Operation Manual for Power Supply PWR-3040 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.02-8.12...
Packing list 1x Mini Pro 300V Power Supply 1x Power Cord 1x Instruction Manual Signed by: Date: is liable for all missing or damaged parts / accessories within 7 days after customer received this instrument package. Please contact M immediately regarding this issue. If no response within such time period from consignee party, that will be consignee party’s whole responsibility.
Warning Power Supply has been tested and found to comply with the limits for the CE regulation. Also, it is RoHS compliant to deliver confident product which meets the environmental directive. These limits are designed to provide reasonable protection against harmful interference when the instrument series is operated in a commercial environment.
Page 4
of explosion, implosion or release of toxic or flammable gases arising from overheated materials. 11. The unit shall be operated only by qualified personnel. Safety Information Use high level of precaution against any electrical device. Before connecting the electrical supply, check to see if the supply voltage is within the range stated at the rating label, and see to it that the device be seated firmly.
Page 5
Avoiding Damage to the Instrument 1. Do not attempt to operate the device if damage is suspected. 2. Protect this unit from physical damage, corrosive agents and extreme temperatures (direct sunlight, etc.). 3. For proper ventilation and safety concerns, keep at least 10 cm of space behind the instrument, and at least 5 cm of space on each side.
Page 6
Indicates disposal instruction. DO NOT throw this unit into a municipal trash bin when this unit has reached the end of its lifetime. To ensure utmost protection of the global environment and minimize pollution, please recycle this unit.
Section 1 Introduction 1.1 Overview Power Supplies are recognized as unique power supplies equipped with very powerful specifications to cover the majority of electrophoresis applications on the market. Sufficient and accurate output voltages, two terminal pairs, and its compacted size can deliver accurate and reliable experimental results from one experiment to another.
1.2 Product Description & Feature Combining small size and versatility, the newly redesigned power supply is an ideal choice for any researcher. Capable of providing constant current or constant voltage in 1 mA or 1 V steps, the unit is perfectly suited to run both vertical polyacrylamide and horizontal agarose electrophoresis experiments.
Section 2 Technical Specification Cat. No Output Voltage / Inc. 10 - 300V / 1V Output Current / Inc. 10 - 400mA / 1mA Max. Watt Output Type Constant Voltage or Constant Current Control Microprocessor controller Terminal Pairs 2 Pairs Timer 1 - 999 minutes with alarm, continuous Safety Device...
Section 3 Installation Instructions Power Supply is actually a pre-installed instrument. As long as it is placed on a sturdy and level surface in a safe, dry place, and further connects with well-prepared electrophoresis system, it is ready for operation. Section 4 Operation Instructions 4.1 Control interface You will be able to find six buttons and 4 LED indicators from the faceplate.
– Select voltage value – Select current value – Timer button – Increase the Voltage, Current or Time – Decrease the Voltage, Current, or Time – Start or stop the unit 4.2 Start the operation Note: To operate under constant voltage or constant current modes, adjust the other parameter to the maximum value.
Page 13
*To set constant current, press , and LED indicator should light up. 6. Adjust the output value by pressing the button. 7. After adjusting your constant mode output value, switch to the other parameter and set it to maximum. 8. Timer Setting: After setting the current or voltage output value, press the Timer button, and then press key or key to adjust timer...
Section 5 Trouble shooting and Maintenance Many operating problems may be solved by carefully reading and following the instructions in this manual accordingly. Some suggestions for troubleshooting are given below. Should these suggestions not resolve the problem, contact our SERVICE DEPARTMENT or a distributor in your region for assistance. If troubleshooting service is required, please include a full description of the problem.
Page 15
2. Call Technical Service or e-mail to mrc@mrclab.com 3. If the unit must be shipped back for repair, contact MRC or the distributor for a Return Authorization Number and shipping instructions. The unit will be repaired and returned to you as quickly as possible.
Page 16
4. Place the fuse holder back into the compartment. 5. Snap the cover closed. Maintenance PWR-3040 Power Supply uses all solid-state components and should require no maintenance or recalibration under normal use. If the unit must be returned for repair, contact our SERVICE DEPARTMENT or your local...
Need help?
Do you have a question about the PWR-3040 and is the answer not in the manual?
Questions and answers