Austria, 4600 Wels, Europastraße 45, T: +43 7242 698-0, M: office@moltoluce.com
[MM]
350°
54,2
54
844
2
2
7
7
5
5
10
10
4
4
9
9
8
8
3
3
1
1
6
6
technical information / manufacturing note
technical information / manufacturing note
01
drawing updated
00
first release
19.05.2022
Seyrkammer
01
drawing updated, P2022-0354 becomes 149-001xxxxxxxxx
05.04.2023
Seyrkammer
rev.
description
checked by
00
first release
19.05.2022
Seyrkammer
checked date
rev.
description
REVISIONS-HISTORY
checked date
checked by
threads must be free of coating
REVISIONS-HISTORY
all dimensions and tolerances related uncoated surfaces
all dimensions and tolerances related uncoated surfaces
max. thickness of coating: 120µm
VARIDO 2
1 / 2
1
MONTAGE | MOUNTING | MONTAGGIO | MONTAGE
2
IP 20
25°C
SURFACE KEY
SURFACE KEY
MAGENTA
MAGENTA
visible (general) surface
visible (general) surface
RED
70-120µm (main surface)
RED
70-120µm (main surface)
GREEN
GREEN
40-120µm (secondary surface)
40-120µm (secondary surface)
CYAN
0-120µm (tertiary surface)
CYAN
0-120µm (tertiary surface)
BLUE
BLUE
only powdermist allowed
only powdermist allowed
ORANGE
free of coating
ORANGE
free of coating
VIOLETT
VIOLETT
high gloss
high gloss
WITHOUT COLOUR
raw
WITHOUT COLOUR
raw
3
1
7
149,1,x
1
bracket
7
149,1,x
bracket
2
1
149,2,x
carrier plate
2
1
149,2,x
carrier plate
3
1
149,3,x
adapter
3
1
149,3,x
adapter
4
1
149,4,x
spagnolet
4
1
149,4,x
spagnolet
5
1
30-849880
5
driver
1
30-849880
driver
6
3
300,107,x
6
grid
3
300,107,x
grid
7
1
NT-000000033
7
slotted set screw
1
NT-000000033
slotted set screw
8
2
NT-000000202
8
Pan head with Torx
2
NT-000000202
Pan head with Torx
DE: Die Phase vor dem Einbau der Leuchte einstellen. Wenn die 3-Phasen-Schiene unter Spannung
9
3
d2347
optics
9
3
d2347
optics
10
3
pcb0237
board
10
3
pcb0237
board
pos
piece
article number
description
steht, darf die Phase nicht gewechselt werden. Die Phase im eingeschalteten Zustand NICHT
pos
piece
article number
description
part list
part list
general manufacturing tolerances
general manufacturing tolerances
drawn by
drawn by
wechseln. | EN: Adjust the phase before installing the lamp. If the 3-phase rail is under tension,
DIN ISO 2768-mK general tolerances
luksey
®
DIN ISO 2768-mK - general tolerances
luksey
®
material
creation date
material
creation date
29.03.2022
29.03.2022
weight
description
surface
drawing number
description
drawing number
do not change the phase. DO NOT change the phase when it is switched on. | IT: Impostare la fase
weight
surface
1,065 kg
482895 mm^2
luminaire profile
1,065 kg
483082 mm^2
luminaire profile
ENG000025593
ENG000025593
surface finish
surface finish
N/A
N/A
article number
article number
P2022-0354
surface according ISO 1302
149-001xxxxxxxxx
undimensioned edges
surface according ISO 1302
undimensioned edges
according DIN ISO 13715
prima di installare la lampada. Quando il binario trifase è sotto tensione, la fase non deve essere
according DIN ISO 13715
-0,2
+0,2
sheet 1 of 1
scale
sheet 1 of 1
-0,2
+0,2
The unauthorized and / or against the rules use of these documents
scale
The unauthorized and / or against the rules use of these documents
maximum thickness of coating: 120µm
1 : 3
and possible attachment are not permitted and are judicially pursued
A3
1 : 3
A3
and possible attachment are not permitted and are judicially pursued
modificata. NON cambiare la fase in stato "acceso" (on). | FR: Réglez la phase avant l'encastrement
du luminaire. Lorsque le rail triphasé est sous tension, la phase ne doit pas être modifiée. Ne PAS
changer la phase lorsque le luminaire est allumé.
CLICK
Phasen einstellbar. | Phases
adjustable. | Fasi regolabili. |
Phases réglables.
4
Kann bei Bedarf zwecks Ausrichtung demontiert werden. | Can be dismantled for alignment
if necessary. | Se necessario è possibile smontarlo per riorientarlo. | Démonter en cas de
besoin pour le réglage.
5
Bei Bedarf Gewindestift fixieren. | Fix grub screw if required. | Se necessario fissare la vite
filettata. | Démonter en cas de besoin pour le réglage.
1
DEMONTAGE | REMOVAL | SMONTAGGIO | DÉMONTAGE
| 25 | 04 | 2023
2
1
CLICK
149-Varido 2 REV 01
Need help?
Do you have a question about the VARIDO 2 and is the answer not in the manual?
Questions and answers