TABLE OF CONTENTS SECTION ITEM PAGE Safety Precautions………………………………………………………... 2 General Installation Instructions…………………………………………. 4 Specifications……………………………………………………………… 4 Lighting Instructions………………………………………………………. 7 Maintenance………………………………………………………………. 8 Conversion………………………………………………………………… 9 Replacement Parts Lists & Exploded Views…………………………… 11 Warranty…………………………………………………………………… 16 LOCATION OF DATA PLATE The data plate for the gas open burner range is located on the right side panel. IMMEDIATELY INSPECTFOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading.
GAS PRESSURE The appliance and it’s individual shutoff valve (to be supplied by user) must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.45 kPa). NOTE: Gas shutoff valve is supplied on CE models. The appliance must be isolated from the gas supply piping system by closing its individual manual shut- off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½psi (3.45 kPa).
4. LIGHTING INSTRUCTIONS HHP and HHPS Gas Open Burner Ranges are furnished with either a pilot safety valve or a standing pilot (not available in the European Community). Please follow the instructions for your unit. Pilot Operation Flame Failure Gas Valve: Operation of the gas valve pilot: 1.
Main burner air supply: For efficient burner operation, a proper balance of gas volume and primary air supply must be maintained which will result in complete combustion. Insufficient air supply results in a yellow streaming flame. Primary air supply is controlled by an air shutter on the front of the burner. Loosen the screws on the front of the burner, and adjust the air shutter to just eliminate the yellow tips of the burner flame.
6. CONVERSION Instructions are for conversion from Natural Gas to Propane (L.P.) on all models TSHHP and TSHHPS. The conversion should be done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP (propane) are provided in a bag tied to the valve on the front panel.
APW WYOTT EQUIPMENT LIMITED WARRANTY APW Wyott Foodservice Equipment Company warrants it's equipment against defects in materials and workmanship, subject to the following conditions: This warranty applies to the original owner only and is not assignable. Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of APW Wyott such product will be repaired or replaced by APW Wyott or its Authorized Service Agency.