Page 3
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
Page 9
Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. TMSPGC PGA-370 SE/DIFF Clk Hardware Support...
Page 10
Terms on the Product. These terms may appear on the product: CAUTION indicates a hazard to property including the product. Symbols on the Product. The following symbols may appear on the product: Double CAUTION Protective Ground Insulated Refer to Manual (Earth) Terminal TMSPGC PGA-370 SE/DIFF Clk Hardware Support...
Page 11
Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. TMSPGC PGA-370 SE/DIFF Clk Hardware Support...
Page 12
Service Safety Summary TMSPGC PGA-370 SE/DIFF Clk Hardware Support viii...
Page 13
Preface This instruction manual contains specific information about the TMSPGC PGA370 microprocessor support package and is part of a set of information on how to operate this product on compatible Tektronix logic analyzers. If you are familiar with operating microprocessor support packages on the logic analyzer for which the TMSPGC PGA370 support was purchased, you will only need this instruction manual to set up and run the support.
Page 14
This phone number is toll free in North America. After office hours, please leave a voice mail message. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices. TMSPGC PGA-370 SE/DIFF Clk Hardware Support...
Page 17
The TMSPGC probe adapter is an interposer design. The probe adapter connects to the target system, and then, the microprocessor connects to the probe adapter.
(1.2 volt) or AGTLT (1.5 volt) logic levels. Refer to the AGTL specifications listed in Table 3- -5 on page 3- -6. CMOS The TMSPGC PGA370 hardware support can operate with only 1.5 volt CMOS logic levels. Refer to the CMOS specifications listed in Table on page . Target System Power Whenever you power off the target system, remove power from the probe adapter.
Page 19
SLP# TRST# BERR# DBSY# HIT# PRDY# SMI# TRDY# BCLK HITM# PREQ# Signals Not Acquired The following signals are not acquired by the TMSPGC probe adapter: PGA370 signal name PGA370 pin number BSEL[0] AJ33 BSEL[1] AJ31 CPUPRES# NCHCTRL PLL1 PLL2 RTTCTRL...
190-pin Mictor No gap on either end Interposer board Incorrect Correct Figure 1- - 1: Seating the 190-pin Mictor connector TMSPGC PGA-370 SE/DIFF Clk Hardware Support 1- - 4...
CAUTION. To prevent damage to the probe adapter, use the provided screws to secure the logic board to the Interposer board. Logic board Screws (2) Interposer board Protective socket Figure 1- - 2: Attaching the Logic board to the Interposer board TMSPGC PGA-370 SE/DIFF Clk Hardware Support 1- - 5...
Page 22
Do not install a protective socket without removing all existing sockets from the target system. 3. Choose the correct protective socket (see Figure 1- -3). When using the TMSPGC probe adapter: H Use the 363-pin protective socket only when using the JTAG port on the TMSPGC probe adapter.
363 pins JTAG protective socket Black holes are missing pins Figure 1- - 3: TMSPGC probe adapter protective sockets 4. Align the A3 pin indicator on the protective socket with pin A3 of the PGA370 protective socket on the target system.
7. Insert the probe adapter into the installed socket as shown in Figure 1- -5. Logic board Interposer board Pin A3 Target system Figure 1- - 5: Inserting the probe adapter into the socket TMSPGC PGA-370 SE/DIFF Clk Hardware Support 1- - 8...
Slave module. The portable logic analyzer has the lower numbered slots on the top and the benchtop logic analyzer has the lower numbered slots on the left. TMSPGC PGA-370 SE/DIFF Clk Hardware Support 1- - 9...
S_A, S_C, and S_D probe connectors on the probe adapter. Align the pin 1 indicator on the probe label with pin 1 of the connector on the probe adapter. 5. Repeat steps 2 and 3. TMSPGC PGA-370 SE/DIFF Clk Hardware Support 1- - 10...
Figure 1- -8 shows the location of J140 and J160 on the probe adapter. Frequency MODE J160 J140 Logic board Figure 1- - 8: Jumper locations on the TMSPGC probe adapter TMSPGC PGA-370 SE/DIFF Clk Hardware Support 1- - 11...
Getting Started Alternate Connections JTAG The TMSPGC probe adapter logic board provides J490 as a way to connect to JTAG debugging hardware. JTAG debugging hardware is not included with the TMSPGC PGA370 hardware support package. Contact your microprocessor vendor for information on how to obtain JTAG debugging hardware.
Four pins on J150 are provided to connect the TMS801 APIC bus probe adapter to the PICCLK, PICD0, and PICD1 signals for APIC bus support. The TMS801 APIC bus probe adapter is not included with the TMSPGC hardware support package. Contact a Tektronix representative for information on how to obtain the TMS801 APIC bus probe adapter.
