Read carefully before using the meter!
Measuring range: 5% – 40%
Display: 1% increments
Precision: 5 20% = +/ 2%, 21 40% = +/ 1%
Temperature range for use: 0°C – 40°C
Dimensions: 129 x 63 x 32mm
Weight: 116 g with battery
Open the battery compartment cover (6) in the direction of the arrow and remove the protective paper between the contacts and the battery (8). Connect the contacts to the battery and put the battery compartment cover (6) back on. The device is now ready to use.
Push the cap (5) tab where it says (UP) and take off the cap. Press the ON/OFF switch (1).
Press the two test pins (7) into the wood surface with slight pressure. The moisture content of the wood will be shown on the display (3) in percent.
The reading can be stored until the next measurement by pressing the memory button (2). Pressing the button again deletes the reading.
To get a correct reading of the inside of the wood, split it and measure the interior surface. Take readings at 3 places to get an average. The meter can be used on all wood surfaces.
After measurement is completed switch the meter off and put the cap (5) back on!
Readings for firewood:
5-15 % = Very good for heating
16-20 % = Can be used for heating with some limitations
21-40 % = Not suitable. Needs further drying.
The test pins (7) are very sharp. Risk of injury! Keep the meter away from children! Never direct the test pins at people or animals!
Note:
If the meter is not going to be used for an extended period, take the battery out. When the battery symbol (4) appears, the battery (8) needs to be replaced by a new 9 volt battery.
Do not put batteries in household waste!
Per European Guideline 2002/96/EG on old electrical and electronic devices, 2006/66/EG on batteries and old batteries, and the national legislation based on them, old electric tools and batteries must be collected separately for environmentally appropriate recycling.
Protect the meter from moisture, and store it in a dry place. Wipe off any dirt with a damp cloth.
If necessary, remove the protective film on the display (3).
If necessary, replace the test pins (9). To do so, use a suitable tool to remove the old pins by turning them counterclockwise. Replacement test pins are available under order number 988 050 517.
DOLMAR GmbH