GURTNER ICON 1 Installation And Operating Instructions Manual

Advertisement

CONTROL ICON 1 &
ICON 2
Installation and operating instructions
rot

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICON 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for GURTNER ICON 1

  • Page 1 CONTROL ICON 1 & ICON 2 Installation and operating instructions 
...
  • Page 2 General safety instructions Intended Use • The controls icon 1 and icon 2 are designed for the infrared heater InfraROTmed and are used exclusively for controlling suitable full-spectrum emitters/red light heaters (e.g. InfraROTmed). • The controllers are only designed for the specified total power and the respective output connection value.
  • Page 3 Installation Installation of the power unit The power section is mounted using screws in a temperature- and moisture-protected area with a maximum ambient temperature of 35°C (e.g. on the cabin roof, under the bench or behind the rear wall). The power unit emits heat during the dimming process, so ensure adequate ventilation. The power unit must not be covered.
  • Page 4 Also make sure that your supply line is sufficiently protected for the connected load: 10A at icon 1 touch; 13A with icon 2 Touch After the check, the controller can be connected directly to the socket using a protective...
  • Page 5 Icons 1 and 2 are identical in use, they only differ in the number of buttons and the display for lamp control. Display for infrared heater 1 (icon 1) or 1-2 (icon 2) and their set power value Timer display: remaining time until shutdown Buttons in the first row 1:
...
  • Page 6 The course of a session in an infrared cabin However, everyone reacts differently to heat, so everyone should find their own comfort zone. Showering and drying off make sweating easier Before the session, drink mainly water, tea and unsweetened juices Use a towel or something similar to sit on Duration of use approx.
  • Page 7 General warnings on the use of infrared heaters and infrared cabins: If you suffer from an illness or are not sure whether the use of an infrared cabin or an infrared heater is suitable for you, please consult your doctor. For example, you may not use the infrared cabin/infrared heater if you have open wounds, after operations, if you have eye diseases, if you have severe sunburn and if you are under the influence of alcohol.
  • Page 8 50 Hz mains: TN-S P+N+PE (according to DIN VDE 0100-540:2007-06 (Pt 543.4.3)) Power: maximum overall performance icon 1 Touch: 1,5 kW; 1 channel max 10A/230V maximum overall performance icon 2 Touch: 2,8 kW; 2 channels max 6A each, overall max. 13A Degree of protection housing: IP20 (EN 60529) cooling: passive, maximum ambient temperature 45°C...

This manual is also suitable for:

Icon 2

Table of Contents