Download Print this page
Kaisai XK60 Owner's Manual

Kaisai XK60 Owner's Manual

Wired controller

Advertisement

Quick Links

OWNER"S MANUAL
XK60 WIRED CONTROLLER

Advertisement

loading

Summary of Contents for Kaisai XK60

  • Page 1 OWNER”S MANUAL XK60 WIRED CONTROLLER...
  • Page 2 This wired controller is applicable to various kinds of air conditioners, while some specific functions unavailable to the duct type air conditioners will not be covered in this manual. Before operating the air conditioner, please read this manual carefully and keep it properly for future reference. kaisai.com...
  • Page 3 Wired Controler XK60 1 Introduction to the Wired Controller Fig.1 Appearance of the Wired Controller 1.1 Appearance and LCD Icons Fig.2 Appearance of the LCD kaisai.com...
  • Page 4 Wired Controler XK60 1.2 Introduction to the LCD Icons Table 1 Icons Introduction Left and right swing function Up and down swing function Air exchange function Sleep function Auto mode COOL mode DRY mode FAN mode HEAT mode Health function...
  • Page 5 Wired Controler XK60 Electric heater Blow function Defrosting function Filter cleaning Timer Setting Keycard control / Detected status sensed by human body Quiet function Lock function 2 Press Buttons 2.1 Buttons Fig.3 Press Buttons 2.2 Instruction to the Function of Press Buttons...
  • Page 6 Wired Controler XK60 Select fan speed from high, mid-high, middle, mid-low, low and auto levels. Mode Selection of the COOL, HEAT, FAN, Auto or DRY mode. Switchover among these functions of Function SWING/AIR/SLEEP/HEALTH/I-DEMAND/VACATION/TURBO/SAVE/E-H EATER/BLOW/QUIET Timer Timer setting On/Off Turn on/off indoor unit Press Mode and ▲...
  • Page 7 Wired Controler XK60 3.2 Mode Setting Under the ON state of the unit, press the Mode button to switch the operation modes as the sequence shown in Fig.6: Fig.6 3.3 Temperature Setting Press ▲ or ▼button to increase or decrease setting temperature under on-state of the unit.
  • Page 8 Wired Controler XK60 3.4 Fan Speed Setting Press Fan button, fan speed of indoor unit will change as the sequence shown in Fig.8: Fig.8 Fan Speed Setting 3.5 Right and Left Swing Under the ON state of unit, press the Function button to select the “Right and Left Swing”...
  • Page 9 Wired Controler XK60 Fig.9 Right and Left Swing Setting 3.6 Up and Down Swing Under the ON state of unit, press the Function button to select the "Up and Down Swing" function option and then press the Enter/Cancel to activate it.
  • Page 10 Wired Controler XK60 Fig.10 Up and Down Swing Setting 3.7 Timer Setting Timer “On” Setting: It is intended to set when to start the unit. When the unit is OFF, press the Timer button, with xx. Hour displayed and ON blinking, then press ▲/▼ to adjust the timer, after that, press the Timer button again to make a confirmation.
  • Page 11 Wired Controler XK60 Timer Setting under the ON state of the Unit is as shown in Fig.11: Fig.11 Timer Setting under the ON state of the Unit Timer range: 0.5-24hr. Every press of the ▲ or ▼ button will make the setting time increased or decreased by 0.5hr.If press either of them continuously, the setting time...
  • Page 12 Wired Controler XK60 controller. 1――The unit continuously runs for 60min, and fresh air valve runs for 6 min. 2――The unit continuously runs for 60min, and fresh air valve runs for 12 min. 3――The unit continuously runs for 60min, and fresh air valve runs for 18 min.
  • Page 13 Wired Controler XK60 3.9 Sleep Setting Sleep on: Press the Function button under the ON state of the unit to select the “Sleep” function option and then press the Enter/Cancel button to activate it. Sleep off: When the Sleep function is activated, press the Function button to select the Sleep function option and then press the Enter/Cancel button to deactivate this function.
  • Page 14 Wired Controler XK60 Fig.14 Sleep Curve under the COOL Mode Under the Heat mode, the Sleep function is ON, the setting temperature range can be 16°C, 17~20°C, 21~27°C or 28~30°C. Each of them has a different curve as shown in Fig.15.
  • Page 15 Wired Controler XK60 3.10 Health Setting Under unit on status, press “Function” button to select health function with “Health” icon flashing. Press “Enter/Cancel” button to activate health function. When health is on, press “Function” button to set function, with “health” icon flashing.
  • Page 16 Wired Controler XK60 icon flashing. Then press the “Enter/Cancel” button to cancel I-Demand function. How to set I-Demand function is shown in the Fig.17: Fig.17 I-Demand Setting Note: The I-Demand function can be cancelled by mode switch and unit ON/OFF.
  • Page 17 Wired Controler XK60 “Enter/Cancel” button to cancel Vacation function with no icon flashing. How to set vacation function is shown in the Fig.18: Fig.18 Vacation Setting Note: The vacation function can be only set under heating mode. ①. The turbo function will be cancelled when the vacation function is set.
