Download Print this page

LG 32LG40-UG Service Manual page 17

Advertisement

3. No OSD (Module Power Sequence)
Vcc
(5V)
T
Va
Vs
DISPEN
Symbol
Time interval between 90% of Vcc and 10% of Vs
T
On
Time interval between 10% of Vs and 90% of Vcc
T
Off
T
VaR
T
VaF
T
VsR
T
VsF
T
+
Time interval between 90% of Vcc and 90% of Vs
on
T
VsR
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
On
T
VaR
T
VsR
Min
Power_on
100ms
3 Sec
Description
when Power On
when Power Off
Rising Time of Va (10% to 90%)
Falling Time of Va (90% to 10%)
Rising Time of Vs (10% to 90%)
Falling Time of Vs (90% to 10%)
when Power On
Normal Display
- 17 -
T
Off
T
VaF
T
¢— 1)
VsF
Power_off
3 Sec
Min.
2Frame(Recommend: 2 sec)
Min.
Max.
500
-
20
-
10
300
50
300
100
800
90
500
600
2000
LGE Internal Use Only
unit
msec
msec
msec
msec
msec
msec
msec

Advertisement