Lubrication Of The Gas Taps - CDA HVG 93 Series Manual For Installation, Use And Maintenance

Gas on glass cooktop
Table of Contents

Advertisement

20
Table for the Choice of the Injectors
Burners
Auxiliary (A)
Semi-Rapid (SR)
Rapid (R)
Triple Ring (TR)

Lubrication of the Gas Taps

The operations must be executed by a qualified technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of the applian-
ce must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.
Nominal
Reduced
Power
Power
kW
kW
1,00
0,30
1,75
0,45
3,00
0,75
3,50
1,50
GB
G30 - 28-30 mbar
G20 - 20 mbar
G31 - 37 mbar
Ø Injector
1/100 mm
50
65
85
95
Cat: II 2H3+
Ø Injector
1/100 mm
72 (X)
97 (Z)
115 (Y)
135 (T)