Lutron Electronics MTM-380SD Operation Manual
Lutron Electronics MTM-380SD Operation Manual

Lutron Electronics MTM-380SD Operation Manual

Sd card real time datalogger, 3 channels temperature monitor

Advertisement

SD card real time datalogger
3 Channels
TEMPERATURE MONITOR
Model : MTM-380SD
OPERATION MANUAL
Your purchase of this 3
C H A N N E L S
T E M P E R A T U R E
MONITOR
CARD
DATALOGGER
marks a step forward for
you into the field of
precision measurement.
A l t h o u g h
DATALOGGER
complex
and
instrument, its durable
structure
will
many years of use if
p r o p e r
o p e r a t i n g
t e c h n i q u e s
developed. Please read
t h e
f o l l o w i n g
instructions
and always keep this
manual
within
reach.
with
SD
t h i s
is
a
delicate
allow
a r e
carefully
easy

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTM-380SD and is the answer not in the manual?

Questions and answers

Summary of Contents for Lutron Electronics MTM-380SD

  • Page 1 SD card real time datalogger 3 Channels TEMPERATURE MONITOR Model : MTM-380SD Your purchase of this 3 C H A N N E L S T E M P E R A T U R E MONITOR with CARD DATALOGGER...
  • Page 2 TABLE OF CONTENTS 1. FEATURES................2. SPECIFICATIONS................ 3. FRONT PANEL DESCRIPTION..............3-1 Display..................3-2 Logger Button ( Enter Button )............... ▲ Button ( Time Button )............▼ Button................3-5 SET Button..................3-6 Hanging holes................3-7 Stand....................3-8 Battery cover/Battery compartment............. 3-9 Screw of the battery cover................
  • Page 3: Specifications

    1. FEATURES * Monitor with real time data logger, save the measuring data along the time information ( year, month, date, hour, minute, second ) into the SD memory card and can be down load to the Excel, extra software is no need. user can make the further data or graphic analysis by themselves.
  • Page 4 Datalogger 5/10/30/60/120/300/600 seconds Sampling Time or Auto. * Default sampling time is 60 seconds. * The " Auto " sampling . means when the measuring value is changed ( > ℃ ± 1 ) will save the data one time only. ≦...
  • Page 5 Weight 199 g/0.44 LB. Dimension 132 x 80 x 32 mm ( 5.2 x 3.1 x 1.3 inch ) Accessories * Instruction manual......1 PC Included * Type K Temp. probe, TP-01....1 PC * Hanging unit ( with sticker )....1 PC Optional SD Card ( 2 GB )
  • Page 6: Front Panel Description

    3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-2 Logger button ( Enter button ) ▲ Button ( Time Button ) ▼ Button 3-5 SET Button 3-6 Hanging holes 3-7 Stand 3-8 Battery cover/Battery compartment 3-9 Screw of the battery cover 3-10 T1 Temp.
  • Page 7: Measuring Procedure

    4. MEASURING PROCEDURE 1) Install the batteries into the battery compartment : * Loose the " Screw of the battery cover " ( 3-9, Fig. 1 ) and take away the " Battery Cover " ( 3-8, Fig. 1 ) from the meter.
  • Page 8: Data Logger

    5. DATALOGGER 5-1 Preparation before execute datalogger function a. Insert the SD card Prepare a " SD memory card " ( 1 GB to 16 GB, optional ), insert the SD card into the " SD card socket " ( 3-16, Fig. 1) with the correct direction exactly.
  • Page 9 e. 3 Information of LCD display * If the Display show : It means that the SD card exist the problem or the SD card memory is full, it should CArd change SD memory card. * If the Display show : It means that the battery is low voltage.
  • Page 10 Remark : How to set the sampling time, refer to Chapter 7-3, page 13. How to set the beeper sound is enable, refer to Chapter 7-4, page 13. b. Finish the Datalogger During execute the Datalogger function ( Display show the "...
  • Page 11 5-4 SD Card Data structure 1) When the SD card is used into the meter, the SD card When the first time, the SD card is used into the meter, the SD card will generate a folder : TMC01 2) If the first time to execute the Datalogger, under the route TMC01\, will generate a new file name TMC01001.XLS.
  • Page 12 6. Saving data from the SD card to the computer ( EXCEL software ) 1) After execute the Data Logger function, take away the SD card out from the " SD card socket " ( 3-16, Fig. 1 ). 2) Plug in the SD card into the Computer's SD card slot ( if your computer build in this installation ) or insert the SD card into the "...
  • Page 13: Advanced Setting

    EXCEL graphic screen ( for example ) 7. ADVANCED SETTING Under do not execute the Datalogger function, press the " SET button " ( 3-5, Fig. 1 ) > 2 seconds continuously will enter the " Setting " mode., then release the " SET button ". Following press the "...
  • Page 14 Remark : During execute the " Setting " function, if within 5 seconds , do not press any buttons further, the LCD Display will return to normal screen. 7-1 SD memory card Format When the Display show " Sd F " ▲...
  • Page 15 Remark : The adjusted unit will be flashed. 2) After set all the time value ( Year, Month, Date, Hour, Minute, Second ), press the " SET button " ( 3-5, Fig. 1 ) once will save the time value, then the screen will jump to Sampling time "...
  • Page 16 yES - Meter's beep sound will be ON with default when save each data. no - Meter's beep sound will be OFF with default. when save each data. 2) After select the upper text to " yES " or " no ", press the "...
  • Page 17 ℃ ℉ 7-6 Select the Temp. unit to When the Display show " t-CF " ▲ ▼ 1) Use the " Button " ( 3-3, Fig. 1 ) or " Button " ( 3-4, Fig. 1 ) to select the upper Display text to " C " or "...
  • Page 18: Power Supply From Dc Adapter

    8. POWER SUPPLY from DC ADAPTER The meter also can supply the power supply from the DC 9V Power Adapter ( optional ). Insert the plug of Power Adapter into " DC 9V Power Adapter Input Socket " ( 3-13, Fig. 1 ). 9.
  • Page 19: Rs232 Pc Serial Interface

    11. RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3.5 mm terminal ( 3-15, Fig. 1 ) if the RS232 function already select to " ON ", refer to chapter 7-7, page 15. The data output is a 16 digit stream which can be utilized for user's specific application.
  • Page 20 Decimal Point(DP), position from right to the left 0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP Polarity 0 = Positive 1 = Negative D11 & D12 Annunciator for Display ℃ ℉ = 01 = 02 When send the up display data = 1 When send the middle display data = 2...
  • Page 21 13. PATENT The meter ( SD card structure ) already get patent or patent pending in following countries : Germany Nr. 20 2008 016 337.4 JAPAN 3151214 TAIWAN M 358970 M 359043 CHINA ZL 2008 2 0189918.5 ZL 2008 2 0189917.0 Patent pending 0911-MTM380SD...

Table of Contents