Advertisement

Quick Links

SPARE PARTS DIAGRAM FOR
Water Boiler
Hydroboil Plus
HP003-107
First Choice Group
Blakeney Way, Kingswood Lakeside
Cannock, Staffs, WS11 8LD
TEL: 01543 577778 FAX: 01543504141
Email: enquires@firstchoice-cs.co.uk
Web: www.firstchoice-cs.co.uk

Advertisement

Table of Contents
loading

Summary of Contents for First Choice Zip Hydroboil Plus

  • Page 1 SPARE PARTS DIAGRAM FOR Water Boiler Hydroboil Plus HP003-107 First Choice Group Blakeney Way, Kingswood Lakeside Cannock, Staffs, WS11 8LD TEL: 01543 577778 FAX: 01543504141 Email: enquires@firstchoice-cs.co.uk Web: www.firstchoice-cs.co.uk...
  • Page 2 205561 Zip Hydroboil Plus 5 Litre Stainless Steel HP105 207562 Zip Hydroboil Plus 7.5 Litre White HP007 207561 Zip Hydroboil Plus 7.5 Litre Stainless Steel HP107 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00 Page 1 of 16...
  • Page 3 This page intentionally left blank Page 2 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 4: Table Of Contents

    All plumbing and electrical installations must comply with local authority requirements. Page 3 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 5: Read These Warnings First

    A suitable form of water treatment may be necessary. All plumbing connections must be made in accordance with local regulations. The Zip Hydroboil Plus instant boiling water heater is not intended for use by young children or infirm people without supervision.
  • Page 6: Step 1 - Positioning

    Install plumbing and wiring and prepare pipe ends and wiring ends as shown. Screw heater chassis to the wall using screws or bolts suited to the wall. Elbow Spout detail Page 5 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 7: Installation Procedures

    Turn power ON. After a short period, boiling water will be available and will be maintained close to boiling point thereafter. Initial heating periods are shown in the table on the left. Page 6 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 8: Wall Mounting Template Dimensions

    In order to help preserve our environment we ask that you dispose of this product correctly. Please contact Zip customer services for advice on 0845 602 4533 Page 7 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 9: Problem Solving

    Warning- the water may be boiling - show extra care. 5. Test that in every instance the electrical resistance does not exceed 1 ohm. Page 8 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 10: Tap Operating Procedures

    Tap Operation Safety feature. Zip Hydroboil Plus has a unique safety device designed to reduce the incidence of accidental operation of the tap.The tap can be “Locked” to prevent the Hydroboil Plus from dispensing hot water In order to “lock” the tap, ensure the safety button is protruding from the right hand side of the control panel and the...
  • Page 11: Operational Procedure Settings

    Low Light Mode is indicated by the Low Light symbol on the LCD. When the unit actually enters energy saver mode it is indicated by the Sleep Mode Indicator on the LCD. Page 10 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 12: Default Settings

    In Normal operation mode the LCD will display as follows: Note: The BOILING WATER symbol is not displayed until the water reaches temperature. Page 11 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 13: Configurational Mode

    CHANGE FILTER icon, the user must re-enter Configuration, set the Filter Expiration Time to OFF and return to Normal Operation. perational Page 12 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 14 If no action is sensed on the CSS’s for 20 seconds, the unit will revert to Normal Mode. After SAT OFF-TIME 2 pressing either CSS1 or CSS4 will revert the unit to Normal Mode. Page 13 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 15 Insulation Kit 5Litre SP90737 Insulation Kit 7.5Litre SP90130 Clips for Curled Tank Kit SP90744 PCB Kit Hydroboil 2006 SP90214 Sensor Sleep Mode Page 14 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 16: Spare Parts

    Spare Parts Page 15 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...
  • Page 17: Warranty And Contact Details

    Images in this booklet have Facsimile: 01362 692 448. been modified and may not be true representations of the finished goods. Page 16 of 16 Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00...

This manual is also suitable for:

Zip hp003-107