TPU Series Instruction Manual Self-prime Pump Model : 1100 / 1500 To ensure safe and proper use, please read this instruction before operation. ISO 9001 Certified Walrus America Inc.
4.1 We recommend outlet and inlet 1. Application should stay the same size as the original. If you marrow the pipe 1.1 The TPU Series is single-stage size, it will affect the performance centrifugal pump designed for of the pump.
Page 3
6. Start-Up 5.4 For your safety, please make sure that the wiring is correctly ground- Before starting the pump, make sure the following: 6.1 For three phase motors, verify if 5.5 To avoid the possibility of dry the rotating direction is correct. It running, we strongly recommend should be clockwise viewing from installing dry running protection.
7.4 When pump is not in use for a 9. Wiring Diagram period, it should be drained. For Single Phase start up after long time inactivity please check if the impeller and mechanical seal are free. If they are locked up by sand, rust or something else please clean them 7.5 DO NOT use the pump should not be used to transfer toxic or...
Page 5
10. Fault Finding Make sure to disconnect the power before attempting to diagnose any fault. Fault Cause Remedy Supply failure. Connect the electricity supply. 1. Motor does not run start. Fuses are blown. Replace fuses. Motor starter overload has Reactivate the motor protection. tripped out.
Page 6
11. Dimensions TPU 1100 / 1500 Rp 2” Rp 2” 12. Performance Model TPU 1100 TPU 1500 Max. pumping depth Max head (m) 23 m 28 m Max flow (L/min) Pole 2 pole Output power (P2) 1.1 kW 1.5 kW Inlet / Outlet Rp 2”...