PRE-OPERATING INSTRUCTIONS

  1. Be sure the humidifier is switched off (knob turned all the way to the left).
  2. Select a location for your humidifier, on a flat level surface about 4 inch away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by too much moisture or water. Place on a moisture resistant surface.
  3. Remove the tank from the main housing.
  4. Bring the tank to the sink, turn upside down and twist off the tank cap by turning counter clockwise. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY.
  5. Place tank back on to the base. The tank will immediately begin to empty into the base.
  6. Plug the humidifier into a 120V electrical outlet.

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS - Device Overview

  1. Tank
  2. Humidifier Base
  3. Volume Control
  4. Mist Nozzle
  5. Transducer (Not Shown )
  6. Mist Chamber
  1. To turn the unit on, turn the Volume Control knob Clockwise. Turning the knob all the way to the right will produce the highest moisture. Turning to the left will produce lower moisture with longer run time.
  2. When the humidifier runs out of water, the transducer will automatically shut off and the fan will keep running to dry any residual water out of the base and chamber.
  3. Once the tank is empty, turn the Power Off and unplug the unit.
  4. Before refilling the tank, empty any residual water from the base and tank. Follow daily maintenance instructions.
  5. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY.
  6. Place tank on the base. The tank will immediately begin to empty into the base.
  7. Plug the humidifier into a 120V electrical outlet.


DO NOT move the humidifier with water in the tank or the humidifier base. The moving action of the water may activate the water tank's release nozzle and overfill the transducer cavity. This may cause the humidifier to function intermittently, or stop emitting mist. Should this occur, simply remove the excess water from the humidifier base.


If you do not plan to use your humidifier for two or more days, make sure any residual water is drained from the water tank and base to prevent any algae or bacteria growth in stagnant water. Make sure the tank is dry.

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.

In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the humidifier's tank and become airbone. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.

DAILY MAINTENANCE

  1. Be sure the unit is OFF and is disconnected from the electrical outlet.
  2. Remove the tank from the humidifier and place in sink or tub.
  3. Drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean and dry with a clean cloth or paper towel.
  4. Refill with cool tap water. Do not overfill.

WEEKLY MAINTENANCE

To Remove Scale:

  1. Repeat steps 1-3 above.
  2. Clean all surfaces with a soft brush. Gently scrub the area around the transducer with a soft brush. Remove the scale by wiping the entire base with a cloth dampened with undiluted white vinegar.
  3. Rinse clean with warm water to remove cleaning solution before disinfecting the tank.

To disinfect tank

  1. Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach.
  2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.
  3. Carefully empty the tank after 20 minutes, and rinse with warm water until you can not detect any bleach smell. Dry with a clean cloth or paper towel.
  4. Refill the water tank as directed in Operating Instructions, and turn the unit on.

STORAGE INSTRUCTIONS

When not using your humidifier for an extended period of time:

  1. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season.
  2. Place the humidifier in the original carton and store in a cool, dry place.

TROUBLESHOOTING

TROUBLE PROBABLE CAUSE SOLUTION

Water Leaks from tank

Tank rubber ring is missing Remove tank cap and replace or reposition ring
Cap not tight enough Tighten the cap
Tank water is Hot Fill with cool water only Don't move when full

Crack in Tank

Hot water will cause tank to pressurize Fill with cool water only
Tanks will crack if hit or dropped Handle tank with Care

Film on tank

Mineral deposits Clean/disinfect tank as instructed in weekly cleaning instructions

Fan on, but no Mist

Volume too low Turn up volume control
Might be running out of water Fill tank with cool water

FREQUENTLY ASKED QUESTIONS

QUESTIONS ANSWER

What are the variables that affect run time

The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as:
  1. Air exchange in the room where the humidifier is placed.
  2. Room construction where the humidifier is placed.
  3. Temperature of the room where the humidifier is placed.
  4. Humidity levels in the room where the humidifier is placed.
  5. Movement of occupants and the opening and closing of doors in the room where the humidifier is placed.
  6. Home furnishings in the room where the humidifier is placed.

How do I remove film on water tank

See Daily Maintenance instructions. Regular cleaning is recommended.

How can I extend the run time

  1. Run your unit on the lowest setting.
  2. If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time.
  3. Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Holmes HM495 - Filter Free Ultrasonic Humidifier Owner's Manual

Advertisement

Need help?

Need help?

Do you have a question about the HM495 and is the answer not in the manual?

Questions and answers

Table of Contents