Getting Started Figure 1- -10 show the APIC bus signal pins for the TMSPGC probe adapter. APIC J150 Figure 1- - 10: APIC pin locations on the probe adapter Applying and Removing Power An AC adapter for the TMSPGC probe adapter is included with this TMSPGC PGA370 hardware support.
NOTE. Failure to power down the target system before removing power from the probe adapter may cause erratic behavior. 1. Power off the target system. 2. Unplug the AC adapter for the probe adapter from the electrical outlet. TMSPGC PGA-370 SE/DIFF Clk Hardware Support 1- - 15...
Page 32
Getting Started TMSPGC PGA-370 SE/DIFF Clk Hardware Support 1- - 16...
Page 47
The following is a description of Signal Probing and JTAG circuitry. Signal Probing The TMSPGC probe adapter uses series isolation resistors on all signals. For most signals (see Figures 3- -1 to 3- -3), the probe adapter presents an active device load.
75 Ω (impedance) Specification Tables These specifications are for the TMSPGC probe adapter connected between a Tektronix logic analyzer and a system under test. Table 3- -2 lists the electrical requirements of the system under test. Table 3- -7 lists the electrical requirements for the AC adapter that provides power to the TMSPGC probe adapter.
100 -- 250 VAC CAT II Input Frequency Rating 47 -- 63 Hz Input Current Rating 1 A Maximum, at 90 VAC Output Voltage Rating Output Current Rating Output Power Rating 40 W TMSPGC PGA-370 SE/DIFF Clk Hardware Support 3- - 6...
15 km (50,000 ft) maximum Electrostatic immunity The probe adapter is static sensitive Designed to meet Tektronix standard 062-2847-00 class 5. Not to exceed microprocessor thermal considerations. Forced air cooling may be required across the CPU. TMSPGC PGA-370 SE/DIFF Clk Hardware Support...
Specifications Dimensions Figure 3- -6 shows the dimensions of the TMSPGC probe adapter. 104.14 mm 152.40 mm (4.10 in) (6.00 in) 1387.16 mm (5.4 in) Front View 96.52 mm (3.80 in) 40.60 mm 40.60 mm Side View (1.600 in) (1.600 in) 19.05 mm...
If the fuse on the probe adapter opens (burns out), you can replace it with a 7 A, 125 V fuse. Figures 4- -1 illustrates the location of the fuse on the TMSPGC probe adapter. See the Replaceable Mechanical Parts chapter for part descrip- tions.
Page 61
This section contains a list of the replaceable components for the TMSPGC PGA370 Hardware support package. Parts Ordering Information Replacement parts are available through your local Tektronix field office or representative. Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements.
Page 62
Items in this section are referenced by figure and index numbers to the exploded view illustrations that follow. Tektronix part number Use this part number when ordering replacement parts from Tektronix. 3 and 4 Serial number Column three indicates the serial number at which the part was first effective. Column four indicates the serial number at which the part was discontinued.
Page 63
16640 SW 72ND AVE PORTLAND, OR 97224 61429 FOX ELECTRONICS DIV OF FOX ENTERPRIXED INC FORT MEYERS, FL 33905 5842 CORPORATION CIRCLE 61857 SAN--O INDUSTRIAL CORP 91--3 COLIN DRIVE HOLBROOK, NY 11741 TMSPGC PGA-370 SE/DIFF Clk Hardware Support 5- - 3...
Page 64
CIRCLE,0.73 H X 0.140 TAIL,SHLD W/MTG HOLES, STANDARD ACCESSORIES 071--0803--01 MANUAL,TECH:INSTRUCTION,PGA--370 SINGLE ENDED TK2548 071--0803--01 DIFFERENTIAL CLOCK HARDWARE,TMSPG,DP 161--0104--00 CA ASSY,PWR:3,18 AWG,98 L,250V/10AMP,98 S3109 ORDER BY INCH,RTANG,IEC320,RCPT X STR,NEMA 15--5P,W/CORD DESCRIPTION GRIP, TMSPGC PGA-370 SE/DIFF Clk Hardware Support 5- - 4...
Page 65
CA ASSY,PWR:3,0.75MM SQ,250V/10A,2.5 S3109 ORDER BY METER,RTANG,IEC320,RCPT,SWISS,NO CORD DESCRIPTION GRIP,SAFTEY CONTR Check the P6434 manual for detailed replaceable part number information. The above part numbers apply to the prototype product (TMSPGCP) TMSPGC PGA-370 SE/DIFF Clk Hardware Support 5- - 5...
Page 66
Replaceable Parts List Figure 5- - 1: Exploded view of the TMSPGC PGA370 probe adapter TMSPGC PGA-370 SE/DIFF Clk Hardware Support 5- - 6...
Page 67
Replaceable Parts List TMSPGC PGA-370 SE/DIFF Clk Hardware Support 5- - 7...
Page 68
Replaceable Parts List TMSPGC PGA-370 SE/DIFF Clk Hardware Support 5- - 8...