Advertisement

Available languages

Available languages

ANVÄNDARHANDBOK
OPERATING INSTRUCTIONS
Luftrenare
Air cleaner
A500
A1000
A2000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A500 and is the answer not in the manual?

Questions and answers

Summary of Contents for pullman Ermator A500

  • Page 1 ANVÄNDARHANDBOK OPERATING INSTRUCTIONS Luftrenare Air cleaner A500 A1000 A2000...
  • Page 2 Bäste kund, Tack för att ni valt Pullman-Ermator som leverantör. Vi önskar er lycka till med er nya luftrenare A500/A1000/A2000 och hoppas att den motsvarar era förväntningar. Vi tillverkar produkter sedan 1966 för professionell stofthantering och har genom åren erhållit en gedigen kompetens inom området.
  • Page 3 Uppackning Var noga med att kontrollera att luftrenaren är oskadad att inga synliga märken finns på sladden. Säkerhetsföreskrifter Handhavande Varning  En elkabel som har klämskador eller torrsprickor kan vara farlig att använda och skall omedelbart bytas ut. Risk för personskada. Varning ...
  • Page 4 Absolutfiltrets drifthållbarhet minskar och kan helt förstöras om det utsätts för vatten Filterindikator A500/A1000/A2000 är utrustad med filterindikatorer med varningslampa. Indikatorerna mäter tryckfallet över absolutfiltret. Vid för högt tryckfall tänds en orangefärgad lampa och indikerar att filterbyte är nödvändigt för att erhålla full effekt på luftrenaren. Vid för lågt tryckfall tänds en Röd lampa (även ljud) och indikerar att Hepa filtret är trasigt och omedelbart måste bytas ut.
  • Page 5 10085 Hepafilter 1 st A2000 För beställning av reservdelar, kontakta återförsäljare eller Pullman Ermator AB direkt. Garanti På samtliga Pullman-Ermator luftrenare med tillbehör gäller 12 månaders fabriksgaranti avseende material/tillverkningsfel. Med maskinen medföljer en garantisedel som efter returnerande till Pullman-Ermator AB utökas garantin till 36 månader.
  • Page 6 Felsökning Luftrenaren A500/A1000/A2000 är konstruerad och anpassad för en krävande miljö och uppgift, men användaren bör dock beakta att aggregaten innehåller precisionstillverkade komponenter som bör skyddas mot hårda slag och stötar. Filter, tätningar, infästningar och anslutningar är omsorgsfullt anpassade och utvalda för operatörens arbetsmiljö. Det är därför naturligtvis av stor vikt att operatör och servicepersonal behandlar aggregatet med insikt och kunskap, detta för att maskinen skall tjäna...
  • Page 7 Notice! These instructions are only for the air cleaner type Pullman-Ermator A500/A1000/A2000. The air cleaner, Pullman-Ermator A500/A1000/A2000 can only be used with dry, non-explosive materials. Pullman-Ermator will not be held responsible if the air cleaner is used for other applications or has been used in ways other than those outlined in this instruction manual.
  • Page 8: Safety Instructions

    Unpacking When unpacking the machine, please check that the air cleaner has not been damaged in transport. Safety Instructions Handling Warning  Cables damaged through crushing or splitting can be dangerous if used and should be replaced immediately. Risk of personal injury. Warning ...
  • Page 9: Filter Indicator

    The absolute filters cannot be cleaned and must be replaced when full. Filter indicator A500/A1000/A2000 has two filter indicators connected to a warning light which measures the pressure drop over the filter. If the pressure drop is too high, a orange lamp light up, indicating that the absolute filter should be changed.
  • Page 10: Warranty

    Accessories PART NO. DESCRIPTION No./machine Machine 200900275 Coarse filter 1 pc A500/A1000 200700532 Hepafilter 1 pc A500/A1000 200900224 Coarse filter 1 pc A2000 10085 Hepafilter 1 pc A2000 Contact your local representative for other spare parts. Warranty All Pullman-Ermator devices and accessories have a 12-month factory warranty for material and manufacturing defects.
  • Page 11: Problem Solving

    PROBLEM SOLVING The A500/A1000/A2000 is designed and manufactured for severe environments and tasks, but the user must note that the machine components must be protected from knocks and blows. Filter and sealing connections are carefully chosen to serve the operator. Therefore, the machine must be handled with care if it is to work correctly for many years.
  • Page 12: Tekniska Data

    TEKNISKA DATA TECHNICAL DATA A500 A1000 A2000 MÄRKSPÄNNING 230 VAC,1-fas (1-phase) 230 VAC,1-fas (1-phase) 230 VAC,1-fas (1-phase) Voltage EFFEKTUTTAG 2 lägen 280 W (full speed) 550 W (full speed) 750 W (full speed) Power MAX LUFTMÄNGD 2 lägen 500 m...
  • Page 13 Försäkrar under eget ansvar att maskinen Declare under our sole responsibility that the machine Certifie sous sa propre responsabilité que le produit ciaprès Versichern auf eigener verantwortung, dass das Produkt Forsikrer under eget ansvar at maskinen A500 Nr./No: 1200407 0001-xxxx A1000 Nr./No: 0900061 0001-xxxx A2000 Nr./No: 0900062 0001-xxxx...
  • Page 14 A500...
  • Page 15 PRE-FILTER PROTECT COVER ex.A1000 201000014 PRE-FILTER 12X12X1 INCH ex.A1000 201100218 FROTN FRAME COVER FOR A1000 ASSEMBLY 200700532 FILTER OF A1000 201100220a FAN ASSEMBLY KIT (ex.A500) 201000367 RUBBER FOOT KIT 201000426 LOCK SET ex.A1000 201000417 AIR OUTLET SET EX A1000 201000418 PRESSURE SENSOR SET ex.
  • Page 16 A1000 Revision 4...
  • Page 17 A1000 NUMBER DESCRIPTION QTY. 201100213 PRE-FILTER PROTECT COVER ex.A1000 201000014 PRE-FILTER 12X12X1 INCH ex.A1000 201100218 FROTN FRAME COVER FOR A1000 ASSEMBLY 200700532 FILTER OF A1000 201200274 FAN ASSEMBLY KIT (ex.A1000) 201000367 RUBBER FOOT KIT 201000426 LOCK SET ex.A1000 201000417 AIR OUTLET SET EX A1000 201000418 PRESSURE SENSOR SET ex.
  • Page 18 A2000 Revision 4...
  • Page 19 A2000 NUMBER DESCRIPTION QTY. 201100209 PRE-FILTER PROTECT COVER ex.A2000 201100214 FRONT FRAME COVER FOR A2000 SUB ASSEMBLY 201000015 PRE-FILTER OF A2000 10085 FILTER OF A2000 201200288 FRONT FAN INLET COVER KIT (ex.A2000) 201200284 FAN ASSEMBLY KIT (ex.A2000) 201000248 PRESSURE SENSOR SET (0-500) ex.A2000 201000427 AIR OUTLET SET ex.A2000 201200275 ALARM YELLOW LAMP 230 KIT 201100228 SOUND ALARM 80dB RED LAMP...
  • Page 20 Noteringar/Comments ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ ______________________ Revision 4...

This manual is also suitable for:

A1000A2000

Table of Contents