Power Take Off • PTO Horsepower and torque rating must be adequate for desired blower RPM and pressure demand. (See P657 Blower Specifications Fig.1, Page 4) • Select proper ratio for the desired engine speed and correct blower input shaft speed.
• Must allow minimum of 3/4” clearance between the blower and frame rail to prevent damage to the blower. • Use Qty (4), 5/8” diameter bolts to mount the P657 Mounting Bracket to the tractor frame rail. Drive Shaft Installation Caution Drive shaft and other components may shift with changes in suspension.
Ensure Vacuum Relief Valve is sized for the correct CFM. Ensure Vacuum Relief Valve rating does not exceed 15 inHg. A Vacuum Relief Valve should be positioned between the filter outlet and P657 Inlet Flange. Caution If operating under vacuum a Vacuum Relief Valve should be installed.
• Paragon recommends that a factory dealer/technician program your tractor for optimal ECM/TCM performance. • Ensure the engine range RPM is programmed within the operational limits of the P657 Blower. • Ensure the engine RPM ramp up rate, after PTO engagement, is set for no more than 100 rpm per second.
• If blower relief valve or melt plug is activated, reduce the line pressure to 0 psi. - Shut down the P657 by disengaging the PTO, shut off the engine, and check for blockages • Disengage P.T.O. according to manufacturer’s instructions, shut off engine.
Lubrication Instructions • Use Paragon Lobe Blower Oil (part number: 409-007). Note: Front oil tank will fill slower than the rear tank. Allow oil to settle after it begins to show in the sight glass. (Fig. 6) Max Oil Fill Level...
Preventative Maintenance • A proper maintenance program will keep your P657 blower in top running condition. A newly installed P657 blower should be checked frequently during the first month of operation. Use only Paragon Blower Oil. Check oil levels and add as needed.
The correct Relief Valve has been installed properly. Melt Plug is installed on the discharge side of the blower. Sight glasses and magnetic drain plug can be seen to identify oil level in P657 oil tanks after installation. Breathers are installed in the proper location.
WARRANTY - TRUCK BLOWERS Subject to the terms and conditions hereinafter set forth in General Terms of Sale, Paragon Tank Truck Equipment LLC (the Seller) warrants products and parts of its manufacturer, when shipped and its work (including installation and start-up) when performed, will be of good quality and will be free from defects in material and workmanship.
Need help?
Do you have a question about the P657 and is the answer not in the manual?