Download Print this page

Sealey SAC42755B Manual

Compressors 270ltr vertical belt drive 5.5hp/7.5hp 3ph 2-stage

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! ElEctrical installation of comprEssor to a 3-phasE 415Volt supply must only bE
carriEd out by a qualifiEd ElEctrician.
make sure the power supply cable is correctly connected to the earth. it is the user's responsibility to read, understand and
comply with the following:
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads,
plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of
appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board.
you must also read and understand the following instructions concerning electrical safety.
The Electricity at Work act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
The health & safety at Work act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance and
the safety of the appliance operator. if in any doubt about electrical safety, contact a qualified electrician.
Ensure insulation on all cables and the product itself is safe before connecting to mains power supply.
Ensure that cables are always protected against short circuit and overload.
Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage, especially power connections, to
ensure that none are loose.
important: Ensure the voltage marked on the product is the same as the electrical power supply to be used. A three phase plug must
be fitted to this machine.
DO NOT pull the powered appliance by the power cable.
8
DO NOT pull power plugs from sockets by the power cable.
8
DO NOT use worn or damage leads, plugs or connections. Replace immediately or have repaired by a qualified electrician.
8
this product must be fitted with a 3-phase plug according to the diagram, and will require a minimum of 16amps per phase,
(preferably 32amp) electrical supply. you must contact a qualified electrician to ensure an appropriately fused supply is
available.
Connect GREEN/YELLOW wire to earth
Connect the live wires to live 1, 2 and 3. Check for the correct direction of rotation (see arrow on belt cage) to confirm correct
wiring of 3-phase plug when you first run the compressor.
When completed, check that there are no bare wires, that all wires have been connected
correctly, that the cable external insulation extends beyond the cable restraint and
that the restraint is tight.
1.2.
GENERAL SAFETY
Familiarise yourself with the application and limitations of the compressor.
9
Ensure that the compressor is in good condition before use. If in any doubt DO NOT use the unit and
9
contact an electrician/service agent.
IMPORTANT! The compressor must be installed and commissioned by qualified personnel.
WARNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with,
or attempt to adjust, pressure switch or safety valve.
Before moving or maintaining the compressor ensure it is unplugged from the mains supply and that
9
the air tank pressure has been vented.
Only use recommended attachments and parts. To use unauthorised items may be dangerous and
9
will invalidate your warranty.
© Jack Sealey Limited
COMPRESSORS 270LTR VERTICAL BELT DRIVE
5.5HP/7.5HP 3PH 2-STAGE
SACV42755B, SACV52775B
mODEL NO'S:
Refer to
instruction
manual
Warning! Hot
surface
(E) terminal.
Original Language Version
Wear eye
Wear ear
Ensure oil level
protection
protection
before first use
Warning!
DO NOT
Automatic
operate with
start up
enclosure
cock before an
displaced
SAC42755B, SAC52775B | Issue:2 (H3F) 26/03/19
Warning!
is correct
electricity
DO NOT
Indoor use only
open the air
air hose is
attached

Advertisement

loading

Summary of Contents for Sealey SAC42755B

  • Page 1 SACV42755B, SACV52775B mODEL NO’S: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    When fully installed, start the compressor and ensure that everything is in good working order before operational use. 4.9. Check the direction of rotation (see arrow on motor) to confirm correct wiring of 3-phase plug. Re-check oil levels. Original Language Version SAC42755B, SAC52775B | Issue:2 (H3F) 26/03/19 © Jack Sealey Limited...
  • Page 3: Operation

    (Wear eye protection and DO NOT direct air towards the body or hands). DO NOT operate the compressor without the filter as foreign bodies or dust could seriously damage the pump. Replace the filter element. b) Check for oil leaks. SAC42755B, SAC52775B | Issue:2 (H3F) 26/03/19 © Jack Sealey Limited Original Language Version...
  • Page 4: Recommended Oils

    Example: Body filler dust or paint over-spray will clog the pump intake filter and may cause internal damage to pump/motor components. Please note that any parts damaged by any type of contamination will not be covered by warranty. © Jack Sealey Limited Original Language Version SAC42755B, SAC52775B | Issue:2 (H3F) 26/03/19...
  • Page 5: Troubleshooting

    Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...

This manual is also suitable for: