  • Page 1 ™ levelsmart Wireless Autofill USER INSTRUCTION MANUAL Instruction Manual English...
  • Page 2: Table Of Contents

    CONTENTS Supporting Documents & Media ..................3 Description ........................3 What’s in the Box .......................5 Installation and Setup ......................6 Install the Valve .............................6 Install and connect the Valve Controller ....................7 Connect the Antenna ..........................7 Install the Power Supply and connect to the Valve Controller ............8 Pair the Level Sensor and Valve Controller ..................8 Mount the Level Sensor ........................9 Mount the Antenna ..........................10...
  • Page 3: Supporting Documents & Media

    DESCRIPTION LevelSmart is a sophisticated, yet simple to install, wireless control system designed to maintain the desired water level in Pools, Spas, Water Features, Ponds, or Tanks. Unlike other level control systems, LevelSmart does not require underground wiring or plumbing from the equipment pad to the body of water.
  • Page 4 SENSOR Fig.1.0 The overall principle of operation of the LevelSmart system is as follows: During setup, the Level Sensor is taught the desired water level. When the Level Sensor detects a low level, it communicates this condition to the valve controller via a wireless signal. The valve controller opens the water supply valve for 7 minutes to restore the desired level.
  • Page 5: What's In The Box

    WHAT’S IN THE BOX LevelSmart valve LevelSmart level sensor Automatic valve Antenna controller Accessory kit: epoxy, Power supply Antenna extension Quick Start Guide (x2) wire nuts, (x2) cable (optional) screws ™ levelsmart Wireless Autofill...
  • Page 6: Installation And Setup

    An appropriately sized adapter with a 1” female thread should be glued into the socket of the ‘T’ . A short 1” NPT nipple should be threaded into the adapter and the downstream side of the valve threaded onto the other end of the nipple. ™ levelsmart Wireless Autofill...
  • Page 7 ¾” male NPT to ¾” MHT (male hose thread) adapter. Now connect a suitable length garden hose from the valve to a spigot. If the spigot serves another garden hose, install a ‘Y’ and connect both the LevelSmart hose and the existing garden hose.
  • Page 8 You will now see three flashes of the green LED at the top center of the Level Sensor, this indicates that the Level Sensor has initiated its pairing sequence with the Valve Controller. ™ levelsmart Wireless Autofill...
  • Page 9 It is critical to thoroughly clean / scrub the area where the Level Sensor is to be installed. Now thoroughly dry the area above the water line where the Level Sensor is to be mounted. ™ levelsmart Wireless Autofill...
  • Page 10 Make sure to not mount the Antenna on or within 12 inches of metal. h) Set and calibrate the water level This step will teach the LevelSmart system the desired water level that it is to maintain. With the water at its desired level, place the magnet over the bottom right corner of the Level Sensor for 2 seconds before removing it (see Fig.1.4).
  • Page 11: Testing The Valve After Pairing

    ACTION LED illuminates. You may also hear water flowing through the valve. At the end of five (5) seconds, the ACTION LED will go off and the valve will close. ™ levelsmart Wireless Autofill...
  • Page 12: Adjusting The Water Level

    LED in the top center position. • Observe the Valve Controller’s green Sensor LED flash for approximately one minute as it recalibrates the new water level. • Ensure that the green Sensor LED turns solid green after the one minute. ™ levelsmart Wireless Autofill...
  • Page 13: Valve Flow Control Adjustment

    A fully closed flow control knob will result in zero flow. Other features of the Valve are as follows: a. Solenoid. This is operated electrically by the LevelSmart Valve Controller. The solednoid can be operated manually by opening it ¼ turn counterclockwise to allow flow through the valve.
  • Page 14: Troubleshooting

    The sensor should only be mounted with epoxy provided in the Sensor mounted with Overfilling LevelSmart kit. Check that the level sensor is not cracked. If needed, screws contact H2flow Controls for further assistance. Use of out of spec valve Use only the components supplied with the LevelSmart unit.
  • Page 15: Notes

    If not, use a voltmeter check for 24 VAC at wire nuts Water level not being maintained ler not operating going to valve. If 24 VAC present, valve solenoid is defective. Contact H2flow. If 24 VAC not present when Action LED illuminated, ten Valve Controller is defective. Water level calibration...