READ THE LABEL AND OPERATING MANUAL BEFORE USING THIS PRODUCT
UVantage_InsallationManual_Canadian-8inch_12-5-22.indd 1
UVantage_InsallationManual_Canadian-8inch_12-5-22.indd 1
i n s t a l l a t i o n m a n u a l
8 - i n c h
12/5/22 9:52 AM
12/5/22 9:52 AM

Advertisement

loading
Need help?

Need help?

Do you have a question about the Rexnord UVANTAGE PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Regal Rexnord UVANTAGE PLUS

  • Page 1 READ THE LABEL AND OPERATING MANUAL BEFORE USING THIS PRODUCT i n s t a l l a t i o n m a n u a l 8 - i n c h UVantage_InsallationManual_Canadian-8inch_12-5-22.indd 1 UVantage_InsallationManual_Canadian-8inch_12-5-22.indd 1 12/5/22 9:52 AM 12/5/22 9:52 AM...
  • Page 2 i n t e n d e d u s e o f t h e d e v i c e UV AIR TREATMENT TECHNOLOGY HELPS REDUCE AIRBORNE BACTERIA AND VIRUSES* *The UVantage PLUS™ device is intended to be installed in existing residential and commercial HVAC systems. This UV device helps to reduce airborne bacteria and viruses.
  • Page 3 s p e c i f i c a t i o n s Input Voltage: 81104299: 100 - 240VAC 81104300: 120 - 277VAC Rated Input Frequency: 50/60Hz 0.9A Max Rated Current: Output Voltage: 24 VDC Power Consumption: AC input power up to 32W UVC LEDs Lamp Type: UVC Wavelength:...
  • Page 4 p r e f e r r e d m o u n t i n g l o c a t i o n s SUPPLY AIR DUCT Optional Location 6” RETURN AIR DUCT Suggested Location Above image is for all metal duct wall. For Flex duct, duct board, or drywall applications, proposed option of mounting the device at the apex of the evaporator coil.
  • Page 5 s a f e t y g u i d e l i n e s PRECAUTIONS indicates a hazard which, indicates a hazard which, A WARNING A CAUTION if not avoided, could result in serious injury if not avoided, could result in minor or or death.
  • Page 6 i t e m s i n c l u d e d f o r i n s t a l l a t i o n Control Cover Qty 1 Duct Plate Qty 1 LED Module Qty 1 Lead Assembly Qty 1 Screw...
  • Page 7 i n s t a l l a t i o n DO’s DON’Ts ✓ Disconnect all power supplies to the ✗ Don’t attempt to look at the UVC HVAC unit and UVantage PLUS™ module LED module while in operation. (hereafter referred to as “LED module”) before beginning any servicing.
  • Page 8 i n s t a l l a t i o n 1. Use template to mark the cut-pattern on the duct surface. It is suggested to align the template centered in the ductwork. Ensure there is enough duct depth (minimum 10 inches) before proceeding with installation.
  • Page 9 i n s t a l l a t i o n 3. Mount the gasket on the duct wall. 4. Install the wall plate to the duct surface along with the gasket using the 4 self-threaded screws where actual template mark was drawn. Recommended mounting torque for the screws is 0.4 ~ 0.5 N-m The direction of the mounting should...
  • Page 10 i n s t a l l a t i o n 5. Connect the wire harness to the LED module. 6. Insert the LED module through the hole of the wall plate and rotate it counter-clockwise to lock the LED module. Don’t touch UVC LEDs with bare hand.
  • Page 11 i n s t a l l a t i o n 7. Connect the LED module harness to the control cover as shown in the image. SAFETY SWITCH 8. Snap the control cover firmly to the wall plate. Visit regalrexnord.com/uvantage-plus-canada for additional information | UVantage_InsallationManual_Canadian-8inch_12-5-22.indd 11 UVantage_InsallationManual_Canadian-8inch_12-5-22.indd 11 12/5/22 9:52 AM...
  • Page 12: Green Led

    i n s t a l l a t i o n 9. Connect the 24V adapter plug to the DC jack on the control cover and plug the power supply into an outlet or control wiring depending on the Hardwired Power Wall Plugin Power application requirements.
  • Page 13 t r o u b l e s h o o t i n g Status Condition Troubleshooting Indicator Unit ON No action required. 1. Verify the system is receiving proper line voltage. 2. If the line voltage reading is good, check Unit OFF / Power for any loose connections of the power Failure...
  • Page 14 t r o u b l e s h o o t i n g Status Condition Troubleshooting Indicator 1. Verify the Control unit is mounted properly without any loose fittings on the duct wall, so Purple FLASH Safety Switch Error that safety switch holds with wall plate firmly.
  • Page 15 f a q ’ s 1. What is UVC? UVC refers to an ultraviolet light with a wavelength between 200-280 nm. The light in this wavelength can be used for germicidal irradiation in a HVAC system. 2. Where should the UVantage PLUS™ product be installed in the HVAC system? The UVantage PLUS device can be installed safely in all the duct works as highlighted in ™...
  • Page 16: Limited Warranty

    Ultraviolet radiation may cause eye and skin irritation. Avoid exposing eyes and skin to ultraviolet radiation. Regal Rexnord and UVantage PLUS are trademarks of Regal Rexnord Corporation or one of its affiliated companies. Regal Rexnord Corporation, Climate Solutions 1946 W. Cook Road, Fort Wayne, IN 46818, United States Designed by Regal Rexnord Corporation.