Installation Instructions
Dimensional
Specifications
Electrical
Specifications
Before installing the pump, remember the following:
1. Vacuum pump can be installed horizontally (either right-side
up
or upside down
A
2. The pump can be mounted from 2 to 15 feet from the vacuum
tank. The maximum distance is 15 feet.
3. Install vacuum pump at same level or lower than vacuum tank
outlet. Do not install pump higher than the vacuum tank outlet.
4. The maximum head pressure on the discharge of the pump must
not exceed 6 feet.
Note: Two-toilet systems require a vacuum pump and vacuum tank for each toilet.
It provides the benefit of a totally redundant operating toilet in case of failure in one
toilet. Two pumps greatly reduce hose runs and system complexity.
Installing the pump:
1. Make sure the vacuum pump is properly located before proceeding. Place the vacuum pump on the surface
to be mounted. Position as needed. Using a center punch, mark the four slotted holes in the pump feet.
Remove pump.
2. Using a 3/16-inch drill bit, drill the four mounting holes. Use a #14 wood screw to secure pump.
3. The flow direction is indicated on the pump body.
Stainless steel wall mounting bracket is available as optional accessory – P/N 341505.
Wiring the pump:
Wire the S-series pump as shown in the wiring diagram. Use multistranded copper wire. Proper fuse or circuit
breaker size is extremely important for pump and wire protection (see chart above). Overfusing this pump will
result in warranty invalidation.
Model
Volts (DC)
SW12
12
SW24
24
), or vertically with inlet at bottom
B
Avg. Amp Draw
GPH
6
230
3
230
.
C
Electrical schematic also shows installation of optional "night
switch".
Dometic Corporation, Sanitation Division
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611 USA
1-800-321-9886 • Fax: 330-496-3097
Fuse/Breaker
Wire Size
10 amps
12-14 ga.
5 amps
14-16 ga.
B
A
www.Dometic.com
Weight
8 lbs.
8 lbs.
C

Advertisement

loading

Summary of Contents for Dometic SW12

  • Page 1 S Vacuum Pump with W Motor Dometic Corporation, Sanitation Division 13128 State Rt. 226, P.O. Box 38 Installation Instructions Big Prairie, OH 44611 USA 1-800-321-9886 • Fax: 330-496-3097 www.Dometic.com Dimensional Specifications Electrical Model Volts (DC) Avg. Amp Draw Fuse/Breaker Wire Size...