NoiseKen ISS-7630-CUP Instruction Manual

Coupling clamp

Advertisement

Quick Links

R
INSTRUCTION MANUAL
COUPLING CLAMP
ISS-7630-CUP
MODEL
N o i s e L a b o r a t o r y C o . , L t d .
Edition 1.01
AEJ00362-001-0B

Advertisement

Table of Contents
loading

Summary of Contents for NoiseKen ISS-7630-CUP

  • Page 1 INSTRUCTION MANUAL COUPLING CLAMP ISS-7630-CUP MODEL N o i s e L a b o r a t o r y C o . , L t d . Edition 1.01 AEJ00362-001-0B...
  • Page 2 NOTICE The contents of this instruction manual (the “Manual”) are subject to change without • prior notice. No part of the Manual may be reproduced or transferred, in any form and for any • purpose, without the permission of Noise Laboratory Co., Ltd.(the “Company”). The contents of the Manual have been thoroughly examined.
  • Page 3: Important Safety Precautions

    1. IMPORTANT SAFETY PRECAUTIONS The following instructions are very important for safe handling of ISS-7630-CUP (the “Unit”). Read them carefully before use. 1. Do not use the Unit near flammable materials or fire sources. When used, there is a risk of fire due to pulses, etc 2.
  • Page 4 Memorandum...
  • Page 5: Application Form Instruction Manual

    2. APPLICATION FORM INSTRUCTION MANUAL We place an order for an instruction manual. Model: ISS-7630-CUP Serial No.: Applicant: Company name: Address: Department: Person in charge: Tel No.: Fax No. Cut off this page “APPLICATION FORM FOR INSTRUCTION MANUAL” from this volume and keep it for future use with care.
  • Page 6 Memorandum...
  • Page 7: Table Of Contents

    3. CONTENTS 1. IMPORTANT SAFETY PRECAUTIONS ................1 2. APPLICATION FORM INSTRUCTION MANUAL ............3 3. CONTENTS ........................5 4. PREFACE........................6 5. BASIC SAFETY PRECAUTIONS ..................7 5-1. S ......................7 YMBOLS OF AZARD 5-2.B ................... 7 ASIC AFETY RECAUTIONS 5-3.
  • Page 8: Preface

    (the "Manual") thoroughly prior to use of the Unit in order to attain the maximum and safe use of the Unit.  The Manual will let you operate ISS-7630-CUP safely and make the most use of it if you strictly follow the operational procedures and the safety instructions.
  • Page 9: Basic Safety Precautions

    5. BASIC SAFETY PRECAUTIONS 5-1. Symbols of Hazard This sign indicates the presence of "dangerous voltage/current" that may endanger persons. This sign indicates "handle with care". Refer to the Manual to protect human bodies and devices. 5-2.Basic Safety Precautions There is a risk of electric shock. 【Precautions regarding use and safety】...
  • Page 10: Loss Of Warning Label

    10. The Company and its sales agent assume no responsibility for any bodily injury, loss, damage or resultant damage arising from derelict misuse of the Unit on the part of the user. 【Precautions regarding bodily injury, use, environment, and connection】 11.
  • Page 11: Main Features

    6. MAIN FEATURES 6-1. Features  This coupling clamp, ISS-7630-CUP (the “Unit”) complies with the ISO7637-3 (1995-07-15) Standard. The Unit allows easy testing when connected to pulse simulator (ISS-7630 or ISS-P3ab).  The Unit has a micro-strip line structure, and the characteristic impedance is 50Ω.
  • Page 12: Part Names And Functions

    7. PART NAMES AND FUNCTIONS ② ① ③ ④ Figure 2 ① Coupling Clamp ② Coaxial Connection Cable for a simulator. ③ Coaxial Connection Cable for a terminator. ④ Terminator...
  • Page 13 ① Coupling Clamp The coupling clamp main unit for coupling pulses to harnesses etc. The unit is utilized by inserting a harness into the plates of the clump located on the ceiling. Stray capacity arisen between the harness and the plate transmits the high frequency components onto the secondary side (harnesses) mainly by electrostatic inductions.
  • Page 14: Test Procedure

    8. TEST PROCEDURE 8-1. Test Preparation Before proceeding with the test, always carry out “10 Pre-Start Checkup (Waveform Verification).” Prepare the installation environment and connect the cables. Set up according to the Standard and/or other user requirements. An example is shown below. ・...
  • Page 15: Running Dut

    Since the waveform contains high frequency components over the range of 200MHz, the malfunction level cannot be measured quantitatively if the free capacity and the electromagnetic field radiation deviate due to placement of the simulator and DUT, types of cables used, and the height from ground plane. This highly depends on the physical positioning of devices under the testing environment.
  • Page 16: Product Specifications

    9. PRODUCT SPECIFICATIONS ・ Coupling Harness Measurements ····························· 4mm~40mm Diameter ・ Pulse Voltage Insulator Strength ······························ over 600V ・ VSWR (without Harness) ········································ less than 1.3 (~200MHz) ・ Input/Output Connector ·········································· BNC-R ・ Dimensions ·························································· (approximately) 1200mm×H70mm×D300mm ・ Weight ································································ (approximately) 3.5kg ・...
  • Page 17: Waveform Verification

    10. WAVEFORM VERIFICATION Before proceeding to the coupling clamp tests, confirm that the simulator is transmitting pulses normally. Refer to Figure 1. However, when verifying the waveform, harness must not be inserted into the clamper portion. Insertion of the harness will alter the characteristic impedance and cause reflections onto the waveform.
  • Page 18: Accessories

    11. ACCESSORIES Coaxial Cable ① Instruction (To Connect with Simulator) Accessories Manual Coaxial Cable② (To connect to Terminator) Terminator ③ For front panel フロントパネル用 For rear panel リアパネル用 Metal Fittings ⑤(for ISS-7630)
  • Page 19: Options

    12. OPTIONS 50Ω Load Waveform Verification ATT 00-00006A 20dB ATT Set of 2...
  • Page 20: Warranty

    13. WARRANTY Services The following terms are applicable to the services provided by the Company to maintain and repair the Unit. 1. Scope The Unit and accessories and options provided by the Company are covered under this section. 2. Technical Service Fee Any repairs provided by the Company during the warranty period will be free of charge in accordance with the Limited Warranty.
  • Page 21 Limited Warranty In the event of failure during the warranty period, the Unit will be repaired or replaced free of charge. Decision of the repair method shall be left at the discretion of the Company. This limited warranty is applicable in Japan only. Scope This warranty is applicable only to the Unit and its accessories.
  • Page 22: Maintenance

    14. MAINTENANCE Should the necessity of services such as repair, maintenance, or internal calibration arise, leave them to qualified service personnel only. Limit your own maintenance works to exterior surface cleaning and functional tests. When checking or changing replaceable fuses, turn OFF the power switches of the Unit and connected devices (if any).
  • Page 23: Noise Laboratory Support Network

    15. NOISE LABORATORY SUPPORT NETWORK  If a symptom which seems a trouble is found, inform the model name and serial number of the product together with the symptom to Noise Laboratory or your nearest sales agent of Noise Laboratory. ...
  • Page 24 NOISE LABORATORY CO., LTD. 1-4-4, Chiyoda, Sagamihara City, Kanagawa Pref., 229-0037, Japan TEL: +81-(0)42-712-2051 FAX: +81-(0)42-712-2050 URL: http://www.noiseken.co.jp Printed in Japan...