Bosch Professional GAS 35 L SFC+ Original Instructions Manual page 9

Hide thumbs Also See for Professional GAS 35 L SFC+:
Table of Contents

Advertisement

The vacuum cleaner is suitable for
WARNING
vacuuming dry substances, and
can also be used to vacuum liquids when taking appropri-
ate measures. The penetration of liquids increases the risk
of an electric shock.
Do not use the vacuum cleaner to vacuum combustible
u
or explosive liquids, such as petrol, oil, alcohol or
solvents. Do not vacuum hot or burning dust. Do not
operate the vacuum cleaner in areas subject to explo-
sion hazards. Dust, vapours and liquids can ignite or ex-
plode.
Only use the socket for the pur-
WARNING
pose stipulated in the operating
manual.
If you notice a foam or water leak,
WARNING
switch off the vacuum cleaner im-
mediately and empty the container. Otherwise, the va-
cuum cleaner can become damaged.
NOTE: The vacuum cleaner must only be stored in-
u
doors.
NOTE: Clean the liquid fill level sensors regularly and
u
check whether they are damaged. Otherwise, the
equipment may not function properly.
If operating the vacuum cleaner in a damp location is
u
unavoidable, use a residual current device (RCD). Use
of an RCD reduces the risk of electric shock.
Connect the vacuum cleaner to a properly earthed
u
power supply system. The socket and extension cable
must have a fully functioning protective conductor.
Always check the vacuum cleaner, cable and plug be-
u
fore use. Do not use the vacuum cleaner if you dis-
cover any damage. Do not open the vacuum cleaner
yourself. It should be repaired exclusively by a quali-
fied professional using only genuine spare parts. Dam-
aged vacuum cleaners, cables and plugs increase the risk
of electric shock.
Do not crush the cable or run the device over it. Do not
u
pull on the power cable to pull the plug out of the
socket or to move the vacuum cleaner. Damaged
cables increase the risk of an electric shock.
Pull the plug out of the socket before cleaning or per-
u
forming maintenance on the vacuum cleaner, making
tool adjustments, changing accessories or putting
Symbols and their meaning
Bosch Power Tools
away the vacuum cleaner. This safety measure prevents
the vacuum cleaner from being started accidentally.
Ensure that the workplace is well ventilated.
u
The vacuum cleaner should be repaired exclusively by
u
a qualified professional using only genuine spare
parts. This will ensure that the safety of the vacuum
cleaner is maintained.
WARNING
Emptying and maintenance procedures, including the
disposal of dust collectors, should only be carried out by
professionals. Suitable protective equipment is re-
quired. Do not operate the vacuum cleaner without the
complete filter system. Otherwise, you are putting your
health at risk.
Before using the equipment for the first time, check
u
that the vacuum hose is in perfect condition. Leave
the vacuum hose fitted to the vacuum cleaner while
doing this so that no dust escapes accidentally. Other-
wise, you may end up inhaling dust particles.
Do not sit on the vacuum cleaner. You can damage the
u
vacuum cleaner this way.
Take care when using the power cable and the vacuum
u
hose. Improper use of these can put other people at risk.
Do not clean the vacuum cleaner by spraying a jet of
u
water directly at it. Water entering the top of the va-
cuum cleaner will increase the risk of electric shock.
Products sold in GB only:
Your product is fitted with an BS 1363/A approved electric
plug with internal fuse (ASTA approved to BS 1362).
If the plug is not suitable for your socket outlets, it should be
cut off and an appropriate plug fitted in its place by an au-
thorised customer service agent. The replacement plug
should have the same fuse rating as the original plug.
The severed plug must be disposed of to avoid a possible
shock hazard and should never be inserted into a mains
socket elsewhere.
Symbols
The following symbols may provide you with important in-
formation pertaining to the use of your dust extractor. Please
take note of the symbols and their meaning. Knowing what
these symbols mean will help you to use your extractor more
effectively and more safely.
WARNING! Read all the safety instructions and general instructions. Failure to ob-
serve the safety instructions and general instructions may result in electric shock, fire
and/or serious injury.
Dust extractor from dust class L in accordance with IEC/EN 60335-2-69 for the dry
vacuuming of harmful dusts with an exposure limit of > 1 mg/m
English | 17
The vacuum cleaner contains dust
particles that pose a risk to health.