Your Sunbeam® Cool Mist humidifier draws dry air through the rear air intake grill area. This air is then passed through a moisture–laden wick filter, which retains the minerals and deposits in the water. The resulting moist air is directed back into the room from the top air grill.
NOTE: This humidification system provides a cool, invisible moisture output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%.
Your humidifier is equipped with a digital humidistat that allows you to set your humidifier to your desired comfort level. To preset a precise comfort level, turn the Toggle Switch to adjust the humidity level ranging from 30% to 60% or " " setting for constant humidity. Humidity will increase or decrease in increments of 5%. The LCD Display will show the selected humidity level for 3 seconds and then change back to show the room humidity. The Set humidity level will illuminate on top left of the LCD Display. When the room humidity level rises above the set humidity, the humidifier will stop. When the room humidity level drops below the set humidity, the humidifier will turn on automatically to maintain the preset humidity level.
NOTE: To shut the humidifier off at any setting, press the Power Button (). The humidistat has memory. This means that when you turn the unit back on, it will be at the last humidity setting before the humidifier is turned off. However, if the humidifier is unplugged, the digital humidistat will no longer remember the previous humidity setting. You will need to reset the digital humidistat if the humidifier is unplugged.
DO NOT move the humidifier with water in the tank or the humidifier base. The moving action of the water may activate the water tank's release nozzle and overfill the humidifier base. This may cause the humidifier to function intermittently, or stop emitting mist. Should this occurs, simply remove the excess water
NOTES:
Once the tank is empty, turn off your humidifier and unplug it from the electrical outlet. Before refilling, empty any residual water from the base and the tank (follow the daily maintenance instructions). Then follow the Filling Instructions to refill the tank and put back into the humidifier to begin operation.
Your humidifier is equipped with 24-Hour Auto Shut-off Timer feature. This allows you to program your humidifier to shut off automatically after running a defined time interval.
Through normal use, waterborne minerals and sediment become trapped in the wick filter. The harder your water, the greater the amount of minerals in the water, and the more often you will need to change your filter. You will be able to monitor the life of the filter in your humidifier by checking the FilterCheck® Indicator.
NOTE: After 60 minutes of use, FilterCheck® Indicator will move and indicate your filter condition. A brand new filter will register in the section reading GOOD filter. After frequent use of your humidifier, the FilterCheck® Indicator will let you know when the filters need to be changed, see Figure 3.
When the needle is in the CHANGE section, this means the proper amount of moisture is not getting into your air due to the excessive minerals and sediment that have become trapped on your filters. At this point, you should replace your filter. It is important to change your filter as indicated to obtain stated performance level.
To replace the filter, follow the steps below:
It will take about 30 minutes for the humidifier to reach maximum output.
NOTE: You can purchase replacement filters (model HWF100 / SF235) at a local retailer, by calling 1-888-264-9669, or by visiting www.sunbeam.com. It is recommended that a replacement filter is purchased for uninterrupted use.
Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.
In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.
NOTE: The Tray is dishwasher safe (TOP RACK ONLY) for easy cleaning.
To Remove Scale:
To Disinfect Humidifier Base and Tank:
When not using your humidifier for an extended period of time:
To order the replacement accessories you can do any of the following:
TROUBLESHOOTING | ||
TROUBLE | PROBABLE CAUSE | SOLUTION |
| Not plugged in. Outlet not functioning. | Plug in unit. Have outlet replaced by a licensed electrician. |
| Cool mist is invisible. The filter has not absorbed water. | Operate in High setting. Wait 30 minutes for filter to absorb water. |
| The filter has absorbed minerals. | Replace your filter (HWF100 / SF235) by calling 1-888 -264-9669, or visiting www.sunbeam.com |
| Takes 60 minutes to register. | Allow the humidifier to run continuously for 60 minutes for the FilterCheck ® Indicator to reflect the filter condition. |
| Humidity at the humidifier is at or below 25%. | Continue to operate humidifier to raise the room humidity. |
| Humidity at the humidifier is at or above 80%. | Stop operating the humidifier if the humidity level is too high. |
FREQUENTLY ASKED QUESTIONS | |
Question | Answer |
| The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as: Air exchange in the room where the humidifier is placed. Room construction of the room where the humidifier is placed. Temperature of the room where the humidifier is placed. Humidity levels in the room where the humidifier is placed. Movement of occupants and the opening and closing of doors in the room where the humidifier is placed. Home furnishings in the room where the humidifier is placed. |
| See Daily Maintenance instructions. Regular cleaning is recommended. |
| Run your unit on the lowest setting. If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time. Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time. |
If you have any questions regarding your product or would like to learn more about other Sunbeam® products, please contact our Consumer Service Department at 1-888-264-9669 or visit our website at www.sunbeam.com
© 2011 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All Rights Reserved.
Distributed by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions, Boca Raton, Florida 33431.