions; Keylock, Advanced menu use when the heater will be installed in areas access and also Runback access when the where restricted user control is required.
  • Page 14: Setback

    MAX TEMPERATURE Note: The Runback settings menu is not available unless the Runback mode has been Temperature Runback turned on. setting allows the installer Runback Config Default time temperature Runback Setback Runback operate higher than the Runback Max. Temp. Settings 30 minutes, this can be temperature set-point to give Max Time...
  • Page 15: Error Codes

    Outside of the Runback period the temperature TROUBLESHOOTING will fall to the Setback temperature if the towel rail Wed. 11:00 If the power of the Lithium Set point: is not re-activated. (Building Fabric Protection) battery drops, in the screen, a small icon will remind the .5°C Runback ON, Setback ON, user that the battery is flat.
  • Page 16: Default Values

    DEFAULT VALUES Default mode: OFF Type of control: PID Temperature offset: 0°C Open window detection: Disabled Adaptive Start: Disabled Programming in one hour intervals, All programmed hours in anti frost mode Set point temperatures: • Anti-freeze 7°C • Eco 18°C •...
  • Page 17: Ecodesign Table

    With adaptive start control With distance control option ATC Electrical and Mechanical Head Office & Showrooms ATC House, Broomhill Drive, Tallaght, D24 EF99, Ireland. IRL Tel: +353 (0)1 4625111 UK Tel: +44 (0)203 5649164 Fax: +353 (1) 452 0887 Email: sales@atc.ie...
  • Page 18 NOTES...
  • Page 19 NOTES...
  • Page 20: Maintenance And Care

    MAINTENANCE AND CARE ATC towel rails require very little maintenance. The surfaces of the towel rail must not be cleaned with an abrasive product or those containing granular substances. We recommend regular cleaning with PH neutral products. In order to clean the towel rail, it is recommended that the electric power is switched off.