Aristel AN1801 Manual

Lte - 4g smoke detector

Advertisement

Quick Links

AN1801 LTE - 4G Smoke Detector
AN1801 
LTE - 4G Communicator 
with Smoke Detector 
Accessory for Smoke Alarm  
Aristel Networks.
E1.2 1/8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AN1801 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aristel AN1801

  • Page 1 AN1801 LTE - 4G Smoke Detector AN1801  LTE - 4G Communicator  with Smoke Detector  Accessory for Smoke Alarm   Aristel Networks. E1.2 1/8...
  • Page 2 AN1801 LTE - 4G Smoke Detector Important Safety Instructions  This user manual contains important guidelines for the installation and usage of the LTE device in  combination with the SD360 smoke alarm.  Please read the manual thoroughly before you start using the device. It contains vital information  on unit operation and installation. If you are installing this device the manual must be given to the  householder.  The user must regularly check the proper functioning of the device. The manufacturer cannot be  held liable for any damage or loss caused by any incorrect use or incorrect operation of the  device.  In case of damage caused by disregarding the guidelines, the warranty becomes invalid.  Safety guidelines  ‧ The operation temperature range is from 0°C to 49°C (32°F to 120°F). ‧ The device is intended for use in dry and clean places with a residential function. ‧ Protect the device from moisture, heat and water splashing. ‧ The guidelines for the battery usage must be regarded. ‧ Do not expose the device to strong vibrations. ‧ Do not let it fall from height. ‧ Do not use in an environment where any inflammable gases, vapors or dust are present or could be present. ‧ Repair of the device may only be carried out by people, trained for repair. ‧ If the device must be repaired, only original replacement components may be used. Use in accordance with the regulations  The purpose of this device in accordance with the regulations is sending SMS text messages and  making telephone calls after an alarm situation. Other uses are not permitted and may annul the ...
  • Page 3 2.4 Close the cover ........................6  2.5 Insert the battery of SD360 ....................6  2.6 Mount the AN1801 to the ceiling .................... 6  2.7 Set up by SMS and program at least one telephone number and perform a test ....7 ...
  • Page 4 AN1801 LTE - 4G Smoke Detector 1. GENERAL DESCRIPTION The 4G communicator AN1801 is a battery operated  4G module used to send out an alarm after  the input is triggered by the smoke detector SD360.  The 4G Smoke Detector, AN1801 is a combination of the AN1801 Radio module connected with a  SD360 smoke alarm.    The default settings for standard use are:  ‐    In case the output alarm of SD360 smoke detector is activated, the 4G communicator sends  an alarm SMS text message and calls the phone numbers as programmed by the user.  ‐    In case the batteries need to be replaced, the 4G communicator sends a  `battery low'  SMS text message to the phone numbers as programmed by the user.  Please refer to the manual of the SD360 smoke alarm for installation instructions and the  description of the behavior of the smoke alarm.  2. GETTING STARTED To get started with the AN1801 at least the following steps need to be taken in following order: 1. Open the cover 2. Insert a SIM card (without PIN code) 3. Insert the battery on AN1801 4. Close the cover 5.
  • Page 5 AN1801 LTE - 4G Smoke Detector 2.1 Open the cover  Push the bottoms of 3 buckles and open the cover  Fig 1 2.2 Insert a SIM card  Push the black cover outward slightly to open the holder. Before installing the SIM card should  have PIN code removed. Insert a SIM card into the module.  (A PIN code can be changed or removed by putting the SIM card in to any mobile phone and  entering the 'security' menu).  Note: Make sure the SIM card is inserted before the batteries are inserted. In case of a SIM card  change, please first remove the batteries (and remove any other external power supply).    2.3 Insert the battery  Insert the batteries (CR123A) in the module. Use the + / ‐ indication for the correct placement.  SIM card battery Fig 2 E1.2 5/8...
  • Page 6 AN1801 LTE - 4G Smoke Detector 2.4 Close the cover (Fig 3)  2.5 Insert the battery of SD360  Insert the batteries in the SD360. Use the + / - indication for the correct placement. Fig 3 Fig 4 2.6 Mount the AN1801 to the ceiling  2.6.1    Mount the Base in which the AN1801 is fixed to the desired place to the ceiling, and screws  which can be found inside the AN1801 box. Please refer to the manual of the SD360 smoke alarm  for the ideal location and installation instructions.  2.6.2  Bring the AN1801 and the base module to each other at the correct position and turn the  detector gently clockwise until it is closed and locked.    Fig 5 Fig 6 Aristel Networks .
  • Page 7 AN1801 LTE - 4G Smoke Detector 2.7 Set up by SMS and program at least one telephone number and perform a test  2.7.1 Booting up the device  Press the test button five times to wake up the  4G module to boot up and enters standby  mode.  Note: Wake up 4G modules before performing any SMS setup Press the test button 5 times and testing Fig 7 2.7.2 Setting SMS command  You can program many different function codes in one text message with SMS command format.  *12*1234 # [function Code 1] # [function Code 2] # [function Code 3] #..  (Please refer the page 8: 3. SMS Command & 4. Function Codes)  Example: Store the numbers, maximum 3 numbers.  1. Send the text SMS to the number of device. 2. The format of text SMS is: *12*1234#11[ number 1 ]#12[ number 2 ]#13[ number 3 ]# 3. When the setting is finished, the sender will receive the reply as below. 11[ number 1 ]#12[ number 2 ]#13[ number 3 ]#OK 2.7.3 Test Smoke Alarm  Press and hold the button for around 4 seconds until the horn sounds during standby, AN1801 ...
  • Page 8 AN1801 LTE - 4G Smoke Detector 2.8 LED Indicators Status  Green LED  Blue LED  Module Green LED (Hide on PCB)  Booting up  0.5s ON / 1.5s OFF  OFF  Unregistered the network :  Standby  OFF  0.5s ON / 1.5sOFF  0.5s ON / 0.5s OFF  Notification  OFF  0.1s ON / 0.1s OFF  Registered the network :    0.3s ON / 2.7s OFF  no number  0.5s ON / 0.5s OFF  0.5s OFF / 0.5s ON  Sleep  OFF  OFF  OFF  3. SMS Command Feature  SMS Command  Default SMS content  NOTE: ...

Table of Contents