  • Page 1 ® ULTRAVIOLET WATER PURIFIERS Ballast Ballast Models 120v 50/60 Hz 230v 50/60Hz MIN-1 10-0508B 10-0504B MIN-1.5 10-0508B 10-0504B MIN-3 10-0508B 10-0504B Read and Follow All Safety Instructions. Save These Instructions. Installation, Operation & Maintenance Extensive Product Information Available at: ultraviolet.com buyultraviolet.com...
  • Page 2: Table Of Contents

    WARRANTY & PRODUCT REGISTRATION ...........................16 These instructions generally describe the installation, operation and maintenance of the MINIPURE MIN-1, MIN-1.5 and ® MIN-3 Models. Questions that are not specifically answered by these instructions should be directed to the Factory.
  • Page 3: Safety Warnings

    SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
  • Page 4: Product Application

    No tools are required. Always disconnect electrical power when changing lamp. rinCiPle of Peration The MINIPURE design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection ® chamber. The dosage, as it applies to ultraviolet disinfection, is a function of time and the intensity of ultraviolet radiation to which the water is exposed.
  • Page 5: Installation

    INSTALLATION oCation The water purifier is intended for indoor use only. The water purifier is designed to mount horizontally. The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier, should be between 35 F and 100 Electrical power supplied to the water purifier MUST match power requirements listed on the water purifier.
  • Page 6: Imensional Ata

    Figure 2 - MIN-1 and MIN-1.5 Dimensional Drawing MIN-3 Dimensional Drawing Table 2 - MINIPURE Dimensional Data ® Model Inlet/Outlet MIN-1 7-1/8” 10-7/8” 3-1/8” 2-1/2” 10-3/8” 3-5/8” 1/4”FNPT MIN-1.5 10-1/8” 15-13/32” 3-1/8” 2-1/2” 14-15/16” 3-5/8” 1/4”FNPT MIN-3 8-3/4” 16-17/32”...
  • Page 7: 50/60H

    1. Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there is any damage to the purifier, power cord or plug. All models, of the MINIPURE line of water purifiers, are shipped with the ®...
  • Page 8: Ptions

    Step 3 - Install Nut on Stud against Step 2 - Slide Ring Terminal Wire Assembly Step 1 - Install Nut on Stud Washer & Tighten with 7/16” Wrench onto Stud & Lock Washer over Ring Plug ballast into an approved Ground Fault Circuit Interrupt (GFCI) receptacle. Where a 2-prong or unprotected 3-prong receptacle is encountered, it must be replaced by a properly grounded Ground Fault Circuit Interrupt (GFCI) receptacle.
  • Page 9: Maintenance

    MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “Water Quality” in the “Product Application” section. Ordinary maintenance consists of: • Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service. •...
  • Page 10: Amp Amp

    50/60H .10-0508b / 230 50/60H .10-0504b z using ballast no z using ballast no Figure 4 - Lamp Replacement Step 1 - Disconnect Power to Water Purifier and Remove Ground Connector Step 2 - Remove End-Cap...
  • Page 11: Uartz Leeve Nstallation Leaning Or Eplacement

    uartz leeve nstallation leaning or ePlaCement Figure 5 - Quartz Sleeve Installation, Cleaning or Replacement 120v 50/60Hz (ballast no. 10-0508B) or 230v 50/60Hz (ballast no. 10-0504B) 120v (shown) 120v (shown) 120v (shown) Step 4 - Remove Gland Nuts Step 5 - Remove Washer & O-Rings Step 6 - Remove Quartz Sleeve IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GOGGLES OR A FACE SHIELD, AS WELL AS GLOVES.
  • Page 12: Q Uartz

    ePlaCement of roken uartz leeve IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GOGGLES OR A FACE SHIELD, AS WELL AS GLOVES. Broken Quartz is SHARP. It is recommended that protective goggles and gloves are worn when handling.
  • Page 13: 10-0504B)

    TROUBLESHOOTING Always disconnect power to the water purifier before performing any service or maintenance. IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel. Table 3 - Troubleshooting Problem Possible Cause Corrective Action Verify that the purifier is connected to a live Purifier not operating No electrical power power source.
  • Page 14: Technical Specifications

    TECHNICAL SPECIFICATIONS Table 4 - Technical Specifications Model: MIN-1 MIN-1.5 MIN-3 Flow Rate (GPM): Inlet\Outlet Size: 1/4”FNPT 1/4”FNPT 3 /4”MNPT Number of Lamps: Lamp Model No.: 05-1119-R 05-1366-R 05-1366-R Length: 10-7/8” 15-13/32” 16-17/32” Width: 2-1 /2” 2-1/2” 4-1/4” Height: 3-5/8”...
  • Page 15: Replacement Parts

    REPLACEMENT PARTS Figure 6 - Exploded View MIN-1, MIN-1.5, MIN-3 120v 50/60Hz using ballast no. 10-0508B, 230v 50/60Hz using ballast no. 10-0504B Table 5 - Replacement Parts MIN-1, MIN-1.5, MIN-3 120v 50/60Hz (ballast no.10-0508B), 230v 50/60Hz (ballast no.10-0504B) MIN-1 MIN-1.5 MIN-3 Item No.
  • Page 16: User Assistance

    This manual Fax: 631.273.0771 installation or use of this unit, contact describes the installation, operation, E-mail: info@ultraviolet.com and maintenance of the MINIPURE our offices, weekdays between 8:30 am ® Website: Ultraviolet.com Ultraviolet Water Purifier. and 5:00 pm Eastern Time, at: BuyUltraviolet.com...