Download Print this page

Ordering Information - Cooper Lighting Ovation Brochure

Cooper lighting recessed direct/indirect luminaire brochure

Advertisement

2RDI-S-2BX40RP
Electronic Ballast
F40BX/35K/RS Lamps
3150 Lumens
Spacing criterion:
(II) 1.2 x mounting height,
(⊥) 1.3 x mounting height
Efficiency 67.9%
Test Report #223P115
LER= FL55
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $4.36
Zonal Lumen Summary
Zone
Lumens
%Lamp
%Fixture
0-30
1114
17.7
26.1
0-40
1825
29.0
42.7
0-60
3249
51.6
76.0
0-90
4276
67.9
100.0
0-180
4276
67.9
100.0

Ordering Information

Sample Number:2RDI-232RP/TBW-120V-EB51-U
2
RDI
Blank=1' Width
2=2' Width
Ovation Series
RDI=Recessed
Direct/Indirect
Trim Type
Leave Blank=Grid/Lay-in
(Standard)
Trim Type
Leave Blank=Center Mounted
Lamps (Standard)
S=Side Mounted Lamps
ASY=Asymmetric
Number
of Lamps
(Not included)
1=1 Lamp
2=2 Lamp
3=3 Lamp
4=4 Lamp
T1=2' x 4' Fixture with One Biax Lamp at Each End
T2=2' x 4' Fixture with Two Biax Lamps at Each End
T3=2' x 4' Fixture with Three Biax Lamp at Each End
NOTE:
1
2' x 2' and 2' x 4' Center Lamp Shield models only.
2
Products also available in non-U.S. voltages and frequencies
for international markets.
Zonal Lumen Summary
Zone
Lumens
0-30
476
0-40
765
0-60
1287
0-90
1555
0-180
1555
2
32
RP/TBW
Wattage (Length)
17=17W T8 (24")
32=32W T8 (48")
BX40=40W Biax (24")
1
BX50=50W Biax (24")
1
BX55=55W Biax (24")
1
14T5=14W T5 (24")
1
24T5=24W T5HO (24")
1
28T5=28W T5 (48")
1
54T5=54W T5HO (48")
Lamp Shield
X=Solid Matte White
RP=Round Perforated White Steel
RP/TBW=Round Perforated White Steel w/Thin Blade
1
White Baffle
RP/PLI=Round Perforated White Steel w/Semi- Specular
1
Parabolic Baffle
RP/PLMI=Round Perforated White Steel w/Specular
1
Parabolic Baffle
RPD=Round Perforated Steel Below Ceiling Lamp Shield
RPD/TBW=Round Perforated Below Ceiling Lamp Shield
w/Thin Blade White Baffle
1
FLS=Frosted Lamp Shield
1
SLS=Split Lamp Shield
Options
GL=Single Element Fuse
GM=Double Element Fuse
LAMPS=Lamps Installed
FLEX=Flex Installed
EMERGENCY=EM Installed
ST=Silver Tannenbaum Reflector
RDI-214T5RP
Electronic Ballast
F14T5/835 Lamps
1350 Lumens
Spacing criterion:
(II) 1.2 x mounting height,
(⊥) 1.2 x mounting height
Efficiency 57.6%
Test Report #226P115
LER= FD46
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $5.22
%Lamp
%Fixture
17.6
30.6
28.3
49.2
47.7
82.7
57.6
100.0
57.6
100.0
2
Voltage
120V=120 Volt
277V=277 Volt
Ballast Type
347V=347 Volt
Blank=Standard Magnetic Ballast (40W Biax only)
UNV=Universal
EB8 =T8 Electronic Instant Start
Voltage 120-277
Total Harmonic Distortion < 20%
No. of Ballast
1, 2 or 3
EB8 / PLUS= T8 Electronic Instant Start
No. of
Ballast
1, 2 or 3
ER8 =T8 Electronic Program Rapid Start
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
TEB8 = T8 Electronic Instant Start
No. of Ballast
1, 2 or 3
EB5 =T5 Biax Electronic Instant Start
Total Harmonic Distortion < 20%
No. of Ballast
1, 2 or 3
TEB5 = T5 Biax Electronic Instant Start
No. of Ballast
1, 2 or 3
EBT =T5 Linear Electronic Program Rapid Start
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
RDI-ASY-1BX40RP
Electronic Ballast
F40BX/35K/RS Lamps
3150 Lumens
Efficiency 68.3%
Test Report #226P107
LER= FL54
Yearly Cost of 1000
lumens, 3000 hrs at .08
KWH = $4.44
Zonal Lumen Summary
Zone
Lumens
%Lamp
%Fixture
0-30
580
18.4
27.0
0-40
955
30.3
44.4
0-60
1704
54.1
79.2
0-90
2151
68.3
100.0
0-180
2151
68.3
100.0
Options
Packaging
U=Unit Pack
PALC=Job Pack, in Carton
High Ballast Factor > 1.13
Total Harmonic Distortion < 20%
Total Harmonic Distortion < 10%
Total Harmonic Distortion < 10%

Advertisement

loading