Page 1
ITEM # MODEL # ITEM DESCRIPTION MANUFACTURER REMARKS See Manuf. CC104.B CR 150 Ice storage cabinet- 96" x 48"- with Leer VND VND Delivered and installed by vendor. Specifications Leveler kit (added 2019) EQUIPMENT CELL INFORMATION Date created: 4/18/2016 Date revised:...
Page 2
ORNER EFRIGERATION NITS Model: CR150 Automatic Defrost Compressor: ¾ HP Refrigerant Charge: 17.5 ounces of R404a Electrical Rating: 12.5 Amps Capacity: Approximately 600 Seven-Pound Bags Cabinet Dimensions: 96” Wide x 48” Deep x 75” Tall (there is a 1” high rail under the cabinet so the overall height is 76”...
Page 4
AUTO-DEFROST TROUBLE SHOOTING CHART – MECHANICAL CONTROL.. 16 XIII. REPLACEMENT PARTS……..………………………………………………………. 17-18 NOTES …………………………………………………………………………………………….. 19 WARRANTY………………………………………………………………………………….…...…20 Material and product improvement is a continuous commitment at Leer. This manual is subject to modification or change without notice and without incurring responsibility for previously sold merchandisers and components.
Page 5
Contact the Merchandiser Sales Department housing and any wall surface behind the cabinet, to at Leer, Inc. for additional information. allow for some heat dissipation away from the surface of the wall. The main power cord should be...
Page 6
Note: Do not operate an indoor auto-defrost plate will indicate the maximum fuse/circuit breaker merchandiser without having a condensate size required for that specific merchandiser model. evaporator assembly installed over the evaporator Note: Operating more than one appliance on the drain tube exiting the back wall of the cabinet.
Page 7
Mechanical Controls: Defrost Timer !!!"#-$./%+!-)#&01234"# The defrost timer is located on the top of the Each merchandiser has been run and leak tested merchandiser, under the cover housing the during the course of its’ manufacture. The merchandiser’s condensing unit. The timer will merchandiser will arrive at the customer location engage the merchandiser’s defrost cycle once every ready to operate within design parameters that have...
Page 8
Merchandiser Division line hole and into the unit cooler assembly, which is Customer Services for Leer, Inc, can be reached by mounted to the interior ceiling of the cabinet. The phone at 1-800-766-5337, or e-mail contact...
Page 9
system pressures and temperatures, and ultimately a !!!"#-$./%+!-)#&01234"# compressor failure. It’s recommended that the condenser coil and fan blade be inspected, and Loading Ice: The merchandiser should be pre- cleaned, at least once every 3 months. These chilled prior to loading with ice. Pre-chilling will intervals will often vary depending upon the aid the merchandiser in reaching storage environment the merchandiser is operating in.
Page 10
!5"#6%!)+.)%)&.#701234"# “Normal” position after the defrosting process is Defrosting the merchandiser: It is the function of completed, to re-energize the condensing unit). If the evaporator coil to remove heat from the air in the cold wall cabinet has an “electronic control”, the merchandiser.
Page 11
!5"#6%!)+.)%)&.#701234"# the control will override the timed cycle and On indoor cabinet models, the consumer needs to immediately switch power from the defrost mode to install the condensate evaporator heater assembly the run mode. If temperature is not reached at (described in the INSTALLATION section of this probe “P2”, the defrost cycle will continue for the manual) onto the exterior back wall of the cabinet.
Page 12
“Arlon DPF 8000 Laminate” are available upon adjusted. Removing the hinge covers will expose request to the Customer Service Dept. at Leer, Inc. the spring-loads for tension adjustment or removal. Removal of the spring-load will expose the hinge-...
Page 13
Door gaskets on outdoor cabinet models may !5"#6%!)+.)%)&.#701234"# mildew and stiffen over time. The gasket is made of a soft, flexible PVC and can be cleaned using most kitchen and bath cleaners designed for mildew removal. Review manufacturer information and instructions on any cleaning agent prior to use to determine the cleaners’...
Page 18
K!"#&0:4#8;::#+=0CM:BD*L002<1>#J:0N#&L;=2#A#6B7L;1<7;:#&012=0:# K!"#&0:4#8;::#+=0CM:BD*L002<1>#J:0N#&L;=2#A#6B7L;1<7;:#&012=0:# K!"#&0:4#8;::#+=0CM:BD# K!" &0:4 8;:: +=0CM:B ################################################################ Cabinet is not maintaining temperature Condensing unit fan motor is running Compressor is running Compressor is running *L002<1>#J:0N#&L;=2#A#6B7L;1<7;:#&012=0:# No power at service outlet Thermostat is turned to “OFF” position Low voltage on start up Faulty thermostat Faulty connection to compressor windings Open circuit in cabinet wiring...
Page 20
Note: Providing the cabinet model and serial number may aid in identifying parts for a specific merchandiser. Return only authorized parts to this address: Leer, Inc. 206 Leer St. New Lisbon, Wi. 53950 - Contact the Leer Merchandiser Customer Service Dept. to obtain a Return Material Authorization (RMA) Number )-+.P#,BB=#B:B72=<7;:#;14#=BE=<>B=;2<01#Q;=2F#;=B#<1F2;::B4#<1#70@Q:<;17B#20#G","#*2;14;=4#RST"###/BQ:;7B@B12#0E#Q;=2F# 2L;2#;=B#102#G","#&B=2<E<B4U#0=#;=B#102#<4B12<7;:#20#2LB#-.6#<1F2;::B4#Q;=2U#@;V#W0<4#2LB#@B=7L;14<FB=3F#G","#,<F2<1>#;14X0=# 2LB#J;720=V#N;==;12VU#QB=#Y(B1B=;:#$=0W<F<01FZ#0E#2LB#;770@Q;1V<1>#N;==;12V#F2;2B@B12"#...
Page 22
Year & Month of Manufacture U = Upright G = Glass Manufacturer 15 = 2015 S = Slant L = Leer S = Solid 01 = January L = Low Etcetera …… L 075 U A G E - 1501 01234 Options Individual I.D.