Download Print this page

Disposal Of Batteries; Technical Data; Troubleshooting - Gira 5122 00 Operating Instructions

Rf remote control

Advertisement

RF remote control
Press the Prog button.
The status LED (1) lights up red.
Load the physical address and domain address into the device.
The status LED goes out.
Write the physical address and domain address on the inner side of the battery compart-
ment lid.
Load the application software into the device.
Before updating the system software or changing the application software, replace a bat-
tery with a new, unused battery.
6

Disposal of batteries

Remove empty batteries immediately and dispose of in an environmentally friendly
manner. Do not throw batteries into household waste. Consult your local authorities
about environmentally friendly disposal. According to statutory provisions, the end
consumer is obligated to return used batteries.
7

Technical data

Rated voltage
Battery type
Ambient temperature
Degree of protection
Dimensions L×W×H
Order no. 5122 00
Order no. 5124 00
KNX
KNX medium
Commissioning mode
Radio frequency
Transmission capacity
Transmitting range in free field
Receiver category
8

Troubleshooting

After a button has been pressed, the status LED flashes red slowly for 3 seconds.
Cause: Battery in the hand-held transmitter is almost empty.
Changing the battery (see chapter Commissioning – Changing the battery).
32590832
10867223
Figure 4: Button Prog
20.12.2019
DC 3 V
1×Lithium CR 2450N
-5 ... +45 °C
IP20
55×40.5×15 mm
93×53×15.5 mm
RF1.R
S-mode
868.0 ... 868.6 MHz
max. 20 mW
typ. 100 m
2