  • Page 1 onair 1600 Air Purifier user manual 1-20 original manual translation...
  • Page 2 Dear customer: Thank you very much for placing your trust in a quality product from TEINNOVA. This product is manufactured using modern production processes and extensive quality assurance measures. We try to do everything possible to ensure that you are satisfied with this product and can work with it without any problems.
  • Page 3 index symbology 5-20 safety warnings 6-20 conditions of use 7-20 know your machine 8-20 accessories and related equipment 9-20 operating instructions 10-20 transport 12-20 maintenance and care 13-20 waste management 17-20 onair 1600 Air Purifier 3-20...
  • Page 4 index technical specifications 18-20 guarantee conditions 19-20 declaration of conformity 20-20 onair 1600 Air Purifier 4-20...
  • Page 5 symbology All the existing graphic symbols in this manual as well as those indicated on the equipment itself are explained in this section, it is important to read with special attention the text related to this symbology as it is related to personal and equipment safety.
  • Page 6: Safety Warnings

    Persons operating ONAIR 1600 equipment must be sufficiently trained. Do not open the control box of your ONAIR 1600 extraction unit. In the event of a fault, please contact TEINNOVA’s Technical Assistance Service on +34 941 44 50 56. onair 1600...
  • Page 7: Conditions Of Use

    conditions of use The ONAIR 1600 machine has been designed and manufactured for air purification in any enclosed room. It has four stages of filtration PREFILTER G4 - BAG FILTER M5 - ABSOLUTE HEPA FILTER H13 - ACTIVE CARBON FILTER and a UV-C lamp. This equipment complies with the requirements set out in the UNE 100012:2005 STANDARD “Hygiene in air conditioning systems”.
  • Page 8: Know Your Machine

    know your machine Components: 1- Top cover with grille 9- Display 2- Active carbon filter 10- Hour counter 3- Carbon filter support 11- ON/OFF switch 4- Tightening lock for top cover 12- HEPA absolute filter H13 5- UV-C lamp for purification 13- Bag filter M5 6- Wheel 14- Pre-filter G4...
  • Page 9: Optional Accessories

    accessories and related equipment Optional accessories: Pre-filter G4 Special filter for efficient and quality work with your ONAIR 1600 (10 pieces). Cod. AC3101305 Bag filter M5 Special filter for efficient and quality work with your ONAIR 1600. Cod. AC3101306 HEPA absolute filter H13 Special filter for efficient and quality work with your ONAIR 1600.
  • Page 10 operating instructions Steps for a correct installation of ifoam: Fitting your ONAIR 1600: Place your ONAIR 1600 on a smooth and stable surface. Place the machine close to a mains socket. Once the machine is in an optimal position for the work to be carried out, lock the brakes on the front wheels so that the machine remains stable.
  • Page 11 operating instructions Suction quantity control of your ONAIR 1600: The suction quantity of your ONAIR 1600 can be adjusted by means of the potentiometer. On the lower display you will see the amount of air being suc- ked in and it will vary according to the intensity applied to the potentiometer.
  • Page 12 transport The machine is designed to be transported in a small van. The machine may only be transported in its working position (upright). The machine shall be securely fastened to the vehicle chassis and the brakes on the front wheels shall be applied to prevent knocks and slipping during transport.
  • Page 13: Maintenance And Care

    maintenance and care Keep the machine as clean as possible. Keep the equipment in a place protected from the weather. Replace the UV-C lamp after prolonged use. Lifetime is 9000 hours. Replace or clean filters after prolonged use. It is recommended to change filters every 4000 operating hours or after one year.
  • Page 14: Maintenance Operations

    maintenance and care Maintenance operations: Change of filters and UV-C lamp: If the filters are saturated or already need to be replaced, proceed as follows, always with the machine switched off and unplugged. Switch off the machine by pressing the ON/OFF switch as shown in the figure.
  • Page 15 maintenance and care Open the front lock and lift the cover to remove the filters and change the UV-C lamp. Remove the filters from their compartment as shown in the figure. If cleaning is not sufficient, they must be replaced with new ones.
  • Page 16: Spare Parts

    Spare parts: TEINNOVA has spare parts for all parts of the machine as well as consumables for all the maintenance tasks indicated in this manual. Should you require any parts or consumables, please contact TEINNOVA Customer Service on +34 941 44 50 56.
  • Page 17: Waste Management

    waste management The materials used in the packaging are recyclable. Do not dispose of the packaging in household waste and hand it in at official collection points for recycling. Do not throw electrical appliances in the trash! We recommend that electrical tools and accessories are subjected to an environmentally friendly recycling process.
  • Page 18: Technical Specifications

    technical specifications Features ONAIR 1600 220V / 50Hz 110V / 60Hz Maximum flow rate 2000 m /h // 1471,44 cfm Maximum depression 2500 Pa // 0,36 psi Operating point 1600 m /h a 1800 Pa 941,7 cfm a 0,26 psi Clean zone at 1 air renewal/hour 1600m / 640m...
  • Page 19: Guarantee Conditions

    1). TECAI INNOVA S.L. C/ Las Balsas 16-B, Pol. Ind. Cantabria. 26009 LOGROÑO (La Rioja), Spain. TEINNOVA reserves the right to make changes to the equipment without giving prior notice. onair 1600 Air Purifier 19-20...
  • Page 20 Telephone number: +34 941 44 50 56 Fax: +34 941 25 24 71 Web: www.teinnova.net TECAI INNOVA, SL, under its sole responsibility, certifies that the machine model described above complies with all the essential requirements of the following directives: Machinery directive 2006/42/CE Directive 2014/30/EU on electromagnetic compatibility and its amendments.