  • Page 18 Wired Controler XK60 heating so that room temperature can quickly approach the setting temperature. In the COOL or HEAT mode, press the Function button to select the "Turbo" function option and then press the Enter/Cancel button to activate it. When the "Turbo" function is activated, it can be deactivated by firstly pressing the Functionbutton to select the "Turbo"...
  • Page 19 Wired Controler XK60 (1) Method 1 for setting SAVE function: Energy Saving Setting for Cooling When the unit runs under the COOL or DRY mode, press the Function button to select the “SAVE” function option, with “SAVE” flashing, and then press ▲ or ▼ to adjust the lower limit, after that, press the Enter/Cancel button to activate this function.
  • Page 20 Wired Controler XK60 During the “SAVE” setting, if the Function button is pressed down or there is ②. not any operation within 5s after the last button operation, the system will quit the “SAVE” setting with the current setting data not saved.
  • Page 21 Wired Controler XK60 Fig.21 SE setting (2) Notes: If turn on SE function under AUTO mode, it will skip to related mode ①. compulsively and then the SE function will be turned on; Under SE function setting status, if there’s no operation within 20s after the ②.
  • Page 22 Wired Controler XK60 3.15 E-HEATER Setting E-HEATER: in the HEAT mode, “E-HEATER” function is allowed to be activated to improve the heating efficiency. Generally, it will be activated automatically as the unit goes into the HEAT mode through any button operations.
  • Page 23 Wired Controler XK60 3.16 Blow Function Setting BLOW function: After the unit is turned off, water in evaporator of indoor unit will be automatically evaporated to avoid mildew. Activation of the “Blow” Function: in the COOL or DRY mode, press the Function button to select the “Blow”...
  • Page 24 Wired Controler XK60 to adjust pollution level and press “Enter/Cancel” button to activate Filter function. When the Filter function is set, press “Function” button to set with “Filter” icon flashing. Press “▲” and “▼” to adjust till “00” is shown on the timer area. Then press “Enter/Cancel”...
  • Page 25 Wired Controler XK60 accumulated. When “9” shows up, it means the operating hour reaches 10000h. When the filter reaches middle-level pollution, “2” will be shown at the first ③. place, When “0” shows up at the second place, the accumulated operating hour reaches 1400h.
  • Page 26 Wired Controler XK60 level, and then press “Enter/Cancel” button to activate it. If the setting pollution level is lighter than before, the icon will keep flashing. If the setting pollution level is more serious, the icon will go out, and the Filter function will keep on working.
  • Page 27 Wired Controler XK60 3.19 Ultra-Dry Setting Under Dry mode, when the setting temperature is 16°C, press “▼” button twice and the setting temperature will be changed to 12°C, at this time, the unit enters the Ultra-Dry function. When the Ultra-Dry function is activated, it can be cancelled by pressing “▲”...
  • Page 28 Wired Controler XK60 the remote controller will quit from the Enquiry function. If there is no operation in 20s, the unit will quit from this function automatically. Notes: If the unit is not connected with the ambient temperature sensor, after 12h ①.
  • Page 29 Wired Controler XK60 Fig.26 Indoor fan shutdown mode setting Note: In the parameter setting interface, only when “05” shown on it, the indoor fan shutdown mode can be set. Other parameters are not allowed to be modified and our company is not responsible for the unit damage or property loss due to parameter changed by customers.
  • Page 30 Wired Controler XK60 4.2 Installation Location and Installation Requirements (1). Do not install the wired controller in the damp place or under direct sunlight. (2). Do not install the wired controller close to the hi-temperature object or place where the wired controller is likely to suffer water spray.
  • Page 31 Wired Controler XK60 Fig.28 Installation of the Wired Controller Brief instructions: Pull out the 2-core signal line from the mounting hole and pass this line ①. through the round hole located at the bottom of the wired controller. Use M4×25 screws to fix the soleplate of the wired controller on the wall.
  • Page 32 Wired Controler XK60 When error occurs, please immediately shut down the unit and contact professional personnel. As shown in the Fig.30 means the high pressure protection. Fig.30 Error codes and their meanings: Table 5 Number Error code Error Compressor high pressure protection...
  • Page 33 Wired Controler XK60 Outdoor memory chip error Electric box sensor error Compressor overload protection Overloading IPM protection DC fan motor error Drive desynchronizing protection Pfc protection Humidity sensor error Activation failure Compressor phase sequence protection Power protection Indoor and outdoor mismatch...
  • Page 34 kaisai.com...