Do you have a question about the GK-E Series and is the answer not in the manual?
Questions and answers
Summary of Contents for GATEXPERT GK-E Series
Page 1
INDUSTRIAL DOOR OPERATOR WITH ELECTRONIC LIMIT SWITCH USER MANUAL (GK-E SERIES Website: www.gatexpertstore.com E-mail: sales@gatexpertstore.com...
Page 2
All personal information you provided will be only used for warranty service and kept strictly confidential. Refer to this list when contacting GATEXPERT for technical service or assistance with your automatic gate opener. Order Number Product Model...
Page 3
Instructions for GK-E SERIES Safety Instruction 1. The industrial door operator should be installed and put into operation by qualified personnel. Otherwise, serious personal injury or property damage may occur. 2. Installation and wiring must be in accordance with the construction standards and electrical standards, diameter ≧...
Instructions for GK-E SERIES Technical Parameter Table of Door Operator Model (Single Phase AC220V±10%) GK30E GK40E GK100E Rated Power 230W 300W 550W Torque 30N.m 40N.m 100N.m No-load Continuous Running Time 15 min. 8 min. Max. gate area Model (Three Phase AC380V±10%)
Instructions for GK-E SERIES Technical Parameter Table of Control Unit Model GKB220E GKB380E Power Supply AC220V/50Hz AC380V/50Hz Remote Control Available Available Applicable Model GK30E/40E/100E GK60SE/100SE External Three Button Switch Terminal Available (Optional) Available (Optional) External Single Button Switch Terminal Available (Optional)
Page 7
Instructions for GK-E SERIES Electronic limit switch part ② Gearbox ③ Wiring terminals ④ Plastic cover ⑤ Door operator ⑥ Hand-pulled chain ⑦ Release handle Component Control Unit Dimension www.gatexpertstore.com...
Instructions for GK-E SERIES Installation Guide of Industrial Door Operator This product is commonly used for the industrial sectional door which was equipped with balance spring and lifting industrial door. There are two installation ways for this product: shaft drive installation and chain drive installation. The factory standard configuration is for shaft drive installation.
Page 9
Instructions for GK-E SERIES Step 1. Check the door After the door is installed, adjust the torsion spring, ensure manually opening or closing the door is flexible without stagnation, observe the rotation direction of the rope sheave which should be consistent with the opening and closing direction of the industrial door operator.
Page 10
Instructions for GK-E SERIES Step 3. Trial installing the door operator Install a fixing sleeve on door shaft first, and insert the industrial door operator into the door shaft. Step 4. Pre-fix the industrial door operator Fix the industrial door operator on mounting bracket with 4pcs hexagon head flange bolts M10×20, do not tighten at this step.
Page 11
Instructions for GK-E SERIES Step 5. Find the direction of key slot First pull the red handle A to the bottom to make the hand-pulled chain mechanism e ngage with the main engine (Manual control mode). Rotate the output shaft of industrial door operator by pulling the hand-pulled chain up and down until the key slot of the output shaft is fully aligned with the key slot of the door shaft.
Instructions for GK-E SERIES Industrial Door Operator Wiring Wiring Between Door Operator and Control Unit 1. Motor Wire 2. Encoder Wire 3. Power Supply Wire www.gatexpertstore.com...
Page 13
Instructions for GK-E SERIES Wiring of Single Phase Operator ——Motor Wire: U(blue) V(brown) W(black) ——Encoder Wire: GND(white) A(yellow) B(red) VCC(green) ——AC220V(single phase) Power Supply Wire Note: Please make sure the wirings are tight and in good connection. After wiring, remember to tighten up the IP plug to ensure all wirings completely fixed.
Page 14
Instructions for GK-E SERIES Wiring of Three Phases Operator ——Motor Wire: U(blue) V(brown) W(black) ——Encoder Wire: GND(white) A(yellow) B(red) VCC(green) ——AC380V(three phases) Power Supply Wire Note: 1. Please make sure the wirings are tight and in good connection. After wiring, remember to tighten up the IP plug to ensure all wirings completely fixed.
Instructions for GK-E SERIES Operation Interface Illustration DIGITAL SCREEN OPEN STOP STOP DOWN NEXT CLOSE INDICATOR LIGHT INCREASE REDUCE CONFIRM Opening status Working mode Input status display display display OPEN STOP CLOSE www.gatexpertstore.com...
Instructions for GK-E SERIES Open and Closed Limit Switch Setting After powering on, the digital will display E-03 (hasn’t set the OPEN limit switch) STOP CLOSE Press and hold OPEN “NEXT” for 3 seconds, the digital STOP will display 00000...
Page 17
Instructions for GK-E SERIES OPEN Press “confirm” once; The digital will display P1-F1; press “confirm” once again; STOP The digital will display — — CLOSE Shortly press “OPEN” to check OPEN opening direction, if it’s correct, then press and hold “OPEN” to set...
Page 18
Instructions for GK-E SERIES Release the “OPEN” when OPEN motor arrives at the open STOP limit switch position, press “CONFIRM”, the digital will CLOSE display the encoder value for 1 second and then show — —, then you can set the closed limit switch position.
Instructions for GK-E SERIES Working Mode Setting Press and hold “-” for 4 seconds, you can select manual control or automatic control mode. OPEN 1. Automatic(A): Press “OPEN”, the door will run to the open limit switch position, STOP after...
Instructions for GK-E SERIES Input Status: Input Status Instruction Stop Open Close Photo Sensor Air Bag Loop Detector Partial Opening Single Cycle Interlock Parameters Setting Parameters Value Range Default P1-F1 Electronic limit switch setting Pre-stop before arriving at the open...
Page 21
Instructions for GK-E SERIES P2-F8 Restore to factory setting of P2 0=No;1=Yes P3-F1 Multi-function of F1 0=NO;1=NC P3-F2 Multi-function of F2 0=NO;1=NC Close Fault output Door completely open in place output Door partially open in place output Not open limit switch output...
Instructions for GK-E SERIES External Accessories Wiring 1. External three-buttons switch terminal: “STOP” terminal type is NO by default, if you need NC type, please modify the setting of “P2-F1” to be “1”. External three-buttons switch Partial opening button switch...
Page 23
Instructions for GK-E SERIES 4. Safety photocell terminal: terminal type is NO, if you need NC type, please modify the setting of “P2-F4” to be “1”. The valid height of photocell can be adjusted under “P3-F6”. Safety aibag Loop detector...
Instructions for GK-E SERIES please remove the jumper wire between “DIND” and “COM” 8. Relay terminal output: default is NO, if require NC type, please modify the setting of “P3-F1” or “P3-F2”to be “1”. Output logic function can be selected under “P3-F3” and “P3-F4”.
Instructions for GK-E SERIES Note: Only need to pair “button A”, the pairing of the remote control is finished meanwhile. Remote control delete: b、 Press and hold AN button on the receiver, LED light will be on, release the button until the LED light is off, all paired remote controls are deleted.
Instructions for GK-E SERIES machine, the control unit can work properly until the E--06 is off. 2. In the process of electrically opening or closing of door, chain is strictly prohibited to be pulled, to avoid any accidents. 3. Hand-pulled chain is used for special circumstances such as power outage only, and cannot be used as a long-term normalized operating.
Instructions for GK-E SERIES Waiting for the motor to cool down. E-06 Thermal protection or hand Thermal protection chain protection pull green handle B to the bottom to close the disengagement wrench. Close the smaller door to enable it’s E-07 normal running.
Need help?
Do you have a question about the GK-E Series and is the answer not in the manual?
Questions and answers