XSA SERIES
SPUN ALUMINUM EXHAUSTER
OPERATION INSTRUCTIONS AND PARTS MANUAL
READ AND SAVE THESE INSTRUCTIONS
The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions are intended to supplement good
general practices and are not intended to cover detailed instruction procedures.
IT IS THE RESPONSIBILITY OF THE PURCHASER TO ASSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS EQUIPMENT IS
HANDLED BY QUALIFIED PERSONNEL.
Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER'S BILL OF LADING AND FILE A
CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.
DO NOT LIFT THE UNIT BY THE HOOD OR MOTOR. PLEASE LIFT THE UNIT BY HORIZONTAL SUPPORTS.
GENERAL SAFETY
1. All electrical work must be done in accordance with all applicable electrical codes by a
qualified electrician.
2. Prior to wiring ensure the power supply is locked in the OFF position and that the motor
nameplate voltage matches the supply voltage.
3. Do not install or operate this fan in an environment where combustible materials, gases or
fumes are present.
4. Caution: the fan contains rotating parts and electrical service. Appropriate safety
precautions should be taken during installation, operation and maintenance.
When servicing the fan motor may be hot, allow time for cooling down.
5. Before starting the unit, ensure the wheel rotates freely.
6. Check and tighten where necessary all nuts, bolts & set screws prior to fan start up (as
some may have loosened during shipment).
7. Please follow all applicable national, state/provincial and local codes, all of them will
supersede this manual.
8. Failure to follow the safety instructions in this manual may cause serious injury or
death due to electrical shock or high speed rotating parts.
DIMENSION & COMPONENT
UPBLAST
MODELS
Upblast Belt
Drive Shown
A
D
Motor plate detail varies
on different sizes
Model XSA
A
B
C
XSA105-UD
17.63
25.00 19.00 13.00 1.50
XSA120-UD
18.63
25.00 19.00 13.00 1.50
XSA135-UD/UB
22.25 / 25.25 32.13 21.00 17.13 1.50
XSA150-UD/UB
23.13 / 26.13 32.13 21.00 17.13 1.50
XSA165-UD/UB
27.13 / 31.13 37.50 24.75 21.13 2.00
XSA180-UD/UB
27.75 / 31.75 37.50 24.75 21.13 2.00
XSA10-UB
36.25
43.75 33.13 25.50 2.50
XSA245-UB
37.00
43.75 33.13 25.50 2.50
XSA-M-10_04_16
B
E
F
G
C
Dimensions (inches)
Wheel
D
E
F
G Ø
Diameter
Opening
3.50
0.38
10.50
3.50
0.38
12.25
3.75
0.44
13.50
3.75
0.44
15.00
4.00
0.44
16.50
4.00
0.44
18.25
4.00
0.44
21.25
4.00
0.44
24.50
Note: Belt drive units are weighted without motor & drives.
NOTE: DUE TO MOTOR MANUFACTURERS VARIANCES IN DESIGN,
!
PLEASE SEE PAGE 5 FOR MOTOR DIMENSIONAL GUIDELINES.
DOWNBLAST
MODELS
Downblast Direct
Drive Shown
Net
Roof
Weight
Model
(lbs)
XSA105-DD
15.00
35
XSA120-DD
15.00
37
XSA135-DD/DB
17.00
53 / 62
22.25 / 25.25 31.25 21.00 3.13
XSA150-DD/DB
17.00
58 / 67
23.13 / 26.13 31.25 21.00 3.75
XSA165-DD/DB
20.75
100 /108
27.13 / 31.13 36.25 24.75 5.00
XSA180-DD/DB
20.75
108 / 116
27.75 / 31.75 36.25 24.75 5.50
XSA210-DB
29.00
178
XSA245-DB
29.00
183
UPBLAST
B
A
D
F
C
Dimensions (inches)
A
B
C
D
E
F
18.00
25.00 19.00 2.50
1.50
3.50
19.00
25.00 19.00 3.50
1.50
3.50
2.00
3.75
2.00
3.75
2.00
4.00
2.00
4.00
36.25
43.75 33.13 5.25
2.50
4.00
37.00
43.75 33.13 5.88
2.50
4.00
DOWNBLAST
E
G
Net
Wheel
Roof
G Ø
Weight
Diameter
Opening
(lbs)
0.38
10.50
15.00
33
0.38
12.25
15.00
35
0.44
13.50
17.00
51 / 59
0.44
15.00
17.00
56 / 65
0.44
16.50
20.75
100 / 106
0.44
18.25
20.75
104 / 110
0.44
21.25
29.00
176
0.44
24.50
29.00
181
Page 1 of 6

Advertisement

loading

Summary of Contents for Canarm XSA Series

  • Page 1 XSA SERIES SPUN ALUMINUM EXHAUSTER OPERATION INSTRUCTIONS AND PARTS MANUAL READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions are intended to supplement good general practices and are not intended to cover detailed instruction procedures.
  • Page 2: Installation

    XSA SERIES SPUN ALUMINUM EXHAUSTERS INSTALLATION Install roof curb, caulk and flash to ensure the water tightness. Rotate the blower wheel by hand. Wheel should not be rubbing against the housing inlet. If rubbing occurs, loosen the set screws on the wheel hub and shift the wheel to obtain clearance.
  • Page 3 XSA SERIES SPUN ALUMINUM EXHAUSTERS EC (Electronically Controlled) MOTOR SPEED CONTROL EC motors are equipped with a control module that allows for accurate manual adjustment of motor speed. Motor speed range is from 300 to 1800rpm or maximum rpm for that model.
  • Page 4: Maintenance

    XSA SERIES SPUN ALUMINUM EXHAUSTERS UP-BLAST UL762 RESTAURANT EXHAUST INSTALLATION UP-BLAST WALL MOUNTED UL762 RESTAURANT EXHAUST INSTALLATION WALL DISCONNECT MOUNTED OUTSIDE OF THE HOUSING, WIRED THROUGH THE VENT TUBE BY OTHERS WALL MOUNT BRACKET (OPTIONAL) WIRED TO POWER VENTED CURB...
  • Page 5: Fan Troubleshooting

    XSA SERIES SPUN ALUMINUM EXHAUSTERS WARNING FAN TROUBLESHOOTING MAKE SURE THE UNIT IS NOT CAPABLE OF OPERATION DURING REPARATION. PROBLEM POSSIBLE ISSUE SOLUTION Adjust wheel, loosen set screw(s) and move the wheel, acquiring Wheel rubbing inlet clearance between inlet and wheel, then re-tighten set screw(s)
  • Page 6 XSA SERIES SPUN ALUMINUM EXHAUSTERS XSA SERIES SPUN ALUMINUM XSA SERIES SPUN ALUMINUM UPBLAST EXHAUSTERS - EXPLODED DOWNBLAST EXHAUSTERS - EXPLODED VIEW VIEW ITEM # DESCRIPTION ITEM # DESCRIPTION MOTOR WRAP TOP CAP MOTOR WRAP BEARING MOTOR SUPPORT PLATE MOTOR SUPPORT PLATE...

This manual is also suitable for:

Xsa105-udXsa120-udXsa135-udXsa135-ubXsa150-udXsa150-ub ... Show all