Download Print this page

Sealey Siegen S0100 Instructions page 2

Air impact wrench 1/2 sq. drive

Advertisement

couplings.
4.2.
4.2.1.
Vibration may cause failure if a quick change coupling is connected directly to the wrench.
4.2.2.
to overcome this, connect a leader hose to the wrench. A quick change coupling may then be used to connect the leader hose to the
air line recoil hose. See figs. 1 & 2.
fig 1
5. OperAtiOn
o
wArninG! ensure you read, understand and apply safety instructions before use.
5.1.
Only use impact sockets which are specifically designed for use with a impact wrench.
dO nOt use worn or damaged sockets.
5.2.
connect the wrench to the air hose see section 3.
5.3.
Place the socket over the subject nut and depress the trigger to operate the wrench.
5.4.
to change direction, push the button above the handle. direction of "r" for reverse and "f" for forward.
5.5.
The flow of air may be regulated by adjusting flow valve at the base of the handle.
dO nOt use any additional force upon the wrench in order to loosen/tighten a fixing.
8
dO nOt allow wrench to free run for an extended period of time as this will shorten bearing life.
8
6. mAintenAnce
wArninG! disconnect wrench from air supply before changing accessories, servicing or performing maintenance. replace or repair
damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
6.1.
if the air system does not have an oiler then lubricate the air wrench daily with a few drops of sealey air tool oil dripped into the air
inlet.
6.2.
check and top up the gearbox by removing grub screw located on the side of the body adjacent to the trigger.
6.3.
clean the wrench after use.
6.4.
loss of power or erratic action may be due to the following:
a) excessive drain on the air line. moisture or restriction in the air pipe. incorrect size or type of hose connectors. to remedy, check the
air supply and follow instructions in section 3.
b) Grit or gum deposits in the wrench may also reduce performance. if your model has an air strainer (located in the area of the air
inlet), remove the strainer and clean it. flush the wrench out with gum solvent oil or an equal mixture of sAe no 10 oil and paraffin.
Allow to dry before use.
6.5.
for a full service contact your local sealey service agent.
6.6.
When not in use, disconnect from air supply, clean wrench and store in a safe, dry, childproof location.
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
when the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
impOrtAnt: no liability is accepted for incorrect use of this product.
wArrAntY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack sealey limited
environmental protection
sole uK distributor, sealey Group.
Kempson Way, suffolk Business Park,
Bury st. edmunds, suffolk.
iP32 7Ar
Original Language Version
01284 757500
01284 703534
s0100 | issue 2 17/03/17
fig 2
www.sealey.co.uk
web
sales@sealey.co.uk

Advertisement