4TX + 1MMFX Unmanaged Ethernet Switch
Trend supply the following Ethernet switch:
EDS-305-M-SC
:Unmanaged Ethernet Switch with 4 off 10/100BaseT(X) ports, 1 multi mode 100 BaseFX
port, SC connector, 0 to 60 °C
Other options referred to in the installation instructions, and other accessories are not supplied.
The attached installation instructions are supplied by Moxa Networking Company Ltd:
P/No: 18020030003 edition 4, 25/09/04
For additional information see ED-305 data sheet TA200836
EDS-305 Installation Instructions TG200839 Issue 1/A 09/12/04
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EDS-305 and is the answer not in the manual?

Questions and answers

Summary of Contents for TREND EDS-305

  • Page 1 Other options referred to in the installation instructions, and other accessories are not supplied. The attached installation instructions are supplied by Moxa Networking Company Ltd: P/No: 18020030003 edition 4, 25/09/04 For additional information see ED-305 data sheet TA200836 EDS-305 Installation Instructions TG200839 Issue 1/A 09/12/04...
  • Page 2 Installation Instructions This page is left intentionally blank Trend Control Systems Ltd reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes.
  • Page 3: Moxa Etherdevice Switch

    MOXA EtherDevice Switch EDS-308/305 Hardware Installation Guide Fourth Edition, September 2004 Moxa Networking Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 www.moxa.com support@moxanet.tw (Worldwide) support@moxa.com (The Americas) P/N: 18020030003...
  • Page 4: Package Checklist

    Overview The MOXA EtherDevice™ Smart Switches, EDS-308/305 Series, are 8- and 5- port Ethernet Switches that provide an economical solution for your Ethernet connections, and the built-in smart alarm function helps system maintainers monitor the health of your Ethernet network. These products have a wide operating temperature range, from -40 to 75°C, and are designed to withstand a high degree of vibration and shock.
  • Page 5 Panel Layout of EDS-305 Series EDS-305 EDS-305-M-SC EDS-305-S-SC Front Panel View Front Panel View Front Panel View Top Panel View Grounding screw Terminal block for power input P1/P2 and relay output PWR2 Heat dissipation orifices FAULT PWR1 DIP switches V1 V2 INPUTS: 24 VDC...
  • Page 6 Panel Layout of EDS-308 Series EDS-308 EDS-308-M-SC EDS-308-SS-SC Front Panel View Front Panel View Front Panel View Top Panel View NOTE: The appearance of EDS-308-S-SC is identical to EDS-308-M-SC, and the appearance of EDS-308-MM-SC is identical to EDS-308-SS-SC. PWR2 FAULT Grounding screw PWR1 V1 V2 INPUTS: 24 VDC...
  • Page 7: Mounting Dimensions (Unit = Mm)

    Mounting Dimensions (unit = mm) Side View 30.00 54.00 9.50 135.00 Front View Back View Panel Mount Kit 15.10 13.90 13.90 13.10 25.40 18.20 9.75 3.50 6.00 3.50 6.00 30.50 7.75 7.75 135.00 30.50 10.65 10.65 — 4 —...
  • Page 8: Din-Rail Mounting

    DIN-Rail Mounting The aluminum DIN-Rail attachment plate should already be fixed to the back panel of EDS when you take it out of the box. If you need to reattach the DIN-Rail attachment plate to EDS, make sure the stiff metal spring is situated towards the top, as shown in the figures below. STEP 1: STEP 2: Insert the top of the DIN-Rail into the...
  • Page 9: Wall Mounting (Optional)

    Wall Mounting (OPTIONAL) For some applications, you will find it convenient to mount MOXA EtherDevice Switch on the wall, as illustrated below. STEP 1: Remove the aluminum DIN-Rail attachment plate from MOXA EtherDevice Switch’s rear panel, and then attach the wall mount plates, as shown in the diagram below. plate ⇒...
  • Page 10: Wiring Requirements

    Wiring Requirements WARNING Do not disconnect modules or wires unless the power supply has been switched off or the area is known to be non-hazardous. The devices may only be connected to the supply voltage shown on the type plate. The devices are designed for operation with a safety extra-low voltage.
  • Page 11: Wiring The Alarm Contact

    Grounding MOXA EtherDevice Switch Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices. This product is intended to be mounted to a well-grounded mounting surface, such as a metal ATTENTION panel.
  • Page 12: Wiring The Redundant Power Inputs

    Wiring the Redundant Power Inputs The top two contacts and the bottom two contacts of the 6-contact terminal block connector on EDS’s top panel are used for EDS’s two DC inputs. Top and front views of one of the terminal block connectors are shown here.
  • Page 13: Communication Connections

    EDS-308 models have 6, 7, or 8 10/100BaseT(X) Ethernet ports, and 2, 1, or 0 (zero) 100BaseFX (SC-type connector) fiber ports. EDS-305 models have 4 or 5 10/100BaseT(X) Ethernet ports, and 1 or 0 (zero) 100 BaseFX (SC-type connector) fiber ports.
  • Page 14: 100Basefx Ethernet Port Connection

    100BaseFX Ethernet Port Connection The concept behind the SC port and cable is quite straightforward. Suppose you are connecting devices I and II. Contrary to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used transmit data from device II to device I, for full-duplex transmission.
  • Page 15: Dip Switch Settings

    DIP Switch Settings EDS-308 Series DIP Switches EDS-305 Series DIP Switches ON: Enables the corresponding PORT Alarm. If the port’s link fails, the relay will form an open circuit and the fault LED will light up. Off: Disables the corresponding PORT Alarm. The relay will form a closed circuit and the Fault LED will never light up.
  • Page 16: Auto Mdi/Mdi-X Connection

    Auto MDI/MDI-X Connection The Auto MDI/MDI-X function allows users to connect MOXA EtherDevice Switch’s 10/100BaseTX ports to any kind of Ethernet device, without needing to pay attention to the type of Ethernet cable being used for the connection. This means that you can use either a straight-through cable or cross-over cable to connect EDS to Ethernet devices.
  • Page 17: Auto-Negotiation And Speed Sensing

    automatically keeps up with new node locations. An address-aging algorithm causes the least-used addresses to be deleted in favor of newer, more frequently used addresses. To reset the address buffer, power down the unit and then power it back up. Auto-Negotiation and Speed Sensing All of MOXA EtherDevice Switch’s RJ45 Ethernet ports independently support auto-negotiation for speeds in the 10BaseT and 100BaseTX modes, with operation according to the IEEE 802.3u...
  • Page 18 Input Current @ 24VDC 0.25 A (EDS-305, EDS-305-M, EDS-305-S, EDS-308) 0.35 A (EDS-308-M, EDS-308-S, EDS-308-MM, EDS-308-SS) Connection Removable Terminal Block Overload Current Protection 1.1 A (EDS-305, EDS-305-M, EDS-305-S, EDS-308) 1.6 A (EDS-308-M, EDS-308-S, EDS-308-MM, EDS-308-SS) Reverse Polarity Protection Present Mechanical Casing...
  • Page 19: Moxa Internet Services

    MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa has set up on-line support services to provide technical support, driver updates, product information, and user’s manual updates. E-mail for technical support: support@moxanet.com (Worldwide)