Rimage Producer II™
Replace a Quick-Release Recorder on an Amigo II
Use this procedure to replace a quick-release recorder in an Amigo II™.
Rimage approved parts must be used for this process. The product warranty may become void if parts not approved by Rimage are
used; equipment or parts are tampered with, misused, neglected, or modified in any respect without the written consent of Rimage.
Before you begin
1.
Stop or pause all jobs.
2.
Power off the external control center.
3.
Power off the autoloader.
4.
Disconnect the power cord from the power outlet.
Remove the Recorder
1.
Open the front door.
2.
Access the cables on the recorder to be replaced.
a.
Gently squeeze together the recorder's quick-
release tabs while the pulling the recorder out.
The recorder detaches from the system.
b.
Using the tab on the left, pull the recorder out
until you can access the cables.
3.
Disconnect the cables from the recorder.
•
Power cable
•
FireWire cable
Important! Disconnect the cables at the
positions indicated. Do not allow the cables to
fall back into the system.
Tip: Loosen the tie wrap to remove the
FireWire cable.
2000765_A
Required tools:
•
None required
FireWire Cable
© 2007, Rimage Corporation
Quick-Release Tabs
Tie Wrap
Power Cable
Operator